Page 3: ...You Need Further Help Health Safety Precautions Specification Chimney Hearth Fire Surround Connection to Flues Soot Doors Unpacking The Stove Pre Lighting Check Commissioning Dimensions Parts Lists Certification 4 4 4 5 5 5 5 6 6 6 7 8 9 9 9 9 10 10 10 11 11 12 13 14 INSTALLATION INSTRUCTIONS Lighting 4 Controlling The Fire Fitting The Stove To Its Stand 10 Ref COVE2SR 06 13 Issue E ...

Page 4: ...NS THESE OPERATING INSTRUCTIONS MUST BE ADHERED TO When using the stove in situations where children aged and or infirm persons are present a fireguard must be used to prevent accidental contact with the stove The fireguard should be manufactured in accordance with BS 8423 2002 Before lighting the stove check with the installer that the work and checks described in the Installation Instructions ha...

Page 5: ... For correct firing we recommend the use of a stove pipe thermometer which may be purchased from your supplier or from ourselves Logs must NOT be loaded above the level of the air holes in the back firebrick RIDDLING When burning wood ash should be allowed to build up and only riddled when the ash begins to cover the slots in the rear fireplate The fire should be riddled with the door shut see Fig...

Page 6: ...ll weaken the glass and cause premature failure Aerosol spray cleaners should not be used near the appliance whilst it is under fire If the fire is going to be out of use for a long period for instance in the summer then to prevent condensation and hence corrosion the air control should be left fully open and the fire door left ajar It is also advisable to sweep the chimney and clean out the fire ...

Page 7: ...sweeping should be consulted TROUBLE SHOOTING Fire Will Not Burn Blackening of Door Glass following points should be noted and with a little care should enable the glass to be kept clean in most situations a The airwash relies on a supply of heated air to keep the glass clean therefore when lighting the stove allow the fire bed to become well established before closing the air control This also ap...

Page 8: ...the above action is taken then the fire brigade should be called immediately After a chimney fire the chimney should be carefully examined forany damage Expert advice should be sought if necessary If you need further help with your Charnwood Cove then your Installer will be able to provide the answers to most questions Your Local Charnwood Premier Dealer has a great deal of experience and will als...

Page 9: ...chimney then a prefabricated block chimney or a twin walled insulated stainless steel flue to BS EN 15287 1 2007 can be used either internally or externally These chimneys must be fitted in accordance with the manufacturers instructions and Building Regulations Anki pumice liners or chimney blocks will give a highly insulated chimney which will work well with all fuels For details ring Anki Chimne...

Page 10: ...al lengths of flue must be kept to a minimum and should not be more than 150mm 6 inches long The sealing face of the flue collar should be coated with fire cement before fixing to the body of the stove using the two screws provided The blanking plate must be removed sealed with fire cement and refitted care being taken to ensure that the fold on the clamping plate is in line with the lugs on the f...

Page 11: ...nsure that it has not become dislodged in PRE LIGHTING CHECK transit The method of location and positioning of the throat plate is shown in Fig 4 On completion of the installation and after allowing a suitable period of time for the fire cement and mortar to dry out the stove should be lit and checked to ensure that smoke and fumes are taken from the appliance up the chimney and emitted safely Als...

Page 12: ...LOW STAND STAND STORE STAND TOP VIEW Optional Vertical Rear Flue Adapter 402 402 153 145 459 88 554 949 894 514 402 350 153 779 949 894 300 124 247 103 27 779 718 662 119 548 12 charnwood DIMENSIONS mm Flue outlet to suit 150mm 6 flue pipe ...

Page 13: ...7 012 AY13 Idler Rod 18 012 AY15 Riddler Rod 19 004 PY17 Ashpan 20 002 AY07B Front Firebar 21 002 AY08 Deepening Bar 22 002 RY15 Door Knob Spindle 23 008 FFN001 M12 Half Nut 24 004 ST008 Tabbed Locking Washer 25 002 AY14 Door Catch 26 010 ST031 Door Catch Spacer 27 008 FFW015 M12 Double Coil Spring Washer 28 008 PY13 Door Riddling Ashpan Tool 29 008 BW39 S Hinge Pin Set 30 002 PY24 Hinge Post 31 0...

Page 14: ...Rear Emission of CO in combustion products Flue gas temperature Space heating thermal output Energy efficiency A Division of A J Wells Sons Limited Registered in England No 03809371 10 Bishops Way Newport Isle of Wight PO30 5WS United Kingdom A J WELLS SONS LTD A J WELLS SONS LTD HS44 CPD 2006 450mm 600mm 0 33 338 C 8 0kW 74 7 Wood Logs ...

Page 15: ......

Page 16: ...r e d i n E n g l a n d N o 0 3 8 0 9 3 71 charnwood BISHOPS WAY NEWPORT ISLE OF WIGHT PO30 5WS UNITED KINGDOM T 4 4 0 19 8 3 5 3 7 7 7 7 F 4 4 0 19 8 3 5 3 7 7 8 8 C O N TA C T U S AT W W W C H A R N W O O D C O M y o u r p re m i e r d e a l e r REV COVE2SR 06 13 ISSUE E ...