background image

Cleveland

Project  ________________________________

Item  __________________________________

Quantity _______________________________  

FCSI Section ____________________________

Approval  _______________________________

Date  __________________________________

1333 East 179 St.,

Cleveland, Ohio, U.S.A. 44110 

Tel: 1-216-481-4900

Fax: 1-216-481-3782

Web Site: www.ClevelandRange.com

Email: [email protected]  

 

COMBI OVEN-STEAMER
Stacking Kits for Electric Table Type Models
(OEB 6.20 on OEB 10.20 or OES 6.20 on OES 10.20)

SECT.

IIB

PAGE

5K

0108

Model #

Description

CSTK-1020

for mounting one 6.20 model on top of one 10.20 model

CSTK-1020CA

for mounting one 6.20 model on top of one 10.20 model (with casters)

8

0

.0

9

"

47.92"

2.52"

1.58"

1.82"

3

0

.1

2

"

5.00

"

3

8

.9

8

"

6.00"

8

1

.0

0

(M

IN

.H

O

O

D

R

E

Q

U

IR

E

M

E

N

T

)

RC

CS

W1

W2

D

RC

CS

W1

W2

D

4.38"

48.32"

46.34"

NOTE: Overall height of unit does not change for units with casters.

UNIT A

UNIT A

UNIT B

UNIT B

U

LEFT SIDE VIEW

FRONT VIEW

UTILITIES

(Utility connection shown below are listed per unit)

Required Clearances:

Rear - 2", Left Side - 4", Right Side - 2 1/2"

• Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located next to

the unit.

• Allow for sufficient clearance on left side for service access (contact the factory

service department for recommendations).

• Installation must comply with all local fire and health codes.

Electrical Requirements:

Do not connect to a G.F.I. outlet.

BOILER

UNIT A

- OEB-6.20

UNIT B

- OEB-10.20

MODELS

208/3/60 240/3/60

440/3/60 480/3/60

208/3/60 240/3/60 440/3/60 480/3/60

Total Connected Load:

16.4 KW

21.6 KW

18.5 KW 22 KW

26.3 KW 34.9 KW

29.4 KW 34.9 KW

Hot Air:

14.7 KW

19.6 KW

16.5 KW 19.6 KW

25.8 KW 34.3 KW

28.8 KW 34.3 KW

Steam Generator:

12.8 KW

17.1 KW

14.3 KW 17.1 KW

20.5 KW 27.3 KW

22.9 KW 27.3 KW

Amps per Phase:

45.5

51.8

24.2

26.4

77.8

88.8

41.4

44.9

BOILERLESS

UNIT A

- OES-6.20

UNIT B

- OES-10.20

MODELS

208/3/60 240/3/60

440/3/60 480/3/60

208/3/60 240/3/60 440/3/60 480/3/60

Total Connected Load:

16.4 KW

21.6 KW

18.5 KW 22 KW

26.3 KW 34.9 KW

29.4 KW 34.9 KW

Hot Air:

14.7 KW

19.6 KW

16.5 KW 19.6 KW

25.8 KW 34.3 KW

28.8 KW 34.3 KW

Amps per Phase:

45.5

51.8

24.2

26.4

77.8

88.8

41.4

44.9

Water Connections:

Cold Water (drinking water quality)

Flow Pressure:

30 - 60 PSI

Water Inlets:

3/4" GHT-F (Female Garden Hose

Connection)

Treated Water for Steam Generator

Untreated Water for Condenser

Drain Connection:

2" Tube

Venting:

Exhaust Hood required

*Connection for Cleaning Solution

*Connection for Rinse Cycle

*

Available as an option

Note:

For additional connection details,

see spec sheet for each individual

combi model to be stacked.

D

RC

CS

W1

W2

Reviews: