background image

Summary of Contents for 318064000

Page 1: ...Part No 318064000 Rev B 4372426 Rev A ...

Page 2: ...port 150 pounds and be solid and level Check location where oven will be installed The oven should be located away from strong draft areas such as windows doors and strong heating vents or fans The oven should be located for convenient use in the kitchen Allow 19 318 minimum clearance in front of oven to completely open oven 3 door A ALL OPENINGS IN THE WALL OR FLOOR WHERE THE OVEN IS TO BE INSTAL...

Page 3: ...ressure The inlet pressure to the regulator should be as follows for operation NATURAL GAS Set pressure 4 inches Maximum pressure 14 inches L P GAS Set pressure 10 inches Maximum pressure 14 inches I Line pressure testing Testing above l 2 psi gauge The oven and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pr...

Page 4: ...ting screws add filler strips to each side of the cabinet opening The oven must be secured to the cabinet through mounting holes in both sides of oven frame 7n Measure cabinet opening height The oven cabinet height is 37 3 E If the cabinet opening height is larger the oven height adjusters located on the sides of the oven can be adjusted If no height adjustment is necessary go to Step 9 8a To adiu...

Page 5: ...en bottom Power Failure Do Not attempt to operate the oven in the event of a power failure If a power failure should occur during cooking operation turn the oven control to the off position Failure to turn the oven control off will result in oven operation upon resumption of power to the unit 18 Check the operation of the oven burner Push in and turn the oven control knob to 300 F The oven burner ...

Page 6: ...Remove broiler drawer Shut off gas regulator supply valve in oven B Pressure regulator Remove cap from pressure regulator Remove gasket and plunger from cap Reverse plunger direction so that large end is away from the regulator and push plunger firmly back into the cap Natural should now appear on the exposed end of plunger Replace gasket and cap DO NOT REMOVE PRESSUREREGULATOR L P gas decreases d...

Page 7: ...le and the screws securmg the oven to the cabinet Pull the oven out of the cabmet opening Disconnect the gas supply lme and unplug the power supply cord Complete cleanmg or maintenance Plug power supply cord into outlet and make gas connection Check for leaks Lift oven back into opening Secure oven to cabinet with screws Replace drawer and air grille Turn on gas and electrical supply to oven If yo...

Reviews: