manualshive.com logo in svg
background image

 
 
 
 
 

PZ3000 Series 

Ingredient Scale 

Owner’s Manual 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

CARDINAL SCALE MFG. CO. 

8528-M372-O1 Rev E 

PO BOX 151 

WEBB CITY, MO 64870

Printed in USA

05/14 

PH (417) 673-4631 

FAX (417) 673-5001

 

 

www.detectoscale.com  

Technical Support: Ph: 866-254-8261 

 [email protected] 

Содержание Detecto PZ3000 Series

Страница 1: ...t Scale Owner s Manual CARDINAL SCALE MFG CO 8528 M372 O1 Rev E PO BOX 151 WEBB CITY MO 64870 Printed in USA 05 14 PH 417 673 4631 FAX 417 673 5001 www detectoscale com Technical Support Ph 866 254 8261 techsupport cardet com ...

Страница 2: ......

Страница 3: ...his manual the Seller assumes no responsibility for errors or omissions Neither is any liability assumed for damages resulting from use of the information contained herein All instructions and diagrams have been checked for accuracy and ease of application however success and safety in working with tools depend to a great extent upon the individual accuracy skill and caution For this reason the Se...

Страница 4: ...ay special attention to all NOTIFICATION symbols IMPORTANT ELECTRICAL WARNING Serial Number_______________________ Date of Purchase ____________________ Purchased Form_____________________ ___________________________________ ___________________________________ RETAIN THIS INFORMATION FOR FUTURE USE ...

Страница 5: ...t Place the screws on the display in the bracket and gently pull forward to secure the display to the bracket 4 Plug the AC power supply into the power jack located on the bottom side of the display refer to Figure 1 and then connect the AC power adapter into the proper electrical outlet 5 If it is desired to use the scale remotely no AC power with the exception of the PZ3060 you must first obtain...

Страница 6: ...ttery is at 50 of capacity 1 segment the battery is at 25 capacity When the battery voltage drops too low for accurate weighing the display will show LoBAt and then shut off You will be unable to turn the display back on until the AC power supply is connected to the display to operate it and recharge the batteries Battery Charging To recharge the NiMH batteries the AC power supply must be connecte...

Страница 7: ... from the battery holder If installing new batteries proceed to step 12 NOTE To insure optimum performance of your PZ3000 when powered by the internal battery replace all 6 batteries with new AA size NiMH batteries 2300mAh minimum DO NOT mix new and used batteries 12 Install the 6 new AA size batteries in the battery holder noting the polarity markings located in the battery holder Refer to Figure...

Страница 8: ...from the scale wall or table stand 2 Turn the indicator so that the display is facing away from you and place it face down on a table or bench 3 Referring to Figure No 2 locate the two screws on the angled edge of the indicator and remove the screws and washers under them NOTE The PZ3015 and PZ3030 use two thumbscrews and the PZ3060 uses two socket head cap screws 4 Referring to Figure No 6 remove...

Страница 9: ...llow approximately 4 to 8 hours to fully recharge the batteries OPTIONAL ZERO DEVICES In addition to the standard display pushbutton and Lite Way hands free methods to zero the weight the PZ3000 Series has an optional Foot Pedal or Mountable Pushbutton available The model numbers for the optional zero devices are PZFS for the foot pedal and PZPB for the mountable pushbutton Optional Zero Device Pl...

Страница 10: ...e key for approximately 2 seconds for the scale to power up If the scale is already on pressing this key quickly will turn the scale off This key is also used to lock the weighing units Refer to the Operation section of this manual for instructions on locking the weighing units This key is used to select the units in which the weight is to be displayed The available units include pounds only ounce...

Страница 11: ...ht display is stable When off it means that the change in successive weight samples is greater than the motion limits selected during setup ZERO This annunciator is turned on to indicate that the weight displayed is within 1 4 division of the center of zero kg This annunciator is turned on to indicate the weight displayed is in kg kilograms POUNDS This annunciator is turned on to indicate the weig...

Страница 12: ...l the scale is powered up 2 Press the UNITS key until the desired weighing units is shown on the display the annunciators and or fraction for the desired unit are turned on 3 Press and hold the ON OFF key for approximately 2 seconds The scale will beep and the display will show LoC indicating the selected weighing unit is now locked 4 Once the weighing units are locked the scale will always power ...

Страница 13: ...osition Note that the blinking character is the cursor location of the value to be changed To exit setup press the ON OFF key at any prompt PhotoI LITE WAY Photo Eye With the display showing photoI press the ZERO key to show the current setting If the value displayed is acceptable press the ZERO key again to save it Otherwise use the UNITS key to step through the selections for a new value When th...

Страница 14: ...ate Press ZERO key to show current setting If value displayed is acceptable press ZERO key again to save it Otherwise use UNITS key to step through selections for a new value and then press ZERO key to save it Allowable values are a minimum of 1 sample per second to a maximum of 16 samples per second in one sample per second intervals UNITS Weighing Units Press ZERO key to show current setting If ...

Страница 15: ...t value and placement of this amount of test weights on the scale platform 1 Make certain the scale platform is empty and free of debris then place the desired amount of calibrated test weights on the scale platform It is recommended that a minimum of 50 of the scale s capacity be used but 70 to 100 is preferred 2 Press the ZERO key 3 Determine the exact amount of test weights to be placed on the ...

Страница 16: ...proper operation procedures been followed If problem persists the scale may need re calibration Contact your scale serviceman Error Messages DISPLAY POSSIBLE CAUSE CORRECTIVE ACTION UnSt This message indicates that motion is present when attempting to perform one of the following operations Power Up or Pressing the ON OFF key on the keypad Insure scale is on a stable vibration free level surface a...

Страница 17: ...2 6021 0300 SCW SOCKET HEAD CAP SCREW PZ3060 5 2 6610 2000 JACK SOCKET 6 6 6680 0004 WASHER LOCK INT TOOTH 6 Z P 7 4 6680 0045 SPACER PCB 6 X 250 8 2 6680 0052 WASHER LOCK 4 Z P 9 1 6980 0015 STRAIN RELIEF BUSHING SR 5N 4 BLACK 10 1 8528 B377 0A ZERO CABLE 11 1 8528 B378 0A LOAD CELL CABLE 12 1 8528 B379 0A DC POWER CABLE 13 1 8528 C365 0A BATTERY DOOR ASSEMBLY 14 1 8528 C366 0A ENCLOSURE WELDMENT...

Страница 18: ... HEAD 6 32 x 312 THMS 4 3 6680 0004 WASHER LOCK INT TOOTH 6 Z P 5 1 8528 B272 08 LABEL BATTERY REQ PZ2500 6 1 8528 B364 0A BATTERY DOOR WELDMENT 7 1 8528 B391 08 BATTERY RETAINER 8 1 8528 C374 0A BATTERY PACK ASSEMBLY 9 2 8555 B159 08 SPACER 758C MOUNT 1 6800 1045 AC ADAPTER 100 240VAC 12VDC 1 AMP 6 6800 0020 BATTERY NiMH 1 2V 2700mAH AA SIZE Included on PZ3060 Optional on PZ3015 PZ3015L PZ3030 No...

Страница 19: ...8528 M372 O1 Rev E PZ3000 Series 17 PARTS IDENTIFICATION PZ3015 Base Assembly ...

Страница 20: ...SSY 5 2 587R9378 LOAD CELL SPACER 6 2 6021 1124 10 32 X 75 SOC HD S S 7 1 6021 1258 10 32 X 375 SET SCW 8 2 6021 1074 10 32 X 5 FHMS S S 9 1 6560 0021 LOCTITE 10 1 593GR986 SERIAL TAG 11 4 6540 1004 RUBBER FOOT 12 1 6610 3000 CONNECTOR HOUSING 13 1 6980 0004 STRAIN RELIEF 14 1 8528 B392 0A CABLE LOAD CELL 9 FT 15 1 6610 5007 CABLE CLIP 16 1 8534 C623 0A SCALE BASE 17 4 6540 1058 RUBBER PAD 18 1 59...

Страница 21: ...8528 M372 O1 Rev E PZ3000 Series 19 PARTS IDENTIFICATION PZ3015L PZ3030 Base Assembly ...

Страница 22: ... B392 0A CABLE LOAD CELL 9 FT 8 4 6540 1004 RUBBER FEET STICK ON 9 1 6980 0004 STRAIN RELIEF 10 1 6610 3000 CONNECTOR PLUG 11 3 587R9378 SPACER LOAD CELL 13 2 6024 0037 LOCK WASHER 10 HELICAL 14 1 6021 2002 THUMB SCREW 10 32 X 3 4 15 1 8529 B045 08 LABEL REMOVE 16 1 593GR986 SERIAL TAG 17 1 6650 0087 STICKER MADE IN USA 18 2 6021 2001 CAP SCREW 10 32 X 1 SOCKET HEAD S S 19 1 6021 1258 SET SCREW 10...

Страница 23: ...8528 M372 O1 Rev E PZ3000 Series 21 PARTS IDENTIFICATION PZ3060 Base Assembly ...

Страница 24: ... 32 X 375 RHMS 11 4 6021 1429 1 4 20 X 0 75 SHCS 12 6 6021 1454 SCREW HEX HEAD 1 4 20 X 0 75 13 2 6450 0001 RUBBER FOOT 0 5 SQ X 0 23 HIGH WHT ADHES 14 4 6024 0037 WASHER LOCK 10 HELICAL SPLIT 15 10 6024 0040 WASHER LOCK HELICAL 1 4 S S 16 4 6540 1058 RUBBER PAD 17 4 6540 1130 LEVELING FOOT 18 7 6610 5007 CABLE CLIP 19 1 6680 1091 RUBBER GROMMET 20 1 8528 C381 08 INDICATOR MOUNTING BRACKET FRONT 2...

Страница 25: ...8528 M372 O1 Rev E PZ3000 Series 23 NOTES ...

Страница 26: ...ect labor of the technician at the job site This limited warranty honors only labor performed by Detecto authorized dealers This warranty does not apply to peripheral equipment not manufactured by Detecto this equipment will be covered by certain manufacturer s warranty only This warranty does not include replacement of expendable or consumable parts This does not apply to any item which has deter...

Страница 27: ...tion with the sale or use of the product Detecto will not be liable for consequential damages of any nature including but not limited to loss of profit delays or expenses whether based on tort or contract Detecto reserves the right to incorporate improvements in material and design without notice and is not obligated to incorporate improvements in equipment previously manufactured The foregoing is...

Страница 28: ...8528 M372 O1 Rev E PZ3000 Series 26 ...

Отзывы: