background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

User Manual 

Summary of Contents for SlimBANK T18 USB

Page 1: ...User Manual ...

Page 2: ...nu Map 9 DMX Linking 10 Configuration DMX 10 D Fi USB Connectivity 10 Configuration D Fi USB 10 DMX Personality and Starting Address 11 DMX Channel Assignments and Values 11 13CH 11 9 CH 12 9 CH cont 13 5 CH 13 3 CH 13 Configuration Standalone 14 Automatic Programs 14 Auto Program Speed 14 Sound Active Mode 14 Sound Sensitivity 14 Preset Color Mode 14 Custom Color Mixing 14 Dimmer Speed 14 Tempera...

Page 3: ...nformation Not following these instructions may make the product not work cause damage to the product or cause harm to the operator Important installation or configuration information The product may not function correctly if this information is not used Useful information Disclaimer Chauvet believes that the information contained in this manual is accurate in all respects However Chauvet assumes ...

Page 4: ...sure that the voltage of the outlet to which you are connecting the product is within the range stated on the decal or rear panel of the product The product is for indoor use only IP20 To prevent risk of fire or shock do not expose the product to rain or moisture Always install the product in a location with adequate ventilation at least 20 in 50 cm from adjacent surfaces Be sure that no ventilati...

Page 5: ...erview WARNING DO NOT plug anything other than a D Fi USB into the USB port Doing so may cause damage to the product DMX In Out Power In Microphone D Fi USB Port Power Out Safety Cable Pass Through Fuse Holder Display Menu Buttons Back Panel View Front View Lenses IR Sensor ...

Page 6: ...Page 6 of 20 SlimBANK T18 USB User Manual Rev 1 Product Dimensions 15 5 in 395 mm 2 1 in 55 mm 10 2 in 260 mm ...

Page 7: ... rheostat or dimmer channel serves only as a 0 to 100 switch Fuse Replacement 1 Wedge the tip of a flat head screwdriver into the slot of the fuse holder 2 Pry the fuse holder out of the housing 3 Remove the blown fuse from the holder and replace with a fuse of the exact same type and rating 4 Insert the fuse holder back in place and reconnect power Disconnect the product from the power outlet bef...

Page 8: ...he Technical Specifications for weight information When mounting the product overhead always use a safety cable Mount the product securely to a rigging point whether an elevated platform or a truss When rigging the product onto a truss use a mounting clamp of appropriate weight capacity When power linking multiple products mount the products close enough for power linking cables to reach The brack...

Page 9: ...r to find a lower value ENTER Press to activate a menu option or a selected value Menu Map Main Level Programming Levels Description 3 CH d001 512 3 channel DMX mode 5 CH d001 512 5 channel DMX mode 9 CH d001 512 9 channel DMX mode 13CH d001 512 13 channel DMX mode C C1 18 Static colors P automatic P1 14 Automatic programs S S 1 100 Program speed for P1 P14 Snd sound active Snd Sound Active progra...

Page 10: ...uvet DJ Simply set the product s DMX Personality and DMX Address set the DIP switch D Fi receiving transmitting channel then plug it into the D Fi USB port WARNING DO NOT plug anything other than a D Fi USB into the USB port Doing so may cause damage to the product Once plugged in the D Fi USB will take over the product Wired DMX manual display control menu buttons and IRC will be unavailable unti...

Page 11: ...X Channel Assignments and Values 13CH Channel Function Value Percent Setting 1 Red 1 000 ó 255 0 100 2 Green 1 000 ó 255 0 100 3 Blue 1 000 ó 255 0 100 4 Red 2 000 ó 255 0 100 5 Green 2 000 ó 255 0 100 6 Blue 2 000 ó 255 0 100 7 Red 3 000 ó 255 0 100 8 Green 3 000 ó 255 0 100 9 Blue 3 000 ó 255 0 100 10 Auto Programs 000 ó 010 No function 011 ó 028 Auto program 1 029 ó 045 Auto program 2 046 ó 062...

Page 12: ... B 100 201 ó 205 Color temperature 1 206 ó 210 Color temperature 2 211 ó 215 Color temperature 3 216 ó 220 Color temperature 4 221 ó 225 Color temperature 5 226 ó 230 Color temperature 6 231 ó 235 Color temperature 7 236 ó 240 Color temperature 8 241 ó 245 Color temperature 9 246 ó 250 Color temperature 10 251 ó 255 Color temperature 11 7 Auto Programs 000 ó 010 No function 011 ó 028 Auto program ...

Page 13: ...er speed set from menu 052ó 101 Dimmer speed mode off 102 ó 152 Dimmer speed mode 1 fast speed 153 ó 203 Dimmer speed mode 2 medium speed 204 ó 255 Dimmer speed mode 3 slow speed 5 CH Channel Function Value Percent Setting 1 Dimmer 000 ó 255 0 100 2 Red 000 ó 255 0 100 3 Green 000 ó 255 0 100 4 Blue 000 ó 255 0 100 5 Strobe 000 ó 010 No function 011 ó 255 Strobe slow to fast 3 CH Channel Function ...

Page 14: ...usic bass and drums Sound Sensitivity To change the sound sensitivity on the SlimBANK T18 USB do the following 1 Press MENU repeatedly until SenS shows on the display 2 Use UP and DOWN to increase or decrease the sound sensitivity u 0 100 3 Press ENTER The product will return to the last selected mode Preset Color Mode To run the SlimBANK T18 USB in preset color mode follow the instructions below ...

Page 15: ...IVITY on the IRC 6 2 Press or to increase or decrease the sound sensitivity Manual Color Control To choose a specific color with the IRC 6 1 Press MANUAL on the IRC 6 2 Press any number between 0 9 to choose your color To manually control the RGB percentage 1 Press MANUAL on the IRC 6 2 Press R red G green or B blue to choose your color 3 Press or to increase or decrease the percentage of each col...

Page 16: ...r Slave operation because the controller may interfere with the signals from the master Do not connect more than 31 slaves to the master Master Slave Mode D Fi USB The D Fi USB allows a single SlimBANK T18 USB product the master to control the actions of one or more SlimBANK T18 USB products the slaves without the need of a DMX controller or DMX cables The master transmitter product will be set to...

Page 17: ...cy To clean the product follow the instructions below 1 Unplug the product from power 2 Wait until the product is at room temperature 3 Use a vacuum or dry compressed air and a soft brush to remove dust collected on the external surface vents 4 Clean all transparent surfaces with a mild soap solution ammonia free glass cleaner or isopropyl alcohol 5 Apply the solution directly to a soft lint free ...

Page 18: ...wer linking current products 8 A 13 products 8 A 24 products Fuse T 1 A 250 V T 1 A 250 V Power I O U S Worldwide UK Europe Power input connector IEC IEC Power output connector Edison IEC Power Cord plug Edison U S Local plug Light Source Type Power Lifespan LED 3 W 50 000 hours Color Quantity Current Tri color RGB 18 1050 mA Photometrics Parameter Value Strobe Rate 0 to 22 Hz Beam Angle 17 Field ...

Page 19: ...chnical Support office and request a Return Merchandise Authorization RMA number before shipping the product Be prepared to provide the model number serial number and a brief description of the cause for the return Send the merchandise prepaid in its original box and with its original packing and accessories Chauvet will not issue call tags Clearly label the package with the RMA number Chauvet wil...

Page 20: ...ing eu World Wide Web www chauvetlighting eu General Information Chauvet Europe Ltd Address Unit 1C Brookhill Road Industrial Estate Pinxton Nottingham UK NG16 6NT Voice 44 0 1773 511115 Fax 44 0 1773 511110 Technical Support Email uktech chauvetlighting com World Wide Web www chauvetlighting co uk MEXICO General Information Chauvet Mexico Address Av Santa Ana 30 Parque Industrial Lerma Lerma Mexi...