background image

1

912SC 92.1 AFUE

LEGACY

t

LINE SINGLE--STAGE

4--WAY MULTIPOISE

CONDENSING GAS FURNACE, SERIES A

Product Data

A11264

The 912S Multipoise Condensing Gas Furnace is part of the

Legacy

t

Line product offering. Sporting a PSC blower motor

and an Annual Fuel Utilization Efficiency (AFUE) of 92.1%, this

single-stage gas furnace provides efficient comfort for
homeowners. This Legacy Line Gas Furnace also features 4-way

multipoise installation flexibility, and is available in eight model

sizes. The 912S can be vented for direct vent/two-pipe, ventilated
combustion air, or single-pipe applications. A Bryant

R

Air

Conditioner or Heat Pump can be used to form a complete system.
All units meet California Air Quality Management District

emission requirements. These furnaces are approved for

Manufactured Housing (Mobile Home) applications. All sizes are
design certified in Canada.

STANDARD FEATURES

S

4-way multipoise design for upflow, downflow or horizontal
installation.

S

Optional through-the-cabinet downflow venting.

S

Installation flexibility with a 360-degree rotating elbow.

S

Ideal condensing furnace height 35” cabinet: short enough for
taller coils, but still allows enough room for service.

S

Silicon Nitride Perfect Light

t

Hot Surface Igniter.

S

Aluminized-steel primary heat exchanger.

S

Stainless-steel condensing secondary heat exchanger.

S

High-quality corrosion-resistant prepainted steel cabinet with
hemmed edges for safety.

S

Factory-configured ready for upflow applications.

S

Direct-vent/sealed combustion, single-pipe venting or ventilated
combustion air.

S

PSC blower motor, single-speed inducer motor, and single-stage
gas valve.

S

Self-diagnostics

S

Approved for Twinning applications (36060 through 60120
sizes, only).

S

Propane convertible (See accessory list).

S

Approved for Manufactured Housing/Mobile Home applications
with MH accessory kit.

S

Convenient Air Purifier and Humidifier electrical connections.

S

Residential installations may be eligible for consumer financing
through the Retail Credit Program.

S

Certified to leak 2% or less of nominal air conditioning CFM
delivered when pressurized to 1-inch water column with all
present air inlets, air outlets, and condensate drain port(s) are
sealed.

Use of the AHRI Certified 

TM

 Mark indicates a

manufacturer’s participation in the program.  For
verification of certification for individual products,
go to www.ahridirectory.org.

C E RT I F I E D

Summary of Contents for 912SC

Page 1: ...eight 35 cabinet short enough for taller coils but still allows enough room for service S Silicon Nitride Perfect Lightt Hot Surface Igniter S Aluminized steel primary heat exchanger S Stainless steel...

Page 2: ...product a design with more than ten years of field proven performance and success These innovations paired with the continuation of a crimped no weld seam create an efficient robust design for this e...

Page 3: ...970 2050 Cooling Capacity tons 400 CFM ton 2 5 2 5 2 5 3 5 4 4 5 3 5 5 5 350 CFM ton 2 5 3 3 4 4 5 5 0 4 0 5 5 5 5 Direct Drive Motor Type Permanent Split Capacitor PSC Direct Drive Motor HP 0 3 0 5 0...

Page 4: ...U 120 120 000 BTU 140 140 000 BTU Not all familes have these models 0 90 AFUE 2 92 AFUE 3 93 AFUE 5 95 AFUE 6 96 AFUE 7 97 AFUE Example of a Model Number A12374 FURNACE COMPONENTS RATING PLATE NOT SHO...

Page 5: ...Nat Gas LH32DB202 D D D D D D D D D Gas Orifice Kit 44 Nat Gas LH32DB200 D D D D D D D D D Gas Orifice Kit 45 Nat Gas LH32DB205 D D D D D D D D D Gas Orifice Kit 46 Nat Gas LH32DB208 D D D D D D D D...

Page 6: ...nge 3 5 397 1485 1470 1455 1430 1390 1340 1280 1205 1120 1035 Blue 3 2 5 426 1120 1110 1100 1090 1065 1035 990 935 870 805 Red 3 2 0 433 940 920 910 890 865 830 790 745 690 625 048100 SIDE BOTTOM Blac...

Page 7: ...Temp C Unit Size 40 000 BTUH 60 000 BTUH Uninsulated 3 8 in Insulation 1 2 in Insulation Uninsulated 3 8 in Insulation 1 2 in Insulation Pipe Dia mm 38 51 64 38 51 64 38 51 64 38 51 64 76 38 51 64 76...

Page 8: ...ize 40 000 Outlet choke required under 10 ft TEVL 60 000 80 000 100 000 120 000 140 000 Altitude meters Pipe Dia mm 38 51 64 38 5 64 76 38 51 64 76 102 51 64 76 102 64 76 102 64 76 102 0 610 6 26 57 6...

Page 9: ...eters of PVC ABS pipe VERIFY FROM VENT MANUFACTURER S INSTRUCTIONS Can this application use 60 mm O D polypropylene vent piping If not what size piping can be used Measure the required linear length o...

Page 10: ...PLY AIR A10490 MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS POSITION CLEARANCE Rear 0 0 mm Front Combustion air openings in furnace and in structure 1 in 25 mm Required for service 24 in 610 mm All Sid...

Page 11: ...1 2 YES YES NO YES 60 000 14 3 16 YES YES NO YES 17 1 2 YES NO NO YES 80 000 17 1 2 YES YES NO YES 21 YES YES NO YES 100 000 21 YES YES NO YES 120 000 24 1 2 YES YES NO YES INPUT CASING WIDTH INCHES...

Page 12: ...5 8 600 2 24 1 2 622 Furnace with or without Cased Coil Assembly or Coil Box 22 1 8 562 19 483 23 3 4 603 20 5 8 600 1 The plenum should be constructed 1 4 in 6 mm smaller in width and depth than the...

Page 13: ...SUPPLIED DISCONNECT AUXILIARY J BOX 24 V TERMINAL BLOCK THREE WIRE HEATING ONLY FIVE WIRE NOTE 1 NOTE 2 FIELD SUPPLIED DISCONNECT CONDENSING UNIT TWO WIRE FURNACE C O N T R O L R G COM W C R G Y GND...

Page 14: ...S IN INCH MM 22 2 7 8 7 8 22 2 POWER CONN AIR FLOW SEE NOTE 3 NOTES 1 Doors may vary by model 2 Minimum return air openings at furnace based on metal duct If flex duct is used see flex duct manufactur...

Page 15: ...accessory highly efficient Media Filter is available as an option _____________ Media Filter Casing Casing shall be of 030 in thickness minimum pre painted steel Draft Inducer Motor Draft inducer mot...

Page 16: ...e or change at any time specifications or designs without notice and without incurring obligations E2014 Bryant Heating Cooling Systems D 7310 W Morris St D Indianapolis IN 46231 Edition Date 10 14 Re...