background image

 
 
 
 
 

ProDoc Series 

 

Digital Physician Scale 

PD100 
PD200 
PD300 

PD300DHR 

(Digital Height Rod) 

and 

PD300MHR 

(Mechanical Height Rod) 

 

Owner’s Manual 

 
 
 
 
 
 
 
 

CARDINAL SCALE MFG. CO. 

0044-M340-O1 Rev C 

PO Box 151 

 Webb City, MO 64870 

07/11 Ph: 

417-673-4631 

 Fax: 417-673-5001 

 

www.detectoscale.com 

0044-M340-O1 Rev C 

 ProDoc Series 

1

Technical Support: Ph: 866-254-8261 

 [email protected] 

Technical Support: Ph: 866-254-8261 

 [email protected] 

Summary of Contents for Detecto PD100

Page 1: ...l Height Rod Owner s Manual CARDINAL SCALE MFG CO 0044 M340 O1 Rev C PO Box 151 Webb City MO 64870 07 11 Ph 417 673 4631 Fax 417 673 5001 www detectoscale com 0044 M340 O1 Rev C ProDoc Series 1 Technical Support Ph 866 254 8261 techsupport cardet com Technical Support Ph 866 254 8261 techsupport cardet com ...

Page 2: ...0044 M340 O1 Rev C ProDoc Series 2 ...

Page 3: ...nical Height Rod Installation 14 BATTERY OPERATION 16 Installation Replacement 16 Low Battery 17 Automatic Shutoff 17 Sleep Mode 17 OPTIONAL AC POWER ADAPTOR 17 OPERATION 18 Keypad Functions 18 Annunciators 20 Basic Weighing 21 Weighing with Height and BMI Measure 22 With Digital Height Rod 22 With Mechanical Height Rod or No Height Rod 23 Storing Weight with the STORE Key 24 Recalling Weight with...

Page 4: ...sures necessary to correct the interference You may find the booklet How to Identify and Resolve Radio TV Interference Problems prepared by the Federal Communications Commission helpful It is available from the U S Government Printing Office Washington D C 20402 Request stock No 001 000 00315 4 All rights reserved Reproduction or use without expressed written permission of editorial or pictorial c...

Page 5: ...mber PD AC includes USA plug Also available UK plug PD UKPLUG or EU plug PD EUPLUG Display Five digit seven segment 1 0 inch 25 mm high LCD Operation Temperature 50 to 104 ºF 10 to 40 ºC Function Keys ZERO UNITS LOCK RELEASE BMI HEIGHT ENTER RECALL STORE and ON OFF Dimensions PD100 Display Base PD200 PD300 PD300MHR PD300DHR 5 25 H x 7 87 W x 2 125 D 134 mm x 200 mm x 54 mm 3 33 H x 12 5 W x 13 0 D...

Page 6: ...This page intentionally left blank 0044 M340 O1 Rev C ProDoc Series 2 ...

Page 7: ...ended that you read this manual before attempting to operate the scale this section is included to provide a condensed set of instructions on installing and using the scale At a minimum please make certain you read all of the caution and warning statements Step 1 Place the scale on the floor and then place the display at a convenient distance from the scale base Step 2 Turn the scale over on the f...

Page 8: ...k for easy viewing Wall Mounting 1 Choose the location to mount the display on the wall The location should be free of temperature extremes and water It should be where the display can be easily viewed not subject to direct sunlight and where the keypad is within easy reach of the operator 2 Make certain the structure and mounting hardware are of sufficient strength to support the display The moun...

Page 9: ...ur 4 slots on the back of the display and align them with the four 4 tabs on the Wall Bracket A Refer to Figure No 3 9 Insert the tabs into the slots and press together until the bracket locks to the back of the display 10 Referring to Figure No 4 align the cutout in Wall Bracket A with Wall Bracket B and gently pull down to secure the display to the wall Display Wall Bracket A Wall Bracket B Figu...

Page 10: ...r 4 feet from inside Wall Bracket A and install them in each corner of the bracket as shown in Figure No 6 3 Next locate the four 4 slots in the back of the display Refer to Figure No 7 4 Referring to Figure No 8 align and insert the tabs on the bracket with the slots in the display back and press together until the bracket locks to the back of the display Figure No 5 Figure No 6 Figure No 7 Figur...

Page 11: ...ide a condensed set of instructions on installing and using the scale At a minimum please make certain you read all of the caution and warning statements Step 1 Place the scale on the floor Step 2 Carefully turn the scale over with the display resting on the floor and then locate the battery access cover on the bottom of the scale Step 3 Remove the cover install six 6 AA size batteries1 and then r...

Page 12: ...This page intentionally left blank 0044 M340 O1 Rev C ProDoc Series 8 ...

Page 13: ...all plastic wrapping foam fillers and cardboard material from the scale base display and other components You should have the following components Scale Base Column with attached Display Column Cover M4x8 Machine Screw Hardware Pack containing 3 M4x8 Machine Screw M2 0x10 Column Cover Screw 3 M2 0x10 Column Cover Screw 4 M5x15 Machine Screws M5x15 Machine Screw 1 Philips Screwdriver Optional 9V AC...

Page 14: ...nsert the column into the hole on the column holder NOTE Make sure the preset cable passes through the slots in both the column the long slot and the column holder Figure No 11 5 Insert the M4x8 machine screw through the column holder into the column and tighten the screw to attach the column to the column holder Column Slot in Column Holder Preset Preset Cable Figure No 12 Slot in Column Cable Co...

Page 15: ...0 Screw M5x15 Machine Screws Column Column Cover Quick Start Step 1 Once the scale is assembled place it on the floor Step 2 Carefully lay the scale over on its side with the edge of the display resting on the floor and then locate the battery access cover on the bottom of the scale Step 3 Remove the cover install six 6 AA size batteries1 and then replace the cover Step 4 Return the scale to the u...

Page 16: ...et to height rod 4 M4x10 PM Screws bracket to column 4 Lock Washers bracket to column M4x4 5 Machine Screw M4x10 Machine Screw Lock Washer 1 Referring to Figure No 15 align the upper bracket with the holes in the height rod near the headpiece and install four 4 M4x4 5 PM screws to secure the bracket to the height rod 2 Next align the lower bracket with the lower holes in the height rod and install...

Page 17: ...lock washers to secure it to the column See Figure No 17 4 Remove the plastic cover on the back of the display exposing the modular connector socket Insert the modular connector of the DHR cable into the socket on the display until it locks in place It will click when locked in place Route the DHR cable through the two 2 plastic cable clips on the upper bracket See Figure No 18 Figure No 17 4 M4x1...

Page 18: ...w 8 32 Hex Nut M4x10 Machine Screw Wrench Lock Washer 1 Referring to Figure No 19 align a bracket with the holes near the top of the mounting bar and install two 2 8 32x1 2 Pan Head screws and 8 32 Hex nuts to secure the bracket to the mounti 8 32 Pan Head Screw ng bar g bar h hex heads are 1 8 from the bar 2 Next align the other bracket with the lower holes in the mounting bar and install two 2 8...

Page 19: ...n scale 3 Carefully lower height rod while keeping headpiece horizontal until it rests on top of patient s head If patient is shorter than 3 4 101 5 cm push latch to right while simultaneously pushing down on headpiece until headpiece rests on top of patient s head E C D Height Rod in rest Position B A A Latch B Headpiece C Inner Height Rod D Outer Height Rod E Measurement Read Line 4 Read height ...

Page 20: ...e the rectangular battery cover on the bottom of the scale 2 To install or replace the batteries first remove the battery cover by pushing in on the tab and lifting it up Refer to Figure No 23 Push in and lift here Figure No 23 Figure No 24 3 If installing new batteries proceed to step 4 If replacing the batteries remove all six 6 batteries from the battery holder and hen proceed to step 4 4 Insta...

Page 21: ...te the sleep mode has activated The sleep mode feature requires the scale to remain at the center of zero for a period of time to activate unlike the automatic shutoff feature which requires no motion or weight on scale The period of time for the sleep mode is also selected during the setup process of the scale and can be set for up to nine 9 minutes When weight is placed on the scale it will wake...

Page 22: ...This key is used to change the weighing units between pounds and kilograms For example with pounds displayed pressing this key will change the weighting units to kilograms NOTE This feature must be enabled during setup and calibration of the scale to be operational This key is used to lock and unlock the display If the HOLD feature was enabled during setup and calibration pressing this key will ca...

Page 23: ...ht pressing it again will display the Body Mass Index BMI calculation Pressing it a third time will return the display to the patient s weight In the Memory Function operation pressing the BMI HEIGHT ENTER key will signal the software that the desired MEM position has been selected and to store the current weight in that location The RECALL or STORE keys are used when performing the Body Mass Inde...

Page 24: ... annunciators are turned on when the displayed height measurement is in feet and inches HEIGHT This annunciator is turned on when the scale is in the height measurement mode WEIGHT This annunciator is turned on when the scale is in the weight only mode BMI Body Mass Index This annunciator is turned on when displaying the calculated body fat 1 2 3 4 The 1 2 3 or 4 annunciator will flash to show whi...

Page 25: ...t is active 6 Patient may now step on scale 7 Read and record weight displayed NOTE Press the LOCK RELEASE key when the STA annunciator is turned on to lock the current weight reading Once the weight has been recorded press the LOCK RELEASE key again to release the current weight reading Locked Released 8 Patient may now step off scale 9 To turn scale off press ON OFF key Display will show oFF and...

Page 26: ...ent weight reading Once the weight has been recorded press the LOCK RELEASE key again to release the current weight reading 8 Press BMI HEIGHT ENTER key 9 Grasp height rod at hinge pin see Figure No 28 and raise it well above patient s head and then lift headpiece to horizontal position 10 Carefully lower height rod until headpiece rests on top of patient s head 11 Read and record height of patien...

Page 27: ...I HEIGHT ENTER key 8 Scale display show 5 06 0 if units is pounds or 168 0cm if units is kilograms 9 Enter the patient s height by pressing the RECALL or STORE keys to increment or decrement to correct height NOTE If units is pounds height is increased or decreased by 0 5 If units is kilograms height is increased or decreased by 1 0cm 10 Press BMI HEIGHT ENTER key again and scale displays BMI Body...

Page 28: ...n to the MEM 1 position Position 2 Selected 4 When the desired MEM position has been selected press the BMI HEIGHT ENTER key to store the weight 5 Once the key has been pressed the software will capture the weight in this location As soon as there is no motion and weight is stable the MEM position annunciator will stop flashing and remain on to show a stable weight has been stored Weight Stored in...

Page 29: ...displayed 6 Press the RECALL key again The scale will return to displaying the current weight NOTE When recalling memory if a key is not pressed for 5 seconds the scale will automatically return to display the current weight 7 To store a new weight in the currently selected MEM position with the patient on scale and display showing patient s weight press the STORE key 8 Once the key has been press...

Page 30: ...and then press the BMI HEIGHT ENTER key to save it and proceed to the next prompt 1 Pounds Only 2 Kilograms Only 3 Pounds Kilograms 4 Kilograms Pounds NOTE If 1 or 2 Pounds only or Kilograms only are selected the UNITS key will be disabled ASH__ Automatic Shutoff If the value displayed is acceptable press the BMI HEIGHT ENTER key and proceed to the next prompt Otherwise press the RECALL or STORE k...

Page 31: ...ing and proceed to the next prompt To change a setting press the RECALL or STORE keys to select a new value and then press the BMI HEIGHT ENTER key to save the new value and advance to the next prompt USA_ Set Zero Limit This prompt selects whether the scale is used in the USA and has a zero limit or outside the USA with no zero limit If the value displayed is acceptable press the BMI HEIGHT ENTER...

Page 32: ...t NOTE By default the USA gravity constant will be used in non OIML applications CAL Y Calibrate Scale The display will change to show CAL Y To skip calibration and save the previous settings press the RECALL or STORE keys to select n n exit calibration and then press the BMI HEIGHT ENTER key The settings will be saved and calibration will be finished The display will show off and then shut the sc...

Page 33: ...s and hold the UNITS key and then press the ON OFF key 4 The display will turn on all digits and show the software version for a few seconds 5 Release all keys 6 The display will show CALCH for two seconds and then change to show the 3 digit calibration counter 7 Next the display will change to show SetCH for two seconds and then change to show the 3 digit configuration setup counter 8 To return t...

Page 34: ...ears of trouble free operation In spite of this troubles sometimes happen Before calling for service assistance you should make some initial checks to verify that a problem does exist The following describes several types of symptoms along with suggested remedies PROBLEM POSSIBLE SOLUTIONS Display does not turn on Battery Operation Check if batteries are installed and correctly Are batteries disch...

Page 35: ...ure extremes 4 DO NOT place scale in front of heating cooling vents 5 DO clean the scale and display with a damp soft cloth and mild non abrasive detergent 6 DO remove power before cleaning with a damp cloth 7 DO provide clean AC power and adequate protection against lightning damage 8 DO keep the surroundings clear to provide clean and adequate air circulation 0044 M340 O1 Rev C ProDoc Series 31 ...

Page 36: ...0044 M340 O1 Rev C ProDoc Series 32 ...

Reviews: