background image

FDXS25CVMA FDXS35CVMA
FDXS50CVMA FDXS60CVMA
CDXS25CVMA CDKS25CVMA
CDXS35CVMA CDKS35CVMA
CDXS50CVMA CDKS50CVMA
CDXS60CVMA CDKS60CVMA

MODELS

DAIKIN ROOM AIR CONDITIONER

Operation Manual

00_CV_3P141308-7H.fm  Page 1  Tuesday, June 6, 2006  9:25 AM

Summary of Contents for CDXS25CVMA

Page 1: ...FDXS25CVMA FDXS35CVMA FDXS50CVMA FDXS60CVMA CDXS25CVMA CDKS25CVMA CDXS35CVMA CDKS35CVMA CDXS50CVMA CDKS50CVMA CDXS60CVMA CDKS60CVMA MODELS DAIKIN ROOM AIR CONDITIONER Operation Manual ...

Page 2: ...ts 4 Preparation Before Operation 7 OPERATION AUTO DRY COOL HEAT FAN Operation 10 POWERFUL Operation 12 OUTDOOR UNIT SILENT Operation 13 HOME LEAVE Operation 14 TIMER Operation 16 Note for Multi System 18 CARE Care and Cleaning 20 TROUBLE SHOOTING Trouble Shooting 22 ...

Page 3: ...t of the repairs with our service staff Do not attempt to install the air conditioner by your self Incorrect work will result in water leakage electric shocks or fire For installation consult the dealer or a qualified technician In order to avoid electric shock fire or injury if you detect any abnormally such as smell of fire stop the operation and turn off the breaker And call your dealer for ins...

Page 4: ...not place objects in direct proximity of the outdoor unit and do not let leaves and other debris accumulate around the unit Leaves are a hotbed for small animals which can enter the unit Once in the unit such animals can cause malfunc tions smoke or fire when making contact with electrical parts Do not operate the air conditioner with wet hands Do not wash the indoor unit with excessive water only...

Page 5: ...4 Names of parts Indoor Unit 3 6 8 9 10 7 1 4 5 2 ...

Page 6: ...p yellow page 16 9 HOME LEAVE lamp red Lights up when you use HOME LEAVE operation page 14 10 Indoor Unit ON OFF switch Push this switch once to start operation Push once again to stop it This switch is useful when the remote controller is missing The operation mode refers to the following table Outdoor Unit 11 Air inlet Back and side 12 Refrigerant piping and inter unit cable 13 Drain hose 14 Ear...

Page 7: ... ON OFF button Press this button once to start operation Press once again to stop it 7 MODE selector button It selects the operation mode AUTO DRY COOL HEAT FAN page 10 8 SILENT button OUTDOOR UNIT SILENT operation page 13 9 FAN setting button It selects the air flow rate setting 10 ON TIMER button page 17 11 OFF TIMER button page 16 12 TIMER Setting button It changes the time setting 13 TIMER CAN...

Page 8: ...together When the system is not used for a long time take the batteries out We recommend replacing once a year although if the remote controller display begins to fade or if reception deteriorates please replace with new alkali batteries Do not use manganese batteries The attached batteries are provided for the initial use of the system The usable period of the batteries may be short depending on ...

Page 9: ...lder to a wall a pillar etc with the screws supplied with the holder 3 Place the remote controller in the remote controller holder ATTENTION About remote controller Never expose the remote controller to direct sunlight Dust on the signal transmitter or receiver will reduce the sensitivity Wipe off dust with soft cloth Signal communication may be disabled if an electronic starter type fluorescent l...

Page 10: ...operating If you are not going to use the air conditioner for a long period for example in spring or autumn turn the breaker OFF Use the air conditioner in the following conditions Operation outside this humidity or temperature range may cause a safety device to disable the system 1 3 2 Recommended temperature setting For cooling 26 C 28 C For heating 20 C 24 C Mode Operating conditions If operati...

Page 11: ...essing of the button advances the mode setting in sequence AUTO DRY COOL HEAT FAN 2 Press ON OFF button The OPERATION lamp lights up To stop operation 3 Press ON OFF button again Then OPERATION lamp goes off To change the temperature setting 4 Press TEMPERATURE adjustment button DRY or FAN mode AUTO or COOL or HEAT mode The temperature setting is not variable Press to raise the temperature and pre...

Page 12: ... operation frost may occur on the outdoor unit and lower the heating capacity In that case the system switches into defrosting operation to take away the frost During defrosting operation hot air does not flow out of indoor unit Note on COOL operation This air conditioner cools the room by blowing the hot air in the room outside so if the outside temperature is high performance drops Note on DRY o...

Page 13: ...tion POWERFUL Operation cannot be used together with SILENT Operation Priority is given to the function of whichever button is pressed last POWERFUL Operation can only be set when the unit is running Pressing the operation stop button causes the settings to be canceled and the disappears from the LCD In COOL and HEAT mode To maximize the cooling heating effect the capacity of outdoor unit must be ...

Page 14: ...n If using a multi system this function will work only when the OUTDOOR UNIT SILENT operation is set on all operated indoor units However if using priority room setting see Note for multi system page 18 This function is available in COOL HEAT and AUTO modes This is not available in FAN and DRY mode POWERFUL operation and OUTDOOR UNIT SILENT operation cannot be used at the same time Priority is giv...

Page 15: ...ng HOME LEAVE operation for the first time please set the temperature and air flow rate for HOME LEAVE operation Record your preferred temperature and air flow rate 1 Press HOME LEAVE button Make sure is displayed in the remote control display 2 Adjust the set temperature with or as you like 3 Adjust the air flow rate with FAN setting button as you like Home leave operation will run with these set...

Page 16: ... comfortably air conditioned room Push the HOME LEAVE Operation button again and the air conditioner will adjust capacity to the set temperature for normal operation Set the unit to HOME LEAVE Operation before leaving the living room when going to bed The unit will maintain the temperature in the room at a comfortable level while you sleep When you enter the living room in the morning the temperat...

Page 17: ...er button changes the setting rapidly 3 Press OFF TIMER button again The TIMER lamp lights up To cancel the OFF TIMER operation 4 Press CANCEL button The TIMER lamp goes off NOTE When TIMER is set the present time is not displayed Once you set ON OFF TIMER the time setting is kept in the memory The memory is canceled when remote controller batteries are replaced When operating the unit via the ON ...

Page 18: ...er button changes the setting rapidly 3 Press ON TIMER button again The TIMER lamp lights up To cancel ON TIMER operation 4 Press CANCEL button The TIMER lamp goes off To combine ON TIMER and OFF TIMER A sample setting for combining the two timers is shown below ATTENTION In the following cases set the timer again After a breaker has turned OFF After a power failure After replacing batteries in th...

Page 19: ...ogramming during installation Please consult your retailer or dealer for assistance NIGHT QUIET Mode reduces the operation noise of the outdoor unit during the night time hours to prevent annoyance to neighbors The NIGHT QUIET Mode is activated when the temperature drops 5 C or more below the highest temperature recorded that day Therefore when the temperature difference is less than 5 C this func...

Page 20: ... If the unit in Room A enters POWERFUL operation operation capacity will be concentrated in Room A In such a case the cooling heating efficiency of the units in Rooms B C and D may be slightly reduced 3 Priority when using OUTDOOR UNIT SILENT operation Example Room A is the Priority Room in the examples Just by setting the unit in Room A to SILENT operation the air conditioner starts OUTDOOR UNIT ...

Page 21: ...hrinking or deformation After cleaning dry them in the shade 3 Replacing the air filter Rear suction Hook the filter behind the flap situated at the top of the unit and push the other side gently over the 3 bends Bottom suction Hook the filter behind the flap situated at the middle of the unit and push the other side gently over the 3 bends Only a qualified service person is allowed to perform mai...

Page 22: ...fan operation page 18 Do not operate the air conditioner without filters this to avoid dust accummulation inside the unit Do not remove the air filter except when cleaning Unnecessary handling may damage the filter Do not use gasoline benzene thinner polishing powder liquid insecticide It may cause discoloring or warping Do not let the indoor unit get wet It may cause an electric shock or a fire O...

Page 23: ...onditioner is in defrost operation In COOL or DRY mode Moisture in the air condenses into water on the cool surface of outdoor unit piping and drips Mist comes out of the indoor unit This happens when the air in the room is cooled into mist by the cold air flow during cooling operation The indoor unit gives out odour This happens when smells of the room furniture or cigarettes are absorbed into th...

Page 24: ... and the outdoor units Clean the air filters or take all obstacles away and turn the breaker OFF Then turn it ON again and try operating the air conditioner with the remote controller If the lamp still blinks call the service shop where you bought the air conditioner Are operation modes all the same for indoor units connected to outdoor units in the multi system If not set all indoor units to the ...

Page 25: ...ay get foul after several seasons of use resulting in poor performance It is recommended to have periodical maintenance by a specialist aside from regular cleaning by the user For specialist maintenance contact the service shop where you bought the air conditioner The maintenance cost must be born by the user Call the service shop immediately After a power failure The air conditioner automatically...

Page 26: ... 0607 HT 3P141308 7H M06B022 ...

Reviews: