background image

Installation manual

Daikin Altherma low temperature monobloc control box

English

Installation manual

Daikin Altherma low temperature monobloc control

box

EKCB07CAV3

Summary of Contents for EKCB07CAV3

Page 1: ...Installation manual Daikin Altherma low temperature monobloc control box English Installation manual Daikin Altherma low temperature monobloc control box EKCB07CAV3 ...

Page 2: ...ntům u skladu sa slijedećim standardom ima ili drugim normativnim dokumentom ima uz uvjet da se oni koriste u skladu s našim uputama 16 17 18 19 20 21 22 23 24 25 megfelelnek az alábbi szabvány ok nak vagy egyéb irányadó dokumentum ok nak ha azokat előírás szerint használják spełniają wymogi następujących norm i innych dokumentów normalizacyjnych pod warunkiem że używane są zgodnie z naszymi instr...

Page 3: ...ral safety precautions Safety instructions that you must read before installing Paper in the box of the outdoor unit Outdoor unit installation manual Installation instructions Paper in the box of the outdoor unit Control box installation manual Installation instructions Paper in the box of the control box Option box installation manual Installation instructions Paper in the box of the option box B...

Page 4: ... power supply voltage free contact 2 d 5 Backup heater kit thermistor 2 e 6 Backup heater kit thermal protector 2 e 7 Backup heater kit connection from control box 2 3V3 3 6V3 6W1 9W1 e Item Description Wires Maximum running current 8 3 way valve 3 f 9 Power supply for booster heater and thermal protection from control box 4 GND a 10 Power supply for booster heater to control box 2 GND 13 A 11 Dom...

Page 5: ... use multicore cable for power supply cables 4 3 1 About electrical compliance Equipment complying with EN IEC 61000 3 12 European International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low voltage systems with input current 16 A and 75 A per phase 4 3 2 To connect the electrical wiring on the control box 1 Insert the wiring from the bot...

Page 6: ...user interface cable to control box terminals X2M 20 21 Route the cable from the right hand side of the terminals fasten it to the cable tie mountings and route it through the hole of the low voltage wiring Onto control box In the room 2 Connect the control box to the outdoor unit Fix the cable with cable ties to the cable tie mountings X5M 20 21 1 2 X2M 3 Insert a screwdriver into the slots under...

Page 7: ...4C From the top a b PCB b 1 4D From the top centre a PCB b b 1 a Notch this part for the wiring to pass through with nippers etc b Secure the wiring to the front part of the casing using the wiring retainer and clamp 5 Starting up the system For instructions on how to configure and commission the system and hand it over to the user refer to the installation manual of the outdoor unit ...

Page 8: ...4P404075 1 2015 03 Copyright 2015 Daikin ...