background image

 

WSD10TGII 

User Manual

 

 

 

 

 

WA0375E_WSD10TGII_User Manual_R08 

V4.6

 

 

CAPETTI ELETTRONICA s.r.l.  -   Strada Stratta 57 
10090 CASTIGLIONE TORINESE  -  TORINO  -  ITALY 
VAT 04837130014 - Phone 011.981.98.11 -  Fax 011.981.98.210 
e-mail [email protected]  -  web www.capetti.it

 

 

 

1/9

 

 

1.

 

Description. 

The 

WSD10TGII

  is  a  datalogger  with  4  input  channels  to  acquire  mechanical  schock,  inclination  and  temperature,  with  storage 

functionality of samples acquired. 

      

 

 

2.

 

“Sentry” feature.

 

The 

WSD10TGII

’s  main  feature  is  to  measure  landslides  and  or  avalanches  strikes  against  protection  barriers:  when  the 

acceleration, measured on channel 2 of the 

datalogger

,  exceeds  a user-set threshold, the 

WSD10TGII

 sends immediately to the 

basestation

 the information of “threshold trespass” and related warning.  

This information can be later processed according to the 

basestation

 model whose the 

datalogger

 is enrolled.  

For models provided with ModBus communication protocol (

MWDG-MB, MWLI-MB, MWLI-MB-4AO

), the information can be picked-

up directly on the ModBus register and managed through third party external intelligence (

PLC, PC, ecc.

).  

Concerning  the 

MWLI-MB-4AO  basestation

,  the  received  information  let  the 

basestation

  to  immediately  close  either  relay 

equipped onboard and physically  turn on an external alarm device. 

Please note: 

 

the 

datalogger

 must not be installed upside down, with ±180° tilt because the result means a discontinuity point and data 

acquired are wrong; 

 

the 

datalogger

  stores  an  acceleration  value  of  0  G  when  in  static  position.  During  the  threshold  setup,  the  gravity 

acceleration  must  be  considered  and  it’s  divided  by  three  axis  if  the 

datalogger

  installation  is  not  perfectly  vertical. 

Evaluating the tilt values, gravity force vector distribution can be rised again; 

 

the acceleration threshold must be set as “higher” and must have a minimum value of 1.1G. This value takes in account 
that the gravity acceleration constant is always present. The value is internally compared with accelerations measured on 
three  axis  and,  in  case  of  threshold  value  excess  even  just  one  axis,  the 

datalogger

  sends  the  event  warning  every  30 

seconds until the end of warning condition, warning condition event included; 

 

the warning value is the maximum value acquired sampling at 100Hz on three axis.

 

 

 

Picture 1 - Product Image

 

Summary of Contents for Wine cap WSD10TGII

Page 1: ...ird party external intelligence PLC PC ecc Concerning the MWLI MB 4AO basestation the received information let the basestation to immediately close either relay equipped onboard and physically turn on an external alarm device Please note the datalogger must not be installed upside down with 180 tilt because the result means a discontinuity point and data acquired are wrong the datalogger stores an...

Page 2: ...edure Otherwise in case the device is in FACTORY RESET mode refer to Picture 5 Status table Radio signal quality that means it s ready for connecting to an existing system in order to associate it make reference to the WineCap System User Manual R29 software manual Is necessary to use the WineCapManager software on the PC connected to the basestation that will be coupled with the device b USB Logg...

Page 3: ...etti it 3 9 5 Wireless device user interface The user interface consists of a virtual button that can be activated using the WineCapKey and of a two coloured led To give a command user must approach the WineCapKey to the device s sensible area and keep it in that position the following picture Picture 3 WineCapKey positioning shows device s sensible points Picture 3 Device positioning Picture 4 Wi...

Page 4: ...opped The sampling process and the radio are is turned off losing the connection to the network To reactivate a TEST command is necessary The STANDBY command must be given twice to confirm it at the first sequence the led flashes alternating RED and GREEN lights waiting for the second confirm sequence within 15 seconds At the command execution the led flashes as the STANDBY status refer to WIRELES...

Page 5: ...fferent command is associated to confirm the command the WineCapKey must be removed from the sensible area immediately after the number of flashes corresponding at the desired command The TEST corresponds to the second pulse and activate the Field Measurer function The device will give back the radio signal quality through led flashes WIRELESS MODE STATUS Table Flash count Wireless mode Status Rad...

Page 6: ...h count Stand alone mode STATUS 1 green flash 2 seconds long ACTIVE 2 red flashes 2 seconds long STANDBY Sequence of red flashes short 2 seconds long short FACTORY RESET INVALID datalogger clock PC connection required 9 Shutting off Reactivating the device If the device is shut off and left unused for a long time you can issue the STANDBY command refer to Picture 4 Commands table Its corresponds t...

Page 7: ...ght can be extended using WR12 battery powered routers Sealing IP65 Dimensions 90 x 120 x 50mm Weight 550g Case material ABS Mounting 4 points Connections Wireless USB Acceleration Transducer Type Triaxial accelerometer MEMS technology Acceleration Measure Range 16g Acceleration Measure Resolution 100mg Acceleration Alarms Common setup on three axis Inclination Transducer Type Triaxial acceleromet...

Page 8: ...l_R08 V4 6 CAPETTI ELETTRONICA s r l Strada Stratta 57 10090 CASTIGLIONE TORINESE TORINO ITALY VAT 04837130014 Phone 011 981 98 11 Fax 011 981 98 210 e mail info capetti it web www capetti it 8 9 11 Mechanical dimensions Picture 8 Mechanical dimensions ...

Page 9: ... 65 CE that restricts the use of substances in the manufacturing of electronic devices The WEEE logo on the label indicates that this product is compliant with the WEEE EC Directive This symbol valid only in the European Union countries indicates that the product it is applied to MUST NOT be discarded with ordinary household or industrial waste but must be sent to an authorized reception point The...

Reviews: