background image

PG-F

LEX

 

P

LUS

C

ENTRAL

 O

FFICE

 T

ERMINAL

 S

HELF

P

AIR

G

AIN

 T

ECHNOLOGIES

, I

NC

.

E

NGINEERING

 S

ERVICES

 T

ECHNICAL

 P

RACTICE

S

ECTION

 950-818-100-01

Model

List Number

Part Number

PCS-818

1

150-2618-01

Summary of Contents for 150-2618-01

Page 1: ...PG FLEX PLUS CENTRAL OFFICE TERMINAL SHELF PAIRGAIN TECHNOLOGIES INC ENGINEERING SERVICES TECHNICAL PRACTICE SECTION 950 818 100 01 Model List Number Part Number PCS 818 1 150 2618 01...

Page 2: ...ies Inc and shall not be modified used copied reproduced or disclosed in whole or in part without the written consent of PairGain Information furnished by PairGain Technologies is believed to be accur...

Page 3: ...pment if necessary Check the packing list to ensure complete and accurate shipment of each listed item If the shipment is short or irregular contact PairGain as described in the Limited Warranty on pa...

Page 4: ...acts 4 LAN Interface 6 E1 Connections 7 Specifications 7 Installation Procedures_________________________________________________________________ 8 Required Tools and Test Equipment 8 Power 8 Mounting...

Page 5: ...iations _______________________________________________________________________ 20 Product Support _____________________________________________________________________ 21 Technical Support 21 Limited...

Page 6: ...Table of Contents 950 818 100 01 Revision 01 vi November 30 1999 PCS 818 List 1...

Page 7: ...located on the backplane at the rear of the COT shelf The PCS 818 COT shelf accommodates the following PG Plus units see Figure 1 16 COLUs One Multiplexer Unit PMX One PAU or one PG Plus Management Un...

Page 8: ...t each COLU position The COT shelf provides the signal connectivity and 48 Vdc power distribution in the COT shelf Figure 2 shows the backplane signal interconnection Figure 2 Backplane Signal Configu...

Page 9: ...h unit installed in the COT shelf through the PG FlexPlus Console menus Communication Requests The COT shelf provides a path for communication requests from each of the cards to the PAU PMU slot These...

Page 10: ...up to six pairs are supported by existing COLU s The additional two pairs are for future COLU configurations See Tables 5 through 8 for P1 P2 P3 and P4 connector pinouts Alarm Cutoff The COT shelf bac...

Page 11: ...950 818 100 01 Revision 01 Overview PCS 818 List 1 November 30 1999 5 Figure 4 Alarm Relay Contacts from PAU to Wire Wrap Field...

Page 12: ...9 RS 232 Connector Figure 5 and Table 2 lists the pinouts 10Base 2 Connector see Figure 6 10Base T interface Connector see Figure 6 Figure 5 DB 9 Front View Female Connector Pins Table 2 Pinouts for D...

Page 13: ...ht hand side of the COT shelf backplane The COT shelf backplane also provides wire wrap pins for an external reference clock SPECIFICATIONS Dimensions Height 222 mm 8 7 in Width 533 mm ETSI 21in 482 m...

Page 14: ...DSL reach The table provides the average current drawn from a fully populated shelf under the max condition MOUNTING The PCS 818 can accommodate the EIA 19 inch frames and ETS 300 119 3 frames The mo...

Page 15: ...actices CONNECTIONS The following sections describe the various ground and power connections for the PCS 818 Ground Connections Two Frame Ground termination points are provided on the COT shelf The pr...

Page 16: ...ndant powering or single source powering depending upon requirements The following sections describe the two powering options available on this device The preferred powering method is redundant COT sh...

Page 17: ...Each circuit card in the COT shelf receives power from two 48 Vdc sources If one 48 Vdc source is lost the other 48 Vdc source provides power to the COT shelf circuit cards Each 48 Vdc source is fused...

Page 18: ...e frame ground connection is in place 2 Connect a wire to the 48A terminal at TB1 Figure 8 Connect the opposite end of this wire to the 48 Vdc CO battery supply at the fuse panel 3 Connect a wire to t...

Page 19: ...Clock Connections To terminate the clock leads from the Telco Timing Source Generator to the COT shelf backplane do the following 1 Connect tip of the synchronization reference to EXTCLK_T 2 Connect...

Page 20: ...Installation Procedures 950 818 100 01 Revision 01 14 November 30 1999 PCS 818 List 1 Figure 9 shows the rear view of the COT shelf backplane Figure 9 External Clock Connections...

Page 21: ...helf backplane 2 Install the fuses in the CO fuse panel for the circuits providing 48 Vdc power to the COT shelf Observe that the fuses will not blow when installed 3 Verify that there is between 42 V...

Page 22: ...P1 3 POTS4 POTS4 ISDN P1 36 P1 4 POTS5 P1 37 P1 5 POTS6 P1 38 P1 6 P1 39 P1 7 P1 40 P1 8 LU2 POTS1 POTS1 POTS1 P1 41 P1 9 POTS2 POTS2 POTS2 P1 42 P1 10 POTS3 POTS3 POTS3 P1 43 P1 11 POTS4 POTS4 ISDN...

Page 23: ...6 P2 39 P2 7 P2 40 P2 8 LU6 POTS1 POTS1 POTS1 P2 41 P2 9 POTS2 POTS2 POTS2 P2 42 P2 10 POTS3 POTS3 POTS3 P2 43 P2 11 POTS4 POTS4 ISDN P2 44 P2 12 POTS5 P2 45 P2 13 POTS5 P2 46 P2 14 P2 47 P2 15 P2 48...

Page 24: ...P3 39 P3 7 P3 40 P3 8 LU10 POTS1 POTS1 POTS1 P3 41 P3 9 POTS2 POTS2 POTS2 P3 42 P3 10 POTS3 POTS3 POTS3 P3 43 P3 11 POTS4 POTS4 ISDN P3 44 P3 12 POTS5 P3 45 P3 13 POTS5 P3 46 P3 14 P3 47 P3 15 P3 48 P...

Page 25: ...P4 39 P4 7 P4 40 P4 8 LU14 POTS1 POTS1 POTS1 P4 41 P4 9 POTS2 POTS2 POTS2 P4 42 P4 10 POTS3 POTS3 POTS3 P4 43 P4 11 POTS4 POTS4 ISDN P4 44 P4 12 POTS5 P4 45 P4 13 POTS5 P4 46 P4 14 P4 47 P4 15 P4 48...

Page 26: ...igh bit rate Digital Subscriber Line ICOLU Integrated Central Office Line Unit LAN Local Area Network LED Light emitting Diode LS GS Loop Start Ground Start MLT Mechanized Loop Test NC Normally Closed...

Page 27: ...the 30 day warranty period is at PairGain s option either a return of the price paid or b repair or replacement of the software PairGain also warrants that for a period of 30 days from the date of pur...

Page 28: ...been provided Equipment returned for repair or replacement is subject to a 250 per unit no trouble found NTF charge in the event that diagnostic evaluation reveals no evidence of functional failure or...

Page 29: ...ccordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment doe...

Page 30: ......

Page 31: ...Corporate Office 14402 Franklin Avenue Tustin CA 92780 Tel 714 832 9922 Fax 714 832 9924 For Technical Assistance 800 638 0031...

Reviews: