manualshive.com logo in svg
background image

SAFEPATH

®

4 Facility Communications System & Expansion Options

SP40S Facility Communications System  

 

 

 

 

  

2-4 

Expansion Options

SAFEPATH

®

4

 2-Zone Class A or 4-Zone Class B Speaker Audio Splitter   

   5

SAFEPATH

®

4

 Audio Boosters 

 

 

 

 

 

 

 

 6-7

System Diagram  

 

 

 

 

 

 

 

 

 

 8-9

SAFEPATH

®

4

 Addressable Paging Splitter and Telephone Zone Controller  

  10

SAFEPATH

®

4

 Supervised Volume Control and Remote Microphone  

 

  11

Remote Microphone Expansion Module   

 

   

 

 

 

  12

 

Description

Page

SP40S

SPRM

SP4Z-A/B

SP-SVC

SP4-TZC

151-92-E

S5361

6911-0785:157

SPB-80/4
SPB-160

SPB-320

SP4-APS

Содержание SAFEPATH SP4Z-A-B

Страница 1: ... B Speaker Audio Splitter 5 SAFEPATH 4 Audio Boosters 6 7 System Diagram 8 9 SAFEPATH 4 Addressable Paging Splitter and Telephone Zone Controller 10 SAFEPATH 4 Supervised Volume Control and Remote Microphone 11 Remote Microphone Expansion Module 12 Description Page SP40S SPRM SP4Z A B SP SVC SP4 TZC 151 92 E S5361 6911 0785 157 SPB 80 4 SPB 160 SPB 320 SP4 APS ...

Страница 2: ... pagers for private alerting of emergency trouble conditions System Activation Contact closure message activation Approvals Compliance Approvals UL Standard 864 9th edition UL Standard 1711 California State Fire Marshal CSFM New York City MEA FCC Part 15 OSHA 1910 165 and ADA Compliant 3 Year Warranty Made in the USA Background Music Capable of broadcasting from a supplied BGM source Unique superv...

Страница 3: ...or Remote Microphone connection Installation Maintenance Multiple trouble LED indicators for quick system diagnostics Fully supervised circuitry always in effect even during BGM and general paging via patent pending technology Removable quick connect disconnect terminals for ease of wiring accepts 12 to 22 AWG Power limited circuitry with Class B or Class A wiring Class A only with use of Audio Sp...

Страница 4: ...tention please A fire emergency has been reported in the building While this is being verified please leave the building by the nearest exit Do not use the elevators 2 Fire do not use elevators Female Three 3 rounds of code 3 horn followed by May I have your attention please A fire emergency has been reported in the building While this is being verified please leave the building by the nearest exit Do...

Страница 5: ...ither 25V or 70 7V RMS Mounts inside the enclosure of the SP40S SP40 2 or Audio Boosters Power and Trouble LED s Individual zone short and open LED indication Capable of detecting wiring faults Removable wiring terminals for quick connect disconnect accepting 12 22 AWG All output circuitry is Power Limited Space provided to allow for naming of the zones Powered by 24VDC supplied by the either the ...

Страница 6: ... achieved Additional strobe power can be obtained via a combination of SPB 80 4 or Wheelock Power Supplies Chargers Power Supply Batteries Fully supervised patent pending circuitry always in effect even during BGM Power limited circuitry Class D amplifiers Internal battery charger and power supply Required batteries fit inside the enclosure sold separately SPB 320 requires four 12 VDC 12 AH batterie...

Страница 7: ...150 160 Watt Supervised Audio Power Booster Two 80 watt circuits 220 VAC input black enclosure SPB 80 4 8988 80 Watt Supervised Audio Power Booster with 4 Amps of Supervised and Synchronized Strobe Power Two 2 Amp circuits red enclosure SPB 80 4 B 9931 80 Watt Supervised Audio Power Booster with 4 Amps of Supervised and Synchronized Strobe Power Two 2 Amp circuits black enclosure SPB 80 4E 6147 80...

Страница 8: ...elock Strobe Power Supplies SP40S Supervised Multi Function Communication System SPB 80 4 80 Watt Audio Booster 4 Amps of Strobe Power SPB 160 160 Watt Audio Booster SPB 320 320 Watt Audio Booster SPRM Remote Microphone SP4 RMX Remote Microphone Expansion Module SP4 TZC Telephone Zone Controller SP4 APS Addressable Paging Splitter SP4Z A B Speaker Splitter SP4 SVC Supervised Volume Control Strobe ...

Страница 9: ... SPB 160 SP4Z A B SP4 APS SPB 320 SP4 APS SP4Z A B SPB 160 SP4 APS SP4 APS Wheelock Strobe Power Supply Wheelock Strobe Power Supply SP4 APS SP4 APS SPB 320 SP4 APS SP4 APS SP4 APS SP4Z A B SPB 160 SP4 APS SP4 APS V V V ...

Страница 10: ...ing Splitter SP4 TZC Telephone Zone Controller Class B 4 zones per splitter Up to 68 individual zones 17 splitters 17 fixed zones groups of 4 9 logical zones Class A 2 zones per splitter Up to 34 individual zones 17 splitters 17 fixed zones groups of 2 9 logical zones SP4 TZC Telephone Zone Controller Connects to the SP40S or SP40 2 Auto programmable Custom user programmable for logical zones All ca...

Страница 11: ...rent Standby 26mA Alarm 38mA Audio output level 1 05V RMS 6 wire connection to the SP40S SP40 2 or SP4 RMX Mounting plate is red and measures 8 3 4 x 5 fits into a 4 gang back box All output circuitry is Power Limited SAFEPATH 4 Remote Microphone 11 Applications Features Model Order Code Description SP SVC 9926 Supervised Volume Control for use with the SAFEPATH 4 system Ordering Information SAFEPA...

Страница 12: ...en the SP4 RMX is connected to the SP40S or SP40 2 the entire system benefits from the additional microphone capability Can be connected to Audio Boosters for general non alarm paging with use of SPRM GP UL Standard 864 listed OSHA 1910 165 ADA and UFC compliant Multiple on board diagnostics with 3 status conditions standby alarm and trouble Operates on 24 VDC supplied by the SP40S SP40 2 SPB 80 4 ...

Страница 13: ...its SPB 160 8989 160 Watt Supervised Audio Power Booster Two 80 watt circuits red enclosure SPB 160 B 9930 160 Watt Supervised Audio Power Booster Two 80 watt circuits black enclosure SPB 80 4 8988 80 Watt Supervised Audio Power Booster with 4 Amps of Supervised and Synchronized Strobe Power Two 2 Amp circuits red enclosure SPB 80 4 B 9931 80 Watt Supervised Audio Power Booster with 4 Amps of Supe...

Страница 14: ...shall be made in the USA Approvals for the system shall include UL Standard 864 9th edition UL Standard 1711 FCC part 15 California State Fire Marshal CSFM and New York City MEA The system shall be OSHA 1910 165 and ADA compliant 3 Year Warranty SAFEPATH 4 Audio Boosters The Wheelock SPB 320 SPB 160 and SPB 80 4 Audio Boosters shall be NFPA compliant supervised audio and supervised 24VDC synchroni...

Страница 15: ...odules and shall be capable of addressing all zones at once All Call a maximum of 68 separate zones 17 fixed zone groups and 9 programmed logical zone groups This shall be accomplished using two digit DTMF tones from a page port an unused CO port or a stand alone telephone with a loop start circuit Also the SP4 TZC shall be able to select zones for background music The SP4 TZC has the following inp...

Страница 16: ...o the SP40S or SP40 2 and shall have the capability of providing the SP40S or SP40 2 with up to six system wide All Call Remote Microphone SPRM modules The SP4 RMX can be programmed to provide either priority override for each SPRM module input or First In First Out First In First Out allows the active SPRM to complete its communication before another SPRM can be used All output circuitry shall be...

Отзывы: