SPX-7400_MAN_082112

SPX-7400 Series

Suprex® Reader Extender - Fiber Optic Interface

Operations Manual

SPX-7400 shown with EXP-2000

Содержание Suprex SPX-7400 Series

Страница 1: ...SPX 7400_MAN_082112 SPX 7400 Series Suprex Reader Extender Fiber Optic Interface Operations Manual SPX 7400 shown with EXP 2000 ...

Страница 2: ...ifications Module connections utilize standard ST style connections NOTE Single Mode or Multi Mode must be Specified at time of order SPX 7400 Multimode Loss Budget 13 dB 850 nm 62 5 125 Fiber Loss Budget 9 dB 850 nm 50 0 125 Fiber SPX 7410 Single mode Loss Budget 20 dB 1300 nm 9 125 Fiber Physical SPX 7400 Aluminum Enclosure 4 45 x 3 08 x 2 0 Each Unit SPX 7400 Aluminum Enclosure 4 45 x 3 08 x 2 ...

Страница 3: ...0 644 Strobed Rising Mag Tek Strobed Falling Edge Reserved F2F x ON 1 2 3 4 5 6 7 8 Dip switch 4 is ON Enable Pullup resistors Dip switch 4 is OFF Disable Pullup resistors DIP Switch 1 OFF See appendix for Expansion module Setup Remote Unit Settings 1 8 to 16 VDC In 2 Ground Status LED 1 exp 2 exp 3 5 VDC out 4 Prog Res 4 5 Prog Res 3 6 LED In 7 D1 Data out 8 D0 Clk out 1 Relay 2 N O 2 Relay 2 Com...

Страница 4: ...Access Control Panel 8 to 16 VDC Ground Diagnostic LED R1 Input Controls Strike on Remote R1 IN LED In D1 Data Out D0 Clock Out Card Reader DC Power Supply R1 N O R1 Com R1 N C Door Strike Output 8 to 16 VDC Ground Diagnostic LED LED Out D1 Data In D0 Clock In See page 10 for other strike control options ...

Страница 5: ...Fiber Optic Connections Fiber Optic Interface SPX 7400 Central Fiber Optic Interface SPX 7400 Remote TX RX TX RX ...

Страница 6: ...ting curve The Suprex units should be operated with a filtered 12 Volt nominal DC supply Any voltage between 8 and 16 volts can be utilized by following the temperature voltage derating curve Voltage should not exceed 16 VDC under normal operating conditions Temperature Rating vs Voltage Derating Curve ...

Страница 7: ...Cypress Suprex SPX 7400 Enclosure Dimensions 1 70 2 00 3 08 0 80 0 80 3 15 4 45 ø0 20 X 4 ...

Страница 8: ...ch a jumper wire from the Ground connection the the Relay 1 input on the Central unit Relay 1 on the Remote unit should activate with an audible click A VOM or continuity tester should show the Relay 1 normally open contacts on the Remote unit closing when the Relay 1 input is activated connected to ground on the Central unit 6 Units are shipped from the factory set for the Wiegand data format If ...

Страница 9: ...uminated on the unit s then the unit is not getting power or there is an electrical problem The Diagnostic LED s will be illuminated Red Green or flashing whenever power is applied CENTRAL UNIT FLASHING BETWEEN RED GREEN With power applied and no communication path between the Remote and Central the Central unit will flash the diagnostic indicator alternately between Red and Green REMOTE UNIT ILLU...

Страница 10: ...e two relays available for accessory outputs at the Remote end Either relay can be used to provide the Door Strike or Gate activation function This example uses Relay 1 Wiring Example Door Strike Follows LED Access Control Panel LED In R1 IN R1 Input Controls Strike on Remote Suprex Central Ground LED Signal Ground Only Relay and LED Connections are shown for clarity refer to previous diagrams for...

Страница 11: ...hing connected the associated output will be set to a high level When the input is set to 0Volts Ground the input will activate its associated output All Accessory outputs are Open Collector type and will switch to Ground when activated Each input will have an associated output See the following pages for a diagram of each I O pair Inputs can be tested by making a jumper connection to ground and m...

Страница 12: ...row denotes direction of command signal Relay 1 IN Input Signal Relay 1 N O Relay 1 Com Relay 1 N C Contact Outputs Suprex Central Suprex Remote Relay 2 N O Relay 2 Com Relay 2 N C Contact Outputs Relay 2 IN Input Signal Suprex Central Suprex Remote ...

Страница 13: ... units Relay 3 is activated when power is applied and the communication link between the Central and Remote is functioning Relay 3 will become deactivated Alarm condition when either the Relay 3 input on the remote is active OR the Remote unit is unable to communicate with the Central unit See APP NOTE FOR DETAILS Relay 4 N O Relay 4 Com Relay 4 N C Suprex Remote Contact Outputs Relay 4 IN Input S...

Страница 14: ...hese resistance values locally at the panel so that the correct supervised status is maintained At the same time the Remote unit must maintain supervision of the wires connected to the relays and switches that are connected to the remote access point The contact supervision is provided by the Remote unit The Suprex system does this by comparing the value of programming resistor at the Central unit...

Страница 15: ...ration The Expansion units are addressed and added to the system as pairs 5 Connect the Expansion modules into the system as indicated in this wiring diagram Operation with Expansion Modules The SPX 7400 system Remote and Central gateway units will operate as a standard pair Suprex units all of the I O and data terminals are available for use with readers and access control systems There are some ...

Страница 16: ...Link Multi drop Card Reader EXP 2000R 2 Door Parking Gate Cypress Suprex LYNK Fiber Optic Solution EXP 2000R 3 SPX 74X0C 1 EXP 2000C 3 ACS Fiberoptic Link EXP 2000R 4 EXP 2000R 8 SPX 74X0R 1 EXP 2000C 8 EXP 2000C 2 EXP 2000C 4 ...

Страница 17: ...m RLY3 N C RS232 Out RS232 In Ground Aux Out Relay2 Input Relay1 Input Access Control Panel R1 Input Controls Strike on Remote DC Power Supply Additional EXP Modules 8 to 16 VDC Ground EXP EXP LED In D1 Data Out D0 Clock Out R1 IN SPX XXXX Central See EXP 2000 Manual for further setup instructions Cypress Suprex Series Wiegand Expansion Module Panel Central interface ...

Страница 18: ... RLY2 N C RLY1 N O RLY1 Com RLY1 N C RS232 Out RS232 In Ground Aux In N C N C 485 485 5 VDC Out RLY4 Input 5V RLY3 Input 5V LED Output D1 Data F2F Input D0 CLK Input DC Power Supply Card Reader EXP EXP LED Out D1 Data In D0 Clock In 8 to 16 VDC In Ground SPX XXXX Remote R1 N O R1 Com R1 N C Door Strike Output See EXP 2000 Manual for further setup instructions ...