USER'S
MANUAL

Mìøící a dílenské pøístroje / Multimetry

uvádí:

BRYMEN BM836, BM839

BRIGHT PEOPLE’S CHOICE

Summary of Contents for BM830 Series

Page 1: ...Eshop www emareg cz Email shop emareg cz USER S MANUAL Mìøící a dílenské pøístroje Multimetry uvádí BRYMEN BM836 BM839 BRIGHT PEOPLE S CHOICE ...

Page 2: ...oltage function on a known source such as line voltage to determine proper meter functioning The meter meets UL IEC EN61010 1 Ed 3 0 CAN CSA C22 2 No 61010 1 Ed 3 0 UL IEC EN61010 2 033 Ed 1 0 to Measurement CAT III 1kV and CAT IV 600V AC DC The accompanied test probe assembly meets UL IEC EN61010 031 Ed 1 1 to the same meter ratings or better IEC 61010 031 requires exposed conductive test probe t...

Page 3: ...fuse or circuit breaker in the building installation is applicable to test and measuring circuits connected to voltage MAINS installation Examples are measurements on distribu tion boards including secondary meters circuit breakers wiring including cables bus bars junction boxes switches socket outlets in the fixed installation and equipment for industrial use and some other equipment such as stat...

Page 4: ...t is excellent in detecting faulty contacts identifying potentiometer clicks and indicating signal spikes during adjustments 1 4 1 2 digits 20000 counts 3 5 6 digits 6000 counts selectable dual displays 2 Push buttons for special functions features 3 Selector to turn the Power On or Off and Select a function 4 Input Jack for mA µA function positive input 5 Common Ground reference Input Jack for al...

Page 5: ...arily to toggle the subject functions Last selection will be saved as power up default for repeat meas urement convenience For function press the button momentarily to select other ranges manually when needed For function default is set to 600V range to best cope with the measurements of most Variable Frequency Drives VFD Press the button momentarily to select1000V range when needed Turn Rotary Kn...

Page 6: ...ith flashing display backlightindicate a complete wire Such audible and visible indications improve continuity readabilities in noisy working environments Conductance is the inverse of Resistance that is S 1 or nS 1 G It virtually extends the Resistance measurements to the order of Giga Ohms for leakage measurements Using resistance continuity or nS function in a live circuit will produce false re...

Page 7: ...range to the 200 range then press the button momentarily The display sho Keep shorting the leads for further 3 seconds until the display shows zero The lead resistance is then temporarily compensated The compensation value stays until the next meter power reset and can be ashigh as 5 If you need a compensation value that is higher than that Relative Zero mode is recommended Press the button moment...

Page 8: ...age drop forwa rd biased for a good silicon diode is between 0 400V to 0 900V A reading higher than that indicates a leaky diode defective A zero reading indicates a shorted diode defective An OL indicates an open diode defective Reverse the test leads connections reverse biased across the diode The digital display shows OL if the diode is good Any other readings indicate the diode is resistive or...

Page 9: ...op www emareg cz Email shop emareg cz w w w e M A R e g c z Press the button momentarily to toggle the subject functions Last selection will be saved as power up default for repeat measurement convenience ...

Page 10: ...ection will be saved as power up default for repeat measurement convenience Note Be sure to insert the banana plug type K temperature bead probe Bkp60 with correct polarities You can also use a plug adapter Bkb32 Optional purchase with banana pins to type K socket to adapt other standard type K mini plug temperature probes ...

Page 11: ...utomatically after approximate10 minutes to extend battery life Press the button momentarily to select manual ranging and the meter will remain in the range it was in the LCD turns off Press the button momentarily again to select an adjacent range Press and hold the button for 1 second or more to resume auto ranging Relative Zero allows the user to offset the meter consecutive measurements with th...

Page 12: ...AC DC Current and Resistance functions Press turn on The meter beeps when a new MAX maximum or MIN minimum reading is updated Press the button momentarily to read the Real time MAX and MIN readings in sequence Press the button for 1 second or more to exit MAX MIN recording mode When activated Auto Power Off is disabled automatically Press button momentarily to activate CREST Instantaneous Peak Hol...

Page 13: ...ff feature Turn the rotary switch OFF and then back on to resume To avoid electrical shock disconnect the meter from any circuit remove the test leads from the input jacks and turn OFF the meter before opening the case Do not operate with open case Install only the same type of fuse or equivalent Accuracy is specified for a period of one year after calibration Periodic calibration at intervals of ...

Page 14: ...C LR6 Fuse F2 for input 0 4A 1000Vac Vdc IR 30kA F fuse or better Dimension 6 x 32 mm Fuse F3 forA input 11A 1000Vac Vdc IR20kA F fuse or better Dimension 10 x 38 mm Loosen the screws from the access cover of the case bottom Lift the access cover Replace the batteries or fuse Re fasten the screws ...

Page 15: ...Ed 1 0 IEC UL EN61010 2 033 Ed 1 0 IEC UL EN61010 031 Ed 1 1 and the corresponding CAN CSA C22 2 regulations to MeasurementCategories CAT III 1000 V AC DC and Category IV 600V AC DC µA mA 0 4A 1kV DC AC rms IR 30kA F Fuse or better A 11A 1kV DC AC rms IR20kA F Fuse or better V 1100V DC AC rms mV Others 1000 V DC AC rms 8kV 1 2 50 s surge Meets EN61326 1 2013 ACV of Model 836 in an RF field of1V m ...

Page 16: ...JackTM audible visible input warning Accuracy is reading digits number of digits or otherwise specified at 23 C 5 C less than 80 relative humidity True RMS voltage current accuracies are specified from 1 to 100 of range or otherwise specified Maximum Crest Factor 1 8 1 at full scale 3 6 1 at half scale and with frequency components fall within the specified frequency bandwidth for non sinusoidal w...

Page 17: ...0 0V 4 2 30d 199 99mV 3 1 9999V 19 999V 199 99V 1 8 40d 2 40d1 1000 0V Unspecified 199 99mV 3 1 9999V 19 999V 199 99V 2 40d Unspecified 1000 0V Unspecified Input impedance 10M 110pF nominal 1 Add 1 bandwidth 4kHz 5kHz 2 Unspecified forreadings 5 of range 3 Signal peak absolute values includingDC bias less than 1100mVpeak 4 40Hz 500Hz only for model 836 600 0V 1000V 4 5d 600 0V 1000V 2 5 5d 600 0V ...

Page 18: ...d 1 9999V 19 999V 199 99V 0 045 6d 0 09 6d 1000 0V 0 09 6d 0 18 6d Input impedance 10M 110pF nominal Model 839 Model 836 600 0 0 15 3d 0 3 3d 6 000k 60 00k 0 15 1d 0 3 1d 600 0k 0 3 1d 0 6 1d 6 000M 2 0 5 1d 0 7 1d 60 00M 3 1 5 3d4 6 2 3d4 6 60 00nS 3 2 0 10d5 6 1 Open Circuit Voltage 1 7VDC typical 2 Constant Test Current 0 2 A Typical 3 Constant Test Current 0 02 A Typical 4 Add 1 20M 5 Add 30d ...

Page 19: ...pical 2 Specified with input lead resistance been offset by or short feature 3 Constant Test Current 0 2 A Typical 4 Constant Test Current 0 02 A Typical 5 Add 2 operation temperature 35oC Continuity Threshold Between 20 and 350 Response time 30ms Audible Response Beep sound Visible Response LCD Backlight 2 700V 1 5 4d 0 4mA 2 8 VDC 20 00nF 1 8d 200 0nF 2 000 F 20 00 F 200 0 F 2000 F 1 2d 20 00mF ...

Page 20: ...for changes 5 C 2 Type K thermocouple range accuracynot included Model 839 Model 836 600 0 A 1 0 18 4d 0 36 4d 0 2mV A 6000 A 1 0 18 2d 0 36 2d 0 2mV A 60 00mA 1 0 18 4d 0 36 4d 3 0mV mA 600 0mA 1 2 0 3 3d 0 5 3d 3 0mV mA 6 000A 0 5 4d 0 6 4d 30mV A 10 00A 3 0 7 2d 0 8 2d 30mV A 1 A mA DC accuracies will be affected by extreme interior temperatures of the meter For rated accuracies allow 6 to 20 m...

Page 21: ... 20 minutes cool down interval after measuring A currents of 3 to 10A continuously 2 10A continuous up to ambient 35 oC 15 mins on per 5 mins off 35 oC 50 oC 10A to 20A for 30 seconds on per 5 minsoff Model 839 Model 836 40Hz 3kHz 600 0 A 6000 A 1 2d 1 2 2d 0 2mV A 60 00mA 600 0mA 1 3mV mA 6 000A 10 00A 2 1 4d 1 2 4d 30mV A 3kHz 5kHz 600 0 A 6000 A 2 2d Unspecified 0 2mV A 60 00mA 600 0mA 1 3mV mA...

Page 22: ...1 Unspecified 30mV A 1 10A continuous up to ambient 35 oC 15 mins on per 5 mins off 35 oC 50 oC 10A to 20A for 30 seconds on per 5 minsoff 199 99mV 600 0mV 40mV 6Hz 100kHz 1 9999V 6 000V 0 4V 10Hz 50kHz 19 999V 60 00V 4V 199 99V 600 0V 40V 10Hz 30kHz 1000 0V 1000V 400V 10Hz 5kHz VFD 600 0V 40V 10Hz 440Hz VFD 1000V 400V 10Hz 440Hz 199 99 A 600 0 A 40 A 10Hz 5kHz 1999 9 A 6000 A 400 A 19 999mA 60 00...

Page 23: ...ecified accuracy 12 counts 20000 count mode Specified accuracy 120 counts AC functions update interval 120ms nominal response to 85 For changes 350ms in duration and input 5 of range 6000 count mode Specified accuracy 30 counts 20000 count mode Specified accuracy 300 counts DC AC functions For changes 5ms in duration 6000 count mode only Specified accuracy 150 counts ...

Page 24: ...damaged by accident or abnormal conditions of operation or handling To obtain warranty service contact your nearest BRYMEN authorized agent or send the product with proof of purchase and description of the difficulty postage and insurance prepaid to BRYMEN TECHNOLOGY CORPORATION BRYMEN assumes no risk for damage in transit BRYMEN will at its option repair or replace the defective product free of c...