background image

800/1000 watt  

pure sine wave

pOwer inverter with GFCi

66835

set up and OperatinG instruCtiOns

distributed exclusively by Harbor Freight tools

®

.

3491 Mission Oaks Blvd., Camarillo, CA 93011

visit our website at: http://www.harborfreight.com

 read this material before using this product. 

Failure to do so can result in serious injury. 

save tHis manual.

Copyright

©

 2009 by Harbor Freight Tools

®

.  All rights reserved.  No portion of this manual 

or any artwork contained herein may be reproduced in any shape or form without the 

express written consent of Harbor Freight Tools.  Diagrams within this manual may not be 

drawn proportionally.  Due to continuing improvements, actual product may differ slightly 

from the product described herein.  Tools required for assembly and service may not be 

included.

For technical questions or replacement parts, please call 1-800-444-3353.

Summary of Contents for 66835

Page 1: ...Save this manual Copyright 2009 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools Diagrams within this manual may not be drawn proportionally Due to continuing improvements actual product may differ slightly from the product described herein Tools r...

Page 2: ...ot avoided could result in minor or moderate injury NOTICE is used to address practices not related to personal injury CAUTION without the safety alert symbol is used to address practices not related to personal injury General Safety Warnings WARNING Read all safety warnings and instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Sav...

Page 3: ...erter or the ap pliance When first using a recharge able device check its temperature for the first 10 minutes If it becomes abnormally hot do not use this de vice with the Inverter This device is designed for use in 14 12 VDC negative ground systems only Allow adequate ventilation Do not 15 cover this unit while it is plugged in This unit generates heat without proper ventilation it may overheat ...

Page 4: ... be supplied by the operator Specifications Continuous Power 800 Watts Peak Power 1000 Watts Input Voltage 12 Volts Nominal DC 10 15VDC possible Output Voltage 120V 60Hz Fuse 40A x 4 Blade Type Indicators Green LED power on Red LED error fault Switch Rocker type ON OFF Output Wave Form Pure Sine Wave Cables not included 4AWG or larger heavy duty input Outlets 2 120V grounded AC with Ground Fault C...

Page 5: ...intended only 6 Inspect before every use do not use 7 if parts are loose or damaged Maintain product labels and name 8 plates These carry important safety information If unreadable or miss ing contact Harbor Freight Tools for a replacement Operating Instructions Read the entire Important Safety Information section at the beginning of this manual including all text under subheadings therein before ...

Page 6: ...ng To power a device or appliance 7 With the device or a appliance switched off plug it into one of the Power Outlets on the Power Inverter Repeat for a second device or b appli ance if needed Turn on the devices and or c appli ances After use unplug the appliance turn 8 off the car engine if it is running and remove the cables from the battery and the Power Inverter Note The total wattage of all ...

Page 7: ...id touching any interior parts of the Inverter except the fuses when replacing the fuses Keep this unit clean and dry Unplug 1 the unit before cleaning Clean only the outside of this unit with a soft dry cloth never clean this unit with water or harsh cleaners Aside from the fuses this device 2 does not contain any user replace able parts If it needs service or if you do not feel qualified to chan...

Page 8: ...t the modified sine wave produced by the inverter Use a sound system that incorporates a higher quality power supply This inverter is made to minimize the interference with TV signals However es 5 pecially with weak TV signals some interference may still be visible To correct this place the inverter as far away as possible from the television antenna and it s cables Next adjust the orientation of ...

Page 9: ... 2 Part Description Qty 11 Bottom 1 12 Fan Cover 1 13 Bottom Fan 1 14 Outlet Side Plate 1 15 Switch 1 16 Outlet 1 17 Flange 1 18 Flange 1 19 Flange 1 20 Flange 1 1 6 11 17 2 7 12 18 3 8 13 19 4 9 14 20 5 10 15 16 Parts List Diagram Record Serial Number Here Note If product has no serial number record month and year of purchase instead Note Some parts are listed and shown for illustration purposes ...

Page 10: ...negligence or accidents repairs or alterations outside our facilities criminal activity improper installation normal wear and tear or to lack of maintenance We shall in no event be liable for death injuries to persons or property or for incidental contingent special or consequential damages arising from the use of our product Some states do not allow the exclusion or limitation of incidental or co...

Reviews: