PN401

FXTH

161-051300-001

FEBRUARY, 2008

4

and

Installation, Operation

RENEWAL PARTS IDENTIFICATION

Chromalox

®

Chromalox Type FXTH Flexible Tank Heater

Amp / Tube

Catalog Number of Recommended

Minimum

Heater

Heater

No. Tubes

Approx

OCC or WCC Control Centers

Manhole

Length

Width

and

Catalog

Net Wt.

kW

240

480

Size (In.)

B

C

Circuits

Number*

Lbs.

240V

480V

*Suffix letters with FXTH Catalog Number indicate modification from standard as follows:

V= Voltage, W= Wattage, A= change in riser length, R= low temperature alarm contactor, D= temperature indicator and XX = special.

Thermowell

3/4” NPT

Thermowell

Riser

Three Tube

Heater Assembly

Two Tube

Heater Assembly

Single Tube

Heater Assembly

Heater

Terminal

Housing

2-1/2” NPT

6-1/4”

2”

Vent Tube

Notes:

1.  Min. fluid Depth for safe heater operation is 12”.
2.  5/8” - 11 x 1 in. long hex head bolts. 8 required.

Heater Terminal Housing

Gasket (Furnished)

Manhole Adapter (Optional)

Customer Manhole Cover

Lifting Cables

Overtemperature
Sensor

C

9-3/16”

14’

B

8”

12”

Bolts. See
Note 2

6

15

7

14

12’3-3/4”

5-1/4

1

FXTH-11206

79

(OCC or WCC)-15-213

WCC-10-413

8

19

10

14

15’3-3/4”

5-1/4

1

FXTH-11508

97

WCC-25-213

WCC-10-413

10

24

12

14

15’3-3/4”

5-1/4

1

FXTH-11510

97

WCC-25-213

WCC-15-413

12

29

14

14

15’3-3/4”

5-1/4

1

FXTH-11512

97

WCC-30-213

WCC-15-413

10

24

12

14

20’3-3/4”

5-1/4

1

FXTH-12010

127

WCC-25-213

WCC-15-413

12

29

14

14

20’3-3/4”

5-1/4

1

FXTH-12012

127

WCC-30-213

WCC-15-413

15

36

18

14

20’3-3/4”

5-1/4

1

FXTH-12015

127

WCC-40-213

WCC-20-413

18

43

22

14

27’1”

5-1/4

1

FXTH-12718

170

WCC-45-213

WCC-25-413

21

51

25

14

30’1”

5-1/4

1

FXTH-13021

190

WCC-55-213

WCC-30-413

24

58

29

14

32’1”

5-1/4

1

FXTH-13224

205

WCC-60-213

WCC-30-413

27

65

33

14

35’1”

5-1/4

1

FXTH-13527

225

WCC-70-213

WCC-35-413

30

72

36

14

40’1”

5-1/4

1

FXTH-14030

250

WCC-75-213

WCC-40-413

12

15

7

18

12’3-3/4”

10-1/4

2

FXTH-21212

157

WCC-15-223

WCC-10-423

16

19

10

18

15’3-3/4”

10-1/4

2

FXTH-21516

194

WCC-25-223

WCC-10-423

20

24

12

18

15’3-3/4”

10-1/4

2

FXTH-21520

194

WCC-25-223

WCC-15-423

24

29

14

18

15’3-3/4”

10-1/4

2

FXTH-21524

194

WCC-30-223

WCC-15-423

20

24

12

18

20’3-3/4”

10-1/4

2

FXTH-22020

253

WCC-25-223

WCC-15-423

24

29

14

18

20’3-3/4”

10-1/4

2

FXTH-22024

253

WCC-30-223

WCC-15-423

30

36

18

18

20’3-3/4”

10-1/4

2

FXTH-22030

253

WCC-40-223

WCC-20-423

36

43

22

18

27’1”

10-1/4

2

FXTH-22736

340

WCC-45-223

WCC-25-423

42

51

25

18

30’1”

10-1/4

2

FXTH-23042

380

WCC-55-223

WCC-30-423

48

58

29

18

32’1”

10-1/4

2

FXTH-23248

405

WCC-60-223

WCC-30-423

54

65

33

18

35’1”

10-1/4

2

FXTH-23554

440

WCC-70-223

WCC-35-423

60

72

36

18

40’1”

10-1/4

2

FXTH-24060

500

WCC-75-223

WCC-40-423

18

15

7

24

15’3-3/4”

15-1/4

3

FXTH-31218

236

WCC-15-233

WCC-10-433

30

24

12

24

15’3-3/4”

15-1/4

3

FXTH-31530

291

WCC-25-233

WCC-15-433

36

29

14

24

15’3-3/4”

15-1/4

3

FXTH-31536

291

WCC-30-233

WCC-15-433

30

24

12

24

20’3-3/4”

15-1/4

3

FXTH-32030

370

WCC-25-233

WCC-15-433

36

29

14

24

20’3-3/4”

15-1/4

3

FXTH-32036

370

WCC-30-233

WCC-15-433

45

36

18

24

20’3-3/4”

15-1/4

3

FXTH-32045

370

WCC-40-233

(OCC or WCC)-20-433

© 2010 Chromalox, Inc.

Specifications – Type FXTH

Summary of Contents for FXTH PN401

Page 1: ...3 3 4 5 1 4 1 FXTH 12015 127 WCC 40 213 WCC 20 413 18 43 22 14 27 1 5 1 4 1 FXTH 12718 170 WCC 45 213 WCC 25 413 21 51 25 14 30 1 5 1 4 1 FXTH 13021 190 WCC 55 213 WCC 30 413 24 58 29 14 32 1 5 1 4 1...

Page 2: ...during shipping Contact carrier if heater shows signs of damage Do not attempt to install heater if damage is evident Do not attempt to tighten or remove any of the threaded fittings in the flexible...

Page 3: ...on The heater must not be energized unless it is completely submerged 7 Machine manhole cover per Figure B or install optional terminal housing manhole adapter to manhole cover or storage tank per Fig...

Page 4: ...on under side of terminal housing C Bolt terminal housing to manhole cover or manhole cover adapter again using suitable gasket cement If manhole cover is machined per Figure B be sure to install copp...

Page 5: ...N All conduit con nections to terminal housing must be sealed to prevent entry of any water water vapor or condensation into terminal housing Breather tube length may be cut to shorten height or exten...

Page 6: ...o grounding lug in control box and from control box to a suitable ground 4 Connect power cable of proper voltage to input of control box 5 Secure control box door then place circuit breaker in on posi...

Page 7: ...thermocouples for a number of different gauges of wire By using this table it is necessary only to measure the length of the thermocouple knowing the type and gauge to determine its approximate resis...

Page 8: ...ter Flange 121 115692 001 Manhole adapter Housing 065 115693 001 Flange Gasket 132 115515 001 Housing Gasket 132 113661 001 Thermostat 300 115621 001 Thermocouple Probe 309 121168 001 Circuit Breaker...

Page 9: ...pole 072 120812 005 2 Fuses FNQ V2 F1 and F2 128 114696 010 1 Transformer 150VA 315 048507 018 OCC or WCC 30 223 240V 2 3 24 kW 1 Circuit Breaker 240V 80 Amp 3 pole 104 071818 012 2 Contactors 600V 3...

Page 10: ...40 001 OCC or WCC 40 233 240V 3 3 45 kW 1 Circuit Breaker 600V 150 Amp 3 pole 104 071818 046 3 Contactors 600V 60 Amp 3 pole 072 120812 002 9 Fuses FRN 45 F3 thru F11 128 121133 078 1 Transformer 250V...

Page 11: ...11...

Page 12: ...LVD LAVERGNE TN 37086 Phone 615 793 3900 www chromalox com Limited Warranty Please refer to the Chromalox limited warranty applicable to this product at http www chromalox com customer service policie...