background image

INSTRUCTION 

m

m

.  A800-7425 J (Page 1 of 16)

1.0 GENERAL INFORMATION

1.1

RECEIVING AND UNPACKING

Handle and unpack the equipment carefully.

Operating Conditions

Immediately upon arrival, check the shipment against the
packing list. Any damage should be reported
immediately to the carrier and to the nearest CMC
representative.

Equipment which will not be installed immediately should
be stored in a clean, dry location. Precautions should be
taken to prevent moisture, dust and dirt from
accumulating in storage and installation areas.

1.2

SPECIFICATIONS

Electrical

AC Supply

- 100/115/230VAC ±10%,

50/60Hz,  Jumper selectable

Input Power

- 15 VA

Transducer
Excitation

- 5.6 VDC

Tension
Output Signal

- 0-10 VDC, 5 mA

Conditioned

- 0-10 VDC, 5 mA or adjustable

Tension Output

0-2 VDC, approximately 2K

Signal

Ohm output impedance

Calibration

- Full scale range of 8:1

TLD Output

- 1 N.O. & 1 N.C. 5 Amp,

Contactor

250 VAC resistive (each limit)

(Optional)

Isolation

- 0-10 VDC, 5 mA or 4 to

Amplifier

20 mADC, 1500 VRMS

(Optional)

(2000V peak) isolated

Ambient
Temperature

- 0-40

E

C  (32-104

E

F)

Relative
Humidity

- 5% to 95% (w/o condensation)

Altitude

- to 6600 Ft. (2000 meters)

Weight

Enclosed Indicators - 12 Lbs.

Open Panel
Indicators

- 3 Lbs.

1.3

DESCRIPTION

The indicators are assembled from modules as shown in
Figure 1 on page 2. The modular approach improves
versatility by increasing the combinations of features
available.

1.3.1 Circuit Boards - There are two circuit boards
available.

    - Standard Circuit Board
    - TRL Circuit Board

The Standard circuit board amplifies the signals from the
transducer(s) and provides a tension output signal which
represents  the total tension measured by the
transducers.

The TRL circuit board independently amplifies the
signals from each of two transducers, the left transducer
and the right transducer of the sensing roll. There are
three tension output signals from this circuit board, one
for the left transducer, one for the right transducer, and
one for the total of the left and the right.

Summary of Contents for Cleveland-Kidder TMI

Page 1: ...VAC resistive each limit Optional Isolation 0 10 VDC 5 mA or 4 to Amplifier 20 mADC 1500 VRMS Optional 2000V peak isolated Ambient Temperature 0 40EC 32 104EF Relative Humidity 5 to 95 w o condensatio...

Page 2: ...2 of 18 A800 7425 J Figure 1 1 0 GENERAL INFORMATION...

Page 3: ...provides an isolated 0 10 VDC or a 40 20mADC output 1 3 4 Digital AnalogMeter Blank Plate Option A 3 inch digit panel meter or a 5 inch analog meter are available The blank meter plate can be install...

Page 4: ...stment for the digital between 22TB on the isolation amplifier and 3TB tension meter display on the indicator main circuit board It supplies power to operate the isolation amplifier 10 Isolation Ampli...

Page 5: ...the signals in the indicator The Tensi Master indicators can also be used for cantilever wire and single transducer applications 1 0 GENERAL INFORMATION 2 0 INSTALLATION AC VOLTS JUMPER 100 2TB 23 TO...

Page 6: ...n Insert the line cord into the rectangular hole in the bottom of the enclosure Refer to Figure 4 Make the following connections to terminal block 1TB Brown wire to L1 Blue wire to L2 Green wire to G...

Page 7: ...k through this conduit See Figure 5 3 0 ADJUSTMENTS Check that the indicator has been wired correctly per the installation wiring diagram and that the jumper at 2TB is set for the proper line voltage...

Page 8: ...will cause inaccurate calibration B Apply a known tension load using weights or a spring scale If possible the applied load should be approximately the same as the anticipated operating tension If fo...

Page 9: ...rises above the tension limit detector level set point a set of normally open and normally closed relay contacts on the TLD card will switch states 3 5 ISOLATION AMPLIFIER OPTION Mount the isolation a...

Page 10: ...the maximum working force of the transducers in most cases 4 2 LOW OUTPUT SIGNAL The transducer may have too large a maximum working force for the application Replace with a lower maximum working forc...

Page 11: ...ransducer instruction manual 5 0 REPLACEMENT PARTS Description Use P N Lamp Power ON OFF X01 21443 Switch PB Power ON OFF X16 11705 Lens Red Power ON OFF X01 21442 Lamp 28V TLD X01 11702 Switch PB TLD...

Page 12: ...12 of 18 A800 7425 J 7 0 OUTLINE DIMENSIONS...

Page 13: ...13 of 18 A800 7425 J 7 0 OUTLINE DIMENSIONS...

Page 14: ...ALS 1 2 NORMALLY CLOSED AND 3 4 NORMALLY OPEN WHEN TENSION IS WITHIN THE NORMAL OPERATING LIMITS EACH CONTACT IS RATED AT 5 AMP 115 VAC RESISTIVE 1 2 3 4 5 6 7 8 9 10 11 T L D CARD T L D A B 2 4 3 1 O...

Page 15: ...15 of 18 A800 7425 J INSTRUCTION m m A800 7425 J Page 1 of 16 8 0 INSTALLATION WIRING DIAGRAM...

Page 16: ...16 of 18 A800 7425 J 8 0 INSTALLATION WIRING DIAGRAM...

Page 17: ...COMPANY WITHIN THE APPLICABLE WARRANTY PERIOD OR B DUE TO MISAPPLICATION M O D I F I C A T I O N DISASSEMBLY ABUSE M I S U S E I M P R O P E R I N S T A L L A T I O N UNAUTHORIZED REPAIR IMPROPER MAI...

Page 18: ...HERE ANY MATERIAL OR WORKMANSHIP DEFECTS WHICH BECOME APPARENT WITHIN ONE YEAR FROM THE DATE ON WHICH THE GOODS WERE SHIPPED THE COMPANY SHALL NOT BE LIABLE FOR SPECIAL INCIDENTAL OR CONSEQUENTIAL DAM...

Reviews: