background image

User Manual & 

Operating Instructions 

 
 
 
 
 

 

 

   

 

 

 

   

 
 
 

 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

DC-L Series 

 

CARAVAN – MARINE – RV - OFFGRID 

 
 

 

 

Summary of Contents for DC285L-X

Page 1: ...User Manual Operating Instructions DC L Series CARAVAN MARINE RV OFFGRID ...

Page 2: ...DC L range of fridges must be completed by a suitably trained professional only POWER SUPPLY Your fridge must be connected to a stable and regulated 12 V or 24 V DC power supply only The compressor will automatically detect which voltage is present adjust accordingly If you are using a generator or other power supply the output must be a pure sine wave Any fluctuations in generator current may dam...

Page 3: ...cavity OPERATING THE FRIDGE THERMOSTAT The cooling level can be set between 1 and 7 7 is the coldest setting and 1 is the warmest EQUALISING THE FRIDGE During the first 24 hours of operation your compressor will operate for longer than usual This process allows the internal air temperature food drinks condenser and insulation to equalise ENERGY SAVING TIPS Have a much ventilation as possible the m...

Page 4: ...inge Locate main door onto the bottom hinge Affix middle hinge to fridge cabinet Only tighten screws finger tight Locate freezer door onto the middle hinge Affix top hinge to fridge cabinet Only tighten screws finger tight Align the freezer door until it is square with the fridge cabinet Tighten top hinge screws fully Align the main door until it is square with the fridge cabinet Tighten bottom hi...

Page 5: ...evel to drop by as much as 2 V This occurs especially if the wiring in insufficient or if there is a loose connection somewhere If this occurs your fridge may exhibit a continuous start stop start pattern If so have your wiring checked by an electrician when under a 10 A load GENERAL TROUBLESHOOTING Check Correct power supply The built in fuse The voltage to the compressor is still 12V when a 10 A...

Page 6: ......

Page 7: ...Exterior Ventilation Interior Ventilation Option 1 Interior Ventilation Option 3 min 300cm2 min 50mm min 50mm min 50mm Interior Ventilation Option 4 Interior Ventilation Option 2 min 300cm2 min 200mm min 50mm min 50mm min 200mm ...

Page 8: ...stomer This warranty does not apply to damage or wear to the product caused by accident abuse misuse neglect unauthorized alteration or repair or if the product was not used in accordance with Bushman printed installation and operating instructions To obtain service under this warranty the defective product must be returned to Bushman together with a copy of the original purchase receipt Any produ...

Reviews: