Hardware Installation 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for FRM220-CH08

Page 1: ...FRM220 CH08 Hardware Installation...

Page 2: ......

Page 3: ...x 886 2 27991355 Email sales ctcu com URL https www ctcu com FRM220 CH08 Hardware Installation Manual Fiber In band Managed Media Platform Rack 8 Slot 1U Version 1 0 February 7 2012 official release V...

Page 4: ...injury or death that may be associated with such unintended or unauthorized use even if such claim alleges that CTC Union Technologies was negligent regarding the design or manufacture of said product...

Page 5: ...3 Mechanical Assembly 10 2 3 1 Rack mounting 10 2 3 2 Power Fan Modules Removal Replacement 11 2 3 3 Line Card Conversion Stand alone Rack 11 2 4 Electrical Installation 12 2 5 Alarm Installation 12...

Page 6: ...Table of Contents ii...

Page 7: ...dular Media Chassis provides an economic solution for high density Fiber Converter installations in enterprises or central offices All critical components Power fans management module and interface ca...

Page 8: ...1 ON relay 1 is closed ALM 2 Red When On NMC has set Alarm 2 ON relay 2 is closed Figure 1 2 Relays and LEDs 1 4 Chassis Rear Description The rear panel holds the hot swappable power fan modules The...

Page 9: ...CC part 15 subpart B class A Reliability MTTB 65 000 hours 25 C Physical Specifications Dimensions 438mm Width x 302mm Depth x 44mm Height US 17 1 4 wide x 11 7 8 deep x 1 3 4 high Weight 2 6Kg US 5 7...

Page 10: ...t on 2 2 Site Preparation Install the FRM220 CH08 within reach of an easily accessible grounded AC outlet or three wire 48VDC Power return Earth Ground central office power The AC outlet should be cap...

Page 11: ...the 2 7G and 10G the chassis will require two power fan modules or overheating could result Figure 2 2 Power Modules for CH08 2 3 3 Line Card Conversion Stand alone Rack The FRM220 Media Converter Li...

Page 12: ...the power cable in AC installations or via the frame ground connection for DC installations Figure 2 4 IEC AC terminal block DC power connector pin assignment 2 5 Alarm Installation The alarm relay p...

Page 13: ...ings slot number 1 may then be used for a non managed media converter line card 2 7 Line Card Installation The Line Cards for the FRM220 Series are Fiber Media Converter Cards which slide into CH08 ch...

Page 14: ...inal Equipment of PC s COM port The FRM220 includes the 1 1 DB9F to DB9M serial cable for connection to PC s COM port or laptop s USB to RS 232 adapter Any VT100 terminal emulation program for Windows...

Page 15: ...upgrade line cards in the FRM220 Setup the default gateway subnet mask and IP address as instructed by your network administrator After any TCP IP setting change the NMC must be rebooted So ESC back...

Page 16: ...ement IP address The following is an example of a Telnet screen It is the same as a local serial console screen only it can be accessed remotely 3 5 Web Based Manager The FRM220 NMC supports web based...

Page 17: ...d by CTC Union It is a client server architecture using a Windows based server with Microsoft MS SQL Server for a database and Java based server and client The client software can be run on the server...

Page 18: ...Chapter 3 Management Quick Start 18...