background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

CMX01 

User Manual 

 
 
 
 
 
 
 
 
 
 

 

 
3350 Ridgeway Drive, Unit 3, Mississauga, Ontario L5L 5Z9 
www.cranepi.com 
Tel: 1-800-499-6191 

 

Copyright © 2022 Cummins Allison ULC 

Summary of Contents for CMX01

Page 1: ...CMX01 User Manual 3350 Ridgeway Drive Unit 3 Mississauga Ontario L5L 5Z9 www cranepi com Tel 1 800 499 6191 Copyright 2022 Cummins Allison ULC ...

Page 2: ...lterations or any other changes on the product are not allowed without the permission of the manufacturer The warranty applies provided the product has been handled properly for its intended use and in accordance with the user manual Table of Contents Introduction and Intended Use 3 Safety Information 3 Warnings 3 Front Rear View 4 User Interface 5 Installation 6 Bag Box Installation 7 Setting the...

Page 3: ...arked on the product Do not install or use this device outdoors near water or when you are wet Install the product securely on a stable surface See also chapter Installation Never exceed the specified load of the bags as itemized in this manual Failure to do so may result in damage and or user injury Do not touch the coin disc when it is in operation Use best practice Take extra care of long hairs...

Page 4: ... 499 6191 Front Rear View Display Keyboard Right top cover service access Count exit with Quick change switch Coin Guide Coin disc Coin thickness adjuster Coin diameter adjuster Reject exit Coin tray support rod Foot pedal connector Printer port RS232 Device S N label Carry handle Power cord socket Main Switch ...

Page 5: ...number Number of coins in bag Function keys Denomination in Value mode Key Chart Key Description Normal key stroke 3 seconds key stroke Start Stop Start or stop counting Add to memory Add the count to memory Print Print ticket Set Batch Set batch stop Clear bag content Clear Deletes count result and bag content Deletes memory Denomination Select new denomination or coin number Show memory total Se...

Page 6: ...g The main fuse protection must be minimum 1 5A Install the CMX01 where no one can step on it or trip over the line cord and the line cord cannot be damaged The seating area must be stable solid and smooth The bagging unit of the machine must protrude the table edge so that the connected bag hangs freely But ensure the front feet of the CMX01 remain in fully resting on the table work surface Rejec...

Page 7: ... be also used for the optional tubing kit On the reject exit a cup or a bagging unit can be attached When using the reject bagging unit the CMX01 must be placed on the left side of the desk so the reject bag hangs freely Warning of possible device tilting Do not exceed the weight of 9 kg about 1000 x 25 coins in the counting bag and 7 kg about 800 x 25 coins in the reject bag Connect the reject cu...

Page 8: ...er Thickness adjuster Manual Adjustment for Token Counting Thickness Open the right top cover Turn the Thickness adjuster to maximum Place the token under the thickness block and turn the adjuster slowly down until it gently touches the token Turn the adjuster backward until the token moves freely without resistance between disc and thickness block Thickness Thickness Diameter Diameter Diameter Li...

Page 9: ...g Press On Off key to start the count or push the coin exit to activate the Quick change switch The CMX01 shows the counted quantity or value When the count is finished the CMX01 stops automatically You can also press On Off or push again the coin exit to stop the count manually Piece counting Value counting or It is now possible to RM Print the count M Save the count into the memory C clear the c...

Page 10: ... coin number will not change After the last coin number 9 a total symbol Σ appears It represents the sum of all saved counts and cannot be used for counting Memory Add Memory The CMX01 adds automatically full bags to the memory When a count is finished and a bag stop is not reached it is possible to accumulate the count to the memory by pressing M After pressing M the Count Value is reset to 0 B1 ...

Page 11: ...ew stop between 0 99999 Press M to save the new stop Alternative standard batch numbers 500 1000 2000 5000 10000 can be used by pressing B several times B enter new stop M If you change a bag stop and the bag content is not zero there will be a warning message Do you want to clear count and bag Press 1 Yes to clear the two counters or 2 No to count further without clearing Note A steady stop in Ba...

Page 12: ... System Setting Currently there are three sub menus available 10 45 Alarm signal On Date Time Factory Default 0 1 2 Alarm signal ON beep always Off no beep Error beep only by error Date Time Enter numbers with numeric keypad and press On Off to save and exit Factory Default Press 2 and confirm with 1 to reset all settings e g denom values and bag stops Screen Display Press 2 to switch between blac...

Page 13: ... here Use the 0 key to move the selection highlighted bar down and use the 1 key to move the highlighted bar left or right to select an item you want to change Press the 2 key to Enter the selected value to change it Press M to set the value or batch to the correct setting Example 0025 for 0 25 coin Press the M to save the value Note if a mistake is made you can press C which will clear the value ...

Page 14: ...performance and error free operation cleaning must be performed regularly The higher the usage the more frequent cleaning maintenance CAUTION Always turn off and unplug the power cord before maintaining the CMX01 Daily cleaning Remove the dirt from the coin track Wipe the dust away under the counting sensor Use a soft brush and a lint free cloth ...

Page 15: ...up the transport belt Clean the count sensor and remove jammed objects Control the coin diameter setting Enter denom value before There is no value configured for the selected denomination Select another denomination or enter a value in the Denom Batch setting menu Motor does not start w o error message The total memory is selected Select a denomination with the 1 key Please empty the bag When cle...

Page 16: ...e Product type CMX01 Serial number to which this declaration relates is in conformity with the following standards Low Voltage Directive 2014 35 EU EMC Directive 2014 30 EU Applied harmonized standards EN55022 2010 AC 2011 EN61000 3 2 2014 EN61000 3 3 2013 EN55024 2010 EN60950 1 2006 A11 2009 A1 2010 A12 2011 A2 2013 Date of issue 13th of May 2015 Place of issue Mörfelden Walldorf Signed by Name P...

Page 17: ...ns per minute Acousticnoise level LpA 79 dB A Uncertainty 2 LpA Standby 1 dB A Chute hopper capacity 1 500 coins Operating temperature 10 C to 35 C 50F 95F Start Stop On Off key Quick change switch Foot pedal Operating humidity 20 to 80 RH non condensing Bag stop 2 levels 0 99 999 coins Individual stop per denom Dimensions Height Depth Width mm with closed chute 190 350 235 Memory Total and bag co...