background image

READ AND FOLLOW ALL INSTRUCTIONS IN THIS OWNER

S

MANUAL AND ON EQUIPMENT.

This equipment must be installed and serviced by a qualified technician or professional,
in accordance with the National Electrical Code and all applicable local codes and
Ordinances. Improper installation can create electrical hazards which could result in
property damage, serious injury or death. Improper installation will void the warranty.

Notice to Installer

This manual contains important information about the installation, operation and safe
use of this product. Once the product has been installed this manual must be given to
the owner/ operator of this equipment.

Pool Pumps

Item #s  CSPPD704

CSPPD705

Summary of Contents for CSPPD704

Page 1: ...s and Ordinances Improper installation can create electrical hazards which could result in property damage serious injury or death Improper installation will void the warranty Notice to Installer This...

Page 2: ...at the circuit breaker before servicing the pump Failure to do so could result in death or serious injury to service person pool users or others due to electric shock Pumps improperly sized or instal...

Page 3: ...cured GENERAL SAFETY RULES 1 The products mentioned in this manual are specially designed for the pre filtering and re circulation of water in swimming pools and spas 2 They are designed to work with...

Page 4: ...ruction concerning use of the appliance by a person responsible for their safety 16 The pump must be protected from running dry LOCATION The pump must be located as close as practical to the pool The...

Page 5: ...d on IEC 364 7 702 requirements RESPECT THE MINIMUM GAUGE GIVEN IN THE CHART OF THE TECHNICAL MANUAL Electrical Connection Check that the information on the nameplate corresponds to the power supply E...

Page 6: ...nded in a swimming pool when high speed is needed for maximum filtration at peak periods and whenever turbidity levels are high At other times switch to low speed For backwashing and vacuuming high sp...

Page 7: ...d adaptations and supplementary technical rules may be necessary 4 Before starting the pump verify the calibration of the electrical protection devices of the motor and that the protections against el...

Page 8: ...the case of any excessive high stop immediately and have it repaired CAUTION Owing to the complexity of the cases covered the instructions for installation use and maintenance contained in this manual...

Page 9: ...9b 647272971000 Impeller For CSPPD704 1 9c 647252771000 Impeller For CSPPD705 1 10 65431044080 O Ring 1 11 65028003000 Seal Assembly 1 12 647284803 Pump Housing 1 13 647284804 Motor Mounting Plate 1 1...

Page 10: ...or controls Faulty Pump shaft motor Replace the pump motor assembly Pump shaft is locked Check if the pump can be rotated by hand and remove any blockage Pump will not prime Suction air leak Make sur...

Page 11: ...ncorrect voltage Supply to be corrected by electrician A motor running hot to touch is normal Thermal overload protector will function to turn them off if there is an overload or excessive high temper...

Page 12: ......