background image

CT4196

User Manual

!

!

INPUT

EX

T.SUPPL

Y

OUTPUT

65VMA

X

600VCA

T III

600V

≤   ±  8V

9V

200mA M

AX

INT

O 1MΩ

CA

T III

Diff

er

en

tial M

ode

Common M

ode

DC+A

C peak

±35 

V @ 10x 

±35 

V

±18 

V @ 5x 

±3.5 

V @ 1x 

10x

OFF

PO

WER

Ov

er
Range

5x

1x

CT4196

60 MH

z D

iffer

ential P

rob

e

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Summary of Contents for CT4196

Page 1: ...A X I N T O 1 M C A T II I D iff e re n ti a l M o d e C o m m o n M o d e D C A C p e a k 3 5 V 1 0 x 3 5 V 1 8 V 5 x 3 5 V 1 x 1 0 x O F F P O W E R O v e r R a n g e 5 x 1 x C T 4 1 9 6 6 0 M H z...

Page 2: ...Inspect the Probe Inspect the probe and accessories for cracks and frayed or broken leads before each use If defects or damages are noted DO NOT USE the probe Dry Conditions Hands shoes floor and wor...

Page 3: ...authorized for use in contact with the human body or for use as a component in a life support device or system Do Not Substitute Parts Do not install substitute parts or perform any unauthorized modi...

Page 4: ...ended operation Compliance and Certifications CE Compliance This product meets the essential requirements of the applicable European Directives as follows z z 2014 30 EU Electromagnetic Directive EMC...

Page 5: ...eing put on the market after August 13 2005 and should not be disposed of as unsorted municipal waste Please utilize your local WEEE collection facilities in the disposition of this product and otherw...

Page 6: ...voltage mains installation POLLUTION addition of foreign matter solid liquid or gaseous ionized gases that may produce a reduction of dielectric strength or surface resistivity POLLUTION DEGREE 2 only...

Page 7: ...5x attenuation setting z z 15 MHz at 1x attenuation setting z z Up to 35 V DC AC peak common mode z z High accuracy 2 z z Power indicator LED z z Over range indicator LED Initial Inspection This unit...

Page 8: ...0 x 3 5 V 1 8 V 5 x 3 5 V 1 x 1 0 x O F F P O W E R O v e r R a n g e 5 x 1 x C T 4 1 9 6 6 0 M H z D i ff e r e n t i a l P r o b e Pincer Clips black and red Alligator Clips black and red Insulated...

Page 9: ...set the attenuation ratio to 5x and for voltages up to 35 V set the attenuation ratio to 10x 4 The power indicator LED should turn on 5 Plug the pincer or alligator clips onto the test leads and conne...

Page 10: ...5x 10x 0 5 V div 5 V div 50 10x 20x 0 5 V div 10 V div Table 1 Oscilloscope Readings Cleaning This probe does not require any particular cleaning If necessary clean the case with a soft cloth WARNING...

Page 11: ...50 dB 1 MHz Maximum Input Voltage 1x DC AC peak 3 5 V Maximum Input Voltage 5x DC AC peak 18 V Maximum Input Voltage 10x DC AC peak 35 V Absolute Maximum Rated Input Voltage each side to ground 600 Vr...

Page 12: ...IEC 61010 1 CAT II Mechanical Characteristics Weight 250 g Dimensions 195 x 55 x 30 mm BNC Cable Length 100 cm Input Leads Length 55 cm each Specifications are subject to change without notice To ens...

Page 13: ...t voltage in common mode is shown as follows 1KHz 1MHz 10MHz 10KHz 100KHz 100MHz Frequency 40 20 30 10 Volgage DC ACpeak CT4196 Maximum Input Voltage Derating Curve 35 25 20 15 Figure 2 CT4196 Deratin...

Page 14: ...sons will not be covered by this warranty Cal Test Electronics reserves the right to discontinue models change specifications price or design of this device at any time without notice and without incu...

Reviews: