background image

NOVA-TS2 User Guide

Version 1.0, August 2021

Summary of Contents for NOVA-TS2

Page 1: ...NOVA TS2 User Guide Version 1 0 August 2021...

Page 2: ...tion and management We recommend you familiarize yourself with this manual in order to make use of the product correctly and effectively The figures and screenshots in this guide are given for illustr...

Page 3: ...injury to personnel CAUTION Indicates a potentially hazardous situation which if not avoided could result in equipment damage data loss performance degradation or unexpected results IMPORTANT Emphasiz...

Page 4: ...attempt to dissemble repair or modify the device yourself Opening or removing covers may expose you to electrical shock or other risks and may void your warranty If the product does not work correctly...

Page 5: ...n of the countries intended for sale Use only the power adapter which is either provided or approved by CMITECH for the product to operate properly and safely DO NOT connect multiple devices to one po...

Page 6: ...2 1 Mounting Device Wall Mount 11 2 2 2 Mounting Device Gang Box Mount 13 2 2 3 Connecting Cables 14 3 Using NOVA TS2 19 3 1 Enrollment 19 3 2 Authentication 20 4 Product Specifications 22 4 1 Mechan...

Page 7: ...2 B 2 Copyright Notice 33 Appendix C Regulatory Information 34 C 1 Certification and Safety Approvals FCC Compliance Statement 34 Appendix D Contact Information 35 NOVA TS2 User Guide 1 0 August 2021...

Page 8: ...permission information can be displayed Supports multiple languages in GUI English Korean Simplified Chinese Traditional Chinese Japanese Arabic Spanish Italian Turkish French Large on board embedded...

Page 9: ...s depending on the application such as a thermal bypass mode without authentication or a mask wearer only mode 1 2 Components Before you begin make sure that all the following items are included with...

Page 10: ...instructions and information needed for product use and installation Diode 1 Prevents currents in unintended directions See Relay Connection for an example of its use Cables Power cable 1 Relay cable...

Page 11: ...s If it is required to use the device in outdoor or extreme environments contact local sales or service cmi tech com for more information Avoid the location that is exposed to backlight direct sunligh...

Page 12: ...gauge 22 AWG or smaller in number Use CAT5 or later for ethernet cable Table 2 Power requirements depending on cable length and wire gauge Input voltage V Wire gauge AWG Power cable length m Note Rec...

Page 13: ...3 Required tools Purpose Name Figure Note General Screw driver Cross head Tape ruler For measuring the installation height Cutting plier Concrete wall mount Electric drill With a drill bit and anchor...

Page 14: ...at attaches NovaFace to the mounting plate and disassemble the plate Keep the screw because it will be used to attach them again 2 Put the mounting plate at the predetermined position and attach the p...

Page 15: ...the screws 3 Connect the power cable and peripherals cables if necessary to the connectors in the rear panel See Connecting Cables for more information 4 Remove one or more plastic tabs to allow the...

Page 16: ...and attach it to the box with the screws M4 x 8 Gang box mounting points Make sure that the outgoing cables from the gang box go through the rectangular opening in the plate 3 Connect the power cable...

Page 17: ...ower Connection Power supply DC Network Connection RJ 45 connector for 10 100 1000Base T Ethernet communication minimum CAT5 cable NOVA TS2 User Guide 1 0 August 2021 Page 14 of 35 www cmi tech com c...

Page 18: ...the NovaFace and the door lock Install the diode at both ends of the circuit as shown in the figure below close to the door lock to protect the relay contact from the reverse current that occurs when...

Page 19: ...Fail Secure Configuration Relay Connection Automatic Door NOVA TS2 User Guide 1 0 August 2021 Page 16 of 35 www cmi tech com c 2021 all rights reserved...

Page 20: ...rm Light Internal relay interface with nominal switching capacity of 1 A 30 VDC or 0 3 A 120 VAC resistive load GPI Connection www cmi tech com c 2021 all rights reserved Page 17 of 35 NOVA TS2 User G...

Page 21: ...Wiegand IN Connection Wiegand OUT Connection NOVA TS2 User Guide 1 0 August 2021 Page 18 of 35 www cmi tech com c 2021 all rights reserved...

Page 22: ...user For Face let the user stand in front of device and complete the face capture For Card put the card on the device s card reader When the CSN card serial number appears on the screen press OK Optio...

Page 23: ...ject will simple and naturally walk toward the face capture range of 0 4 to 2 0 meter Once the system recognizes the subject the result will be displayed immediately with indication line over the subj...

Page 24: ...und the face when your face is detected 2 Authentication result is displayed on the top of the screen depending on whether your face is recognized successfully www cmi tech com c 2021 all rights reser...

Page 25: ...ns 4 1 Mechanical Specifications 4 1 1 Dimensions unit mm Depth 5 5 71 5 142 105 5 53 22 8 74 43 60 5 4 5 Wall Plate 1 4 20 UNC NOVA TS2 User Guide 1 0 August 2021 Page 22 of 35 www cmi tech com c 202...

Page 26: ...cm 200 cm User s height range 145 cm 210 cm with system installed at 135 cm Enrollment speed About 5 seconds Recognition speed About 1 second total in 1 N mode with 20 000 subjects in local database E...

Page 27: ...on Alarm setting Configurable setting of alarm value above baseline temperature Thermal imaging Process displayed on LCD Certifications CE FCC KC Operating temperature range 15 to 35 deg C Measuring t...

Page 28: ...ormal Close NC Gray GPI 300 mm 15 mm 4 1 Pin Name Color Wire Gauge 1 GPI 0 Red 24 AWG 2 GPI 1 Green 3 GPI 2 Yellow 4 Ground GND Black RS 485 300 mm 15 mm 3 1 Pin Name Color Wire Gauge 1 DATA Red 24 AW...

Page 29: ...10 mm 18 AWG 4 3 Environmental Specifications Item Description Note Temperature Operating 5 C to 35 C 40 F to 95 F Non operating 40 C to 60 C 40 F to 140 F Humidity Operating 8 to 85 relative humidity...

Page 30: ...ng an registered user Search Finds users by ID A 2 Device Name Description Bio Fake face Selects a fake face detect option Not used Level low Level high Use mask Selects whether to use mask detection...

Page 31: ...to sensor Not used GPI Port 1 GPI Port 2 GPI Port 3 Sensor type Selects contact state of the GPI port that sensor uses NC NO Tamper Mode Selects a tamper protection mode Not used Beep mode Secure mode...

Page 32: ...eletes all user data Thermal sensor Use sensor Selects whether to use thermal sensor Temperature unit Selects temperature scale Celsius Fahrenheit Alarm temperature Configures elevated temperature ala...

Page 33: ...n 12 hour and 24 hour clock format 12 Hours 24 Hours Menu timeout Select timeout for auto exit from menu display after leaving it untouched Screensaver Selects whether to use screensaver A 5 Authentic...

Page 34: ...order Selects CSN order on card reading MSB LSB Wiegand Output type Selects Wiegand output type Wiegand Card ID A 6 Log Name Description Log info Total used Shows the used space for logs in percent T...

Page 35: ...rior notice The Product may contain links to external websites that are not provided or maintained by or in any way affiliated with the Company Please note that the Company does not guarantee the accu...

Page 36: ...permission from CMITech Co Ltd All other product names trademarks or registered trademarks are property of their respective owners We reserve the right to make any alterations which may be required du...

Page 37: ...o radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception wh...

Page 38: ...ng si Gyeonggi do 14055 Republic of Korea Tel 82 70 8633 8278 Fax 82 31 624 4490 Contact sales cmi tech com CMITech America Inc 2033 Gateway Place Suite 500 San Jose CA 95110 USA Tel 1 408 573 6930 ww...

Reviews: