background image

COOKER HOOD 

USER HANDBOOK FOR

INSTALLATION AND OPERATION

MODEL CRC60

Summary of Contents for CRC60

Page 1: ...COOKER HOOD USER HANDBOOK FOR INSTALLATION AND OPERATION MODEL CRC60 ...

Page 2: ...e pole isolating switch placed in a readily accessible position adjacent to the unit Electrical Connection Before connecting to the mains supply ensure that the mains voltage corresponds to the voltage on the rating plate inside the Cooker Hood WARNING THIS APPLIANCE MUST NOT BE EARTHED It is fitted with a 2 core mains supply cable and must be permanently connected to the electricity supply via a ...

Page 3: ...k Cover Appliance manufactured in EU Retention of the Instruction Book This Instruction Book must be kept handy for reference as it contains important details on the safe and proper use of the appliance If you sell or pass the appliance to someone else or move house and leave it behind make sure this Book is also provided so the new owner can become familiar with the appliance and safety warnings ...

Page 4: ...ture pack are retained with the hood Dimensions Height adjustable from 685mm up to 850mm Width 600mm Depth 515mm Filter Grilles All measurements are in millimetres Chimney Section Recirculation Grilles Hob Lights Controls Hob Lights On Off Fan Speed Performance Table No of Speeds 3 Pressure pa 290 Capacity m3 h MIN 190 MAX 400 Noise Level dBA MIN 48 MAX 60 ...

Page 5: ...avity of a cavity wall or into a cupboard above the cooker hood If the room contains a flued fuel burning appliance such as a gas or oil fired central heating boiler which is not of the Balanced Flue type you should make sure that there is adequate air inlet into the room at all times so that fumes from the boiler are not drawn back into the room by the Cooker Hood NOTE All installations must comp...

Page 6: ...itions for the fixing screws 3 Drill the two holes for the wall bracket insert the wall plugs and fit the bracket using the screws provided FIXING THE CANOPY HOOD 1 Remove the metal filters Fig 1 4 2 Hang the hood canopy on the hooks Fig 1 3 Adjust the position of the hood using the two screws at the bottom of the hooks Fig 1 5 3 Whilst the hood is positioned mark the two holes Fig 1 6 4 Remove th...

Page 7: ...st not be fitted into the chimney stack until the chimney stack has been installed onto the wall above the canopy EXTRACTION Ducting Fitting The chimney hood can be ducted to the out side using either rigid or flexible ducting of 100mm 120mm or 150mm The choice of ducting is left to the discretion of the installer however the best performance will be obtained by using 150mm of rigid ducting Where ...

Page 8: ...mney are seated into the two recesses on either side of the canopy Fig 5 ATTENTION Should the lower chimney section subsequently be removed the two securing lugs in the top canopy must be released Once the chimney stack has been installed fit the two venting grilles into the apertures located on either side of the lower chimney stack The grilles are marked with two arrows and should be fitted with...

Page 9: ... which point the hood will resume normal functions NEVER do flambé cooking beneath this cooker hood NEVER leave frying pans or deep fat fryers unattended during use overheated fat oil may catch fire Make sure that the Cooker Hood is wired in and the power supply is switched on The Cooker Hood functions are controlled by two slide switches located front centre on the underside of the hood To obtain...

Page 10: ... these instructions TO REMOVE THE GREASE FILTERS Release the catches on the filter Fig 6 then the filter can be removed THE CARBON FILTER 2 pieces Recirculation Model only The carbon filter absorbs odours arising from the cooking In use the filter will slowly become saturated and gradually less effective The filter will normally require changing every four months depending on the amount and type o...

Page 11: ...area of the Cooker Hood not noticeable in normal use NOTE DO NOT use scouring pads or abrasive cleaners as they may scratch the surface How to replace the light Should the light fail to work switch Off the mains supply to the Hood First remove the grease filters Remove the lamp cover and first check the bulb is screwed securely into the lamp holder then switch On at the mains supply If the light s...

Page 12: ... top of the Hood extraction only See page 7 Check if the grease filter needs cleaning See page 10 The light is not working Check the bulb is screwed in securely Replace the light bulb See page11 The Cooker Hood switches off intermittently Check the mounting height above the hob is correct See page 5 The heat from the hob may cause the fan motor to overheat cut out If after following these instruct...

Page 13: ...13 ...

Page 14: ...14 ...

Page 15: ......

Page 16: ...appliance Clear and concise details of the query or fault Place and Date of purchase Please keep the receipt as evidence will be required when the engineer calls Extended Warranty To join UK 08709 088 088 Republic of Ireland 1850 502 200 Genuine Parts Accessories Mail Order Hotline UK 08709 077 077 Republic of Ireland 01 842 6836 For further product information 08701 54 64 74 All Creda Services ar...