1.

 

Description. 

The 

WSD12-LVD

 is a 

datalogger

 with 3 input channels to acquire  global solar radiation, wind speed and direction, with storage 

functionality of samples acquired. 

 

2.

 

Configuration. 

The signal coming from the solarimeter, with W/m² as unit of measurement, is connected to the first input channel (

CH1

), by CH2 

channel  is  sampled  wind  direction  expressed  in  degrees,  meanwhile  on  channel  CH3  is  sampled  the  pulse  signal  coming  from 
anemometer to measure the wind speed in m/sec. 

NOTE

: wind direction is related to pole position: zero is obtained when the arrow tip and pole are pointed in the same direction, 

with opposite versus of pole fixing (

refer to picture 2

). Resetting procedure can be performed in any desired point in case clamp can’t 

be rotated.  

To perform this operation the arrow tip must be fixed in the desired position then issue the 6 + 6 command (

must be issued twice for 

confirmation

) to 

datalogger

The new position will be saved as “zero”.

 

 

 

 

Picture 1 - Product Image

 

Picture 2 - 

Position “zero”

 

Содержание WSD12-LVD

Страница 1: ...o the first input channel CH1 by CH2 channel is sampled wind direction expressed in degrees meanwhile on channel CH3 is sampled the pulse signal coming from anemometer to measure the wind speed in m sec NOTE wind direction is related to pole position zero is obtained when the arrow tip and pole are pointed in the same direction with opposite versus of pole fixing refer to picture 2 Resetting proce...

Страница 2: ...r Mode For this operation mode stand alone with data downloads through USB the connection with the PC and the WineCapManager running on it is necessary in order to modify the device s operation mode The sampling interval must be set with the device in STAND ALONE refer to 7 Stand alone USB datalogger installation mode and automatically the device s clock is aligned with the PC s clock in order to ...

Страница 3: ...l_R04 V4 8 4 Wireless device user interface The user interface consists of a virtual button that can be activated using the WineCapKey and of a two colors led To give a command user must approach the WineCapKey to the device s sensible area and keep it in that position the following picture Picture 4 WineCapKey positioning shows device s sensible points WineCapKey LED Picture 3 Device positioning ...

Страница 4: ...ary ENROLL command Also in this case the FACTORY RESET command must be given twice to confirm it At the command execution the led flashes as the PROBE DATALOGGER NOT ASSOCIATED status refer to WIRELESS MODE STATUS Table 5 flashes 3 flashes LOGGER NO WSN As the previous command but performs only the WSN deleting procedure and disassociate from the basestation The device enters in LOGGER STAND ALONE...

Страница 5: ...again when the device synchronizes with the WR12 repeater The link will not be reconfigured until completely lost by the device Because of this in some cases it could be necessary to force the operation In such cases put the device in STANDBY mode then run the TEST again refer to WineCap System User Manual R30 NOTE The display equipped datalogger WD04T is recommended to verify the signal quality d...

Страница 6: ...orresponds to the command number 4 and must be issued twice to confirm the operation Position the WineCapKey in the spot indicated in Picture 4 WineCapKey positioning and wait for four AMBER flashes then remove the WineCapKey from device Verify that the device asks for confirmation of STANDBY command with alternate GREEN RED flashing then position again the WineCapKey and wait for four flashes aga...

Страница 7: ...Case material ABS Mounting Fix on 4 points Connections Wireless USB Cable external diameter 4 7mm maximum Copper wire section 0 05 2 5mm 14 AWG Global solar radiation Transducer type Thermopile Global solar radiation Measure range 0 2 000 W m Global solar radiation Spectrum range 0 3µm 3µm Global solar radiation Zero offset 20 W m 200Wm Global solar radiation Measure resolution 8 W m Global solar ...

Страница 8: ...Strada Stratta 57 10090 CASTIGLIONE TORINESE TORINO ITALY VAT 04837130014 Phone 011 981 98 11 Fax 011 981 98 210 e mail info capetti it web www capetti it WA0152E_WSD12 LVD_User Manual_R04 V4 8 11 Mechanical dimensions Picture 9 Mechanical dimensions ...

Страница 9: ...11 65 CE that restricts the use of substances in the manufacturing of electronic devices The WEEE logo on the label indicates that this product is compliant with the WEEE EC Directive This symbol valid only in the European Union countries indicates that the product it is applied to MUST NOT be discarded with ordinary household or industrial waste but must be sent to an authorized reception point T...

Отзывы: