background image


 
 
 
 
 
 

 
 
 
 
 
 

 

 
 
 
 
 
 
 

 

 

 
 

 

CBSArcSafe®

 

 

RSA-102  

 

In

s

ta

ll

a

ti

o

n

 a

n

d

 O

p

e

ra

ti

o

n

 

P.O. Box 550 

Argyle, TX 76226 

(940) 382-4411 

www.cbsarcsafe.com 

FP 400 Amp  
Switchmatic 

Summary of Contents for RSA-102

Page 1: ... CBSArcSafe RSA 102 Installation and Operation P O Box 550 Argyle TX 76226 940 382 4411 www cbsarcsafe com FP 400 Amp Switchmatic ...

Page 2: ...er to be serviced does not match please call CBS ArcSafe for more information regarding switching applications for your particular model of switch 1 1 RSA 102 Alignment Locations for Breaker Installation ATTENTION The numbers depicted on the breaker below correspond to where the RSA 102 needs to align on the breaker 1 2 3 4 5 Figure 1 FP 400 Amp Switchmatic ...

Page 3: ...mbered locations in Figure 1 slight adjustments need to be made for proper operation These adjustments will be discussed in the next section of the manual ATTENTION The numbers depicted on the RSA 102 correspond to the breaker alignment locations from Figure 1 1 2 4 3 5 Figure 2 RSA 102 Alignment locations ...

Page 4: ...2 RSA 102 Adjustment Locations To widen the RSA 102 loosen the screws of the following locations and slide the left support outward This adjustment will help the RSA 102 fit more securely between the breaker door and the left hinge as seen in the image below ...

Page 5: ...ove to limit the travel of the handle This will keep the RSA 102 to from damaging the ON OFF Switch They can be adjusted with an Allen wrench then raised or lowered to the proper height The two handle grips can be adjusted to fit a wider handle by unscrewing and moving to the open holes as seen in the image above ...

Page 6: ...the motor control box 3 Power the RSO I on ATTENTION Please ensure that either the batteries on the unit are fully charged or the unit is plugged into AC power 4 If the switch is connected on press and hold the TRIP button until the switch opens to turn the switch off 5 If the switch is disconnected off press and hold the CLOSE button until the switch closes to turn the switch on ...

Page 7: ......

Page 8: ...correctly stationed outside the arc flash boundary and that they comply with all applicable Federal State Local and In house safety regulations and procedures Attention should be given to distance angle and personal protective equipment PPE P O Box 550 Argyle TX 76226 Tel 940 382 4411 Fax 940 382 9435 Website www CBSArcSafe com Email info CBSArcSafe com ...

Reviews: