background image

Manuals and Documents

Brought to you by

Wechillit.com Ltd

WCI Group House

18 Pride Hill

Shrewsbury SY1 1DQ

Tel: 01743 289418

Fax: 01743 289416

Web: www.wechillit.com

Summary of Contents for Clipper 2 5L

Page 1: ...Manuals and Documents Brought to you by Wechillit com Ltd WCI Group House 18 Pride Hill Shrewsbury SY1 1DQ Tel 01743 289418 Fax 01743 289416 Web www wechillit com...

Page 2: ...ERVICING INSTRUCTIONS Calomax Limited Lupton Avenue Leeds LS9 7DD Tel 0113 249 6681 Fax 0113 235 0358 e mail service calomax co uk www calomax co uk Please read these instructions carefully before ope...

Page 3: ...ions For assistance in nding a suitable engineer in your area visit our website www calomax co uk contact our service department on 0113 249 6681 or e mail service calomax co uk CHECK LIST Before comm...

Page 4: ...is not suitable for installation where a water jet could be used Install the boiler in a position having adequate ventilation on a wall capable of carrying the working weight of the boiler A suitably...

Page 5: ...issioning cycle and water is drawn from the tap water will be replaced in short cycles Small amount of water and then heat The solenoid and element will never be on at the same time unless the boiler...

Page 6: ...he solenoid coil through overheat To re energise the solenoid the unit must be disconnected from the electrical supply and then switched back on after rst reinstating the water supply If the unit requ...

Page 7: ...switching on the electrical supply to the boiler The printed circuit board PCB controls the heating and lling functions of the boiler by monitoring the thermistor and level sensors The PCB also contr...

Page 8: ...udes nuts washers etc Exploded parts view for Clipper Range boilers To be read in conjunction with the spare parts list 25 26 or 27 depending on model 1 2 3 4 5 9 10 11 12 13 13 14 15 17 19 18 16 21 2...

Page 9: ...outlet WMPDTK2 to suit 7 5L 10L WMPDTK3 to suit 15L Swivel Nozzle attachment Non swivel nozzles also available please contact Calomax for further information Ref SN made to customer s dimensions x y F...

Page 10: ...10L 29 GASKET SET FOR MODELS 7 5L 10L GASKET SET FOR MODEL 15L BODY FOR MODEL 15L BODY LID GASKET FOR MODEL 15L X8 X8 X8 SPARE PARTS Refer to centre pages for location CASPCBT NBPRG NBE3HK 15PMFK 10P...

Page 11: ...DENSER EARTH ON BACKPLATE EARTH CONNECTION FOR OUTER CASING WHITE SHEATHING LIGHT PCB TRANSPARENT LIGHT UPPER MOST IN FASCIA RCD INCOMING SINGLE PHASE SUPPLY THROUGH A DOUBLE POLE ISOLATING SWITCH FUS...

Page 12: ...e page 12 Faulty wiring to thermistors faulty thermistors Temperature controller needs adjusting Element failed to earth Defective Printed Circuit Board De scale the boiler Particularly thermistor Rep...

Page 13: ...base warranty Some factors are beyond our control and would invalidate the warranty offered These include Incorrect installation High Low water pressure Incorrect voltage supply Accidental damage Lime...

Page 14: ...nutes 60 Minutes Average Flow rate from tap Standard nozzle 2 5 Litres Minute Voltage 220 240 V ac 50 60 Hz Power rating 3kW MAX PLEASE ENTER MODEL AND SERIAL NUMBER FOR FUTURE REFERENCE Note All meas...

Reviews: