Value600EI/800EI/1000EI 

User’s Manual 

K01-C000014-00

 

 

SAFETY WARNINGS   

  (SAVE THESE INSTRUCTIONS)

 

This manual contains important safety instructions. Please read and follow all instructions carefully 

during installation and operation of the unit. Read this manual thoroughly before attempting to unpack, 

install, or operate your UPS. 

 

CAUTION!

 To prevent the risk of fire or electric shock, install in a temperature and humidity controlled 

indoor area free of conductive contaminants. (See the specifications for the acceptable temperature and 

humidity range.) 

CAUTION!

 To reduce the risk of overheating the UPS, do not cover the UPS' cooling vents and avoid 

exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space 

heaters or furnaces. 

CAUTION!

 Do not attach non-computer-related items, such as medical equipment, life-support 

equipment, microwave ovens, or vacuum cleaners to UPS. 

CAUTION!

 Do not plug the UPS input into its own output. 

CAUTION!

 Do not allow liquids or any foreign object to enter the UPS. Do not place beverages or any 

other liquid-containing vessels on or near the unit. 

CAUTION!

 In the event of an emergency, press the OFF button and disconnect the power cord from the 

AC power supply to properly disable the UPS. 

CAUTION!

 Do not attach a power strip or surge suppressor to the UPS. 

CAUTION!

 Unplug the UPS prior to cleaning and do not use liquid or spray detergent. 

CAUTION!

 Servicing of batteries should be performed or supervised by personnel knowledgeable of 

batteries and the required precautions. Keep unauthorized personnel away from batteries. 

CAUTION!

 The battery supply should be therefore disconnected in the plus and minus pole at the quick 

connectors of the battery when maintenance or service work inside the UPS is necessary. 

CAUTION!

 Internal battery voltage is 12Vdc. Sealed, lead-acid, 6-cell battery. 

CAUTION!

 When replacing the batteries, use the same number and type of batteries. 

CAUTION!

 Do not dispose of batteries in a fire. The battery may explode. Do not open or mutilate the 

battery or batteries. Released electrolyte is harmful to the skin and eyes. 

CAUTION!

 A battery can present a risk of electric shock and high short circuit current. The following 

precaution should be observed before replacing batteries: (1) Remove watches, rings, or other metal 

objects.(2) Use tools with insulated handles.(3) Wear rubber gloves and boots.(4) Do not lay tools or 

metal parts on top of batteries. (5) Disconnect charging source prior to connecting or disconnecting 

batteries terminal. 
 

INSTALLING YOUR UPS SYSTEM   

 
UNPACKING 

 

Inspect the UPS upon receipt. The box should contain the following: 

(1)UPS Unit

1; (2)Power Cord

1; (3)USB Cable

1; (4)User Manual

1; (5)Management Ssoftware 

Disk

 

HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT 

 

1.  Insure that the equipment plugged into the battery power-supplied outlets does not exceed the UPS 

unit’s rated capacity (600VA/360W for Value600EI; 800VA/480W for Value800EI; 1000VA/550W for 

Value1000EI). If rated unit capacities are exceeded, an overload condition may occur and cause the 

UPS unit to shut down or the fuse blow. 

 

2.  If the power requirements of your equipment are listed in units other than Volt-Amps (VA), convert 

Watts (W) or Amps (A) into VA by doing the calculations below. Note: The below equation only 

calculates the maximum amount of VA that the equipment can use, not what is typically used by the 

equipment at any one time. Users should expect usage requirements to be approximately 60% of 

below value. 

 

TO ESTIMATE POWER REQUIREMENTS 

 

1.              Amps (A) x 230 =                VA 

 

 

2. Add the totals up for all pieces of equipment and multiply this total by 0.6 to calculate actual 

requirements. There are many factors that can affect the amount of power that your computer system 

will require. The total load that you will be placing on the battery-powered outlets should not exceed 

80% of the unit’s capacity. 

 

HARDWARE INSTALLATION GUIDE 

 

Before installation, please read and understand the following instructions: 

 

 

1. 

Placement 

The UPS must be installed in a protected environment away from heat- emitting appliances such 

as a radiator or heat register. Do not install this product where excessive moisture is present. 

 

 

 

2. 

Ventilation 

The location should provide adequate air flow around the UPS with one inch minimum clearance 

on all sides for proper ventilation. 

 

3. 

Charge the Battery 

Your new UPS may be used immediately upon receipt. However charge loss may occur during 

shipping and storage. So charging the battery for at least 8 hours is recommended to insure that 

the battery is fully charged. (To recharge the battery, simply leave the unit plugged into an AC 

outlet.)   

This UPS can be charged even when UPS is not turn on

.

 

 

4. 

Connect to AC 

Connect the UPS to a wall outlet. Please avoid   

using extension cords and adapter plugs. (To   

maintain optimal battery charge, leave the UPS   

plugged in at all times.)

 

 

5. 

Connect the Load 

Connect the equipment to your UPS outlets.

 

Items   

such as copiers, laser printers, vacuums, space   

heaters, or other large electrical devices SHOULD   

NOT be connected to the UPS.

 Please make sure   

that the total loads of your equipments are less than   

the maximum total power load of your UPS. 

           

 

6. 

Connect to Computer: 

Install your software and accessories. To use the software, simply use the enclosed serial interface 

or USB cable to connect the UPS unit and your computer. 

 

BASIC OPERATION 

 

FRONT PANEL DESCRIPTION 

 

 

 

 

 

 

 

 

 

 

 
 

1. 

Power On Indicator 

This LED is illuminated when the utility condition is normal and the UPS outlets are providing “clean 

power”, free of surges and spikes. 

 

2. 

Power Switch 

Press the power switch to turn the UPS ON or OFF. 

 

 

REAR PANEL DESCRIPTION 

 

 

 

 

 

 

 

 

 

 
 
 
1. 

AC Inlet   

Connect to utility power through the input power cord.

   

 

2. 

Input Fuse 

The

 

fuse provides optimal overload protection. 

 

3. 

AC outlet 

The UPS provides outlets for connected equipment to insure temporary uninterrupted operation 

during a power failure and against surges and spikes. 

 

 

Reviews: