Page 1: ...Installation Instructions Discovery Touch Control Induction Cooktop Models DYTT305N and DYTT365N Part No 109374 Rev A...

Page 2: ...efore you begin the installation process Leave these installation instructions with the customer Customer Keep these installation instructions for future reference and the local electrical inspector s...

Page 3: ...sis Doing so may cause a fire hazard During after use do not touch or let clothing or flammable materials touch the cooktop until it has cooled sufficiently Do not let anyone use the cooktop without k...

Page 4: ...luding above and below the cooktop Do not hang flammable or heat sensitive objects over the cooktop If the cooktop is near a window do not use window treatments that could blow over the cooktop and cr...

Page 5: ...be accessible when the cooktop is in place Location Requirements Dacor recommends installing a non combustible material on the wall behind the cooktop To avoid a fire hazard do not install the cooktop...

Page 6: ...installing a range hood above the cooktop The hood should cover the cooktop entire surface and proj ect at least 5 inches beyond the bottom of any overhead cabinets Miscellaneous Installation This sec...

Page 7: ...face Cooking surface overhangs the top of the chassis by 3 4 1 9 cm in front back and on both sides Appliance Dimensions All tolerances 1 16 1 6 mm unless otherwise stated This section contains pertin...

Page 8: ...tion 3 does not apply 4 1 1 8 2 9 cm min to combustible surface at rear 3 4 1 9 cm min to non combustible surface at rear 5 Ensure internal space allows proper under cabinet ventilation for cooktop ch...

Page 9: ...5 8 1 6 cm DYTT365 cooktop w RV36 downdraft 34 3 4 88 3 cm 33 3 4 85 7 cm Countertop Inset Cutout Dimensions IMPORTANT Inset Cutout See the previous page for minimum clearances to com bustibles and ov...

Page 10: ...d 2 Feed the appliance conduit into the junction box and attach it using a UL certified strain relief 3 According to local codes use one of the two methods shown on the next page to connect the applia...

Page 11: ...wire to a grounded cold water pipe use a separate copper grounding wire 10 min and a clamp with an external grounding screw The grounded cold water pipe must have metal con tinuity to an electrical gr...

Page 12: ...button The cook zone ON indicator goes out the cook zone is turned off WARNING If the cook zone HOT indicator has appeared it will stay on until the cook zone is safe to touch without causing a burn i...

Page 13: ...11 Wiring Diagrams...

Page 14: ...12 Wiring Diagrams...

Page 15: ...13 Notes...

Page 16: ...Dacor 14425 Clark Avenue City of Industry CA 91745 Phone 800 793 0093 Fax 626 403 3130 www dacor com...