Utilizing the extensive resources available to Bryant, a new stan-
dard of excellence has been achieved with the model 352AAV
Plus 90t

 

TM

 

 4-Way Multipoise Furnace.

The model 352AAV is a unique 4-way multipoise condensing fur-
nace with features like no other product in its class. The 352AAV
builds on the many Bryant successes in the furnace industry and
establishes a new standard for all high-efficiency gas furnaces.

 

FEATURES

Perfect Heat™ 

 

— The Plus 90t™ combines two heating stages to

vary  the  amount  of  gas  being  used  from  low-heat  to  high-heat
stage.  The  low-stage  operation  allows  longer  running  periods,
which helps maintain your most comfortable temperature, prevents
drafts, reduces noise, and enhances the air quality of your home.
During extreme cold, the high-heat stage will run to ensure that you
are still comfortable.

 

Primary Heat Exchanger & Secondary Heat Exchanger

 

 — The

primary  heat  exchanger  is  corrosion  resistant  and  maintains  a
proven  track  record  for  long-term  reliability  and  high-efficiency
performance.  The  secondary  heat  exchanger  is  built  with  a
patented lamination process that bonds a corrosion-proof lining of
polypropylene  to  a  heavy,  galvanized  steel  shell.  The  unique
secondary clamshell design allows wider spacing between cells for
reduced air resistance through the furnace, reduced load on the
blower motor, and reduced need for cleaning.

 

Perfect Light™ Igniter 

 

— Bryant’s unique SiN igniter is not only

physically robust but it is also electrically robust. It is capable of

running  at  line  voltage  and  does  not  require  complex  voltage
regulators as do other brands. This unique feature further enhances
the  reliability  of  Bryant’s  352AAV  gas  furnace  and  continues
Bryant’s tradition of providing a reliable and durable product.

 

Fan On 

 

Plus

 

™ 

 

— Improves comfort all year long by allowing you

to select the continuous fan speed right at the thermostat.

 

SmartEvap™ 

 

—  Allows  your  system  to  reduce  summertime

humidity levels by nearly 10% over standard systems.

 

Media Filter Cabinet

 

 — Enhanced indoor air quality in your home

is made easier with our media filter cabinet—a standard accessory
on all furnaces. When installed as a part of your system, this cabinet
allows  for  an  easy  and  convenient  addition  of  a  Bryant  high-
efficiency air filter.

   

Adaptive  Logic  Control  Board

 

  —  This  self-adjusting  control

board  contains  a  microprocessor  which  automatically  calculates
the precise amount of time your furnace should run and at what
speed it should run to obtain the best comfort and energy efficiency.
This control board also includes an extensive troubleshooting and
component test sequence that can monitor your heating system to
ensure that it is operating properly.

 

4-Way  Multipoise  Design

 

  — Allows the model 352AAV to be

installed in an upflow, downflow, or horizontal orientation. Factory
configured for upflow applications with only simple drain connection
changes required for conversion to downflow or horizontal.

 

Direct or Non-direct Venting 

 

— The 352AAV can be installed as

a  Non-Direct  1-pipe  vent  or  Direct  2-pipe  vent  furnace.  This
provides added flexibility to meet diverse installation needs.

 

Full Cabinet Insulation

 

 — This insulation completely surrounds

the  internal  furnace  casing  allowing  for  reduced  and  dampened
sounds and maintained efficiencies.

 

Two-Speed Inducer Motor 

 

— This motor works with the inducer

fan to optimize combustion efficiency and exhaust the flue gases
out of the house. The motor has two speeds and an incorporated
fan to keep the motor cool while reducing sound.

 

Permanent Split Capacitor (PSC) Blower Motor

 

 — The 

352AAV

has a PSC blower motor that has several preselected fixed speeds
which can be customized to duct work installation requirements.
The motor has a wide application of use, a basic control scheme,
and is extremely reliable.

 

Soft Motor Mounts

 

 — These motor mounts help to absorb shock,

decrease the vibration of the motor, and minimize noise.

 

Two Stage Gas Valve

 

 —The 352AAV has a 2-stage gas valve to

vary  the  amount  of  gas  being  used  from  low-heat  to  high-heat
stage.  The  low-stage  operation  allows  longer  running  periods,
which helps maintain your most comfortable temperature, prevents
drafts, reduces noise, and enhances the air quality of your home.
During the extreme cold, the high-heat levels will run to ensure that
you are still comfortable.

Summary of Contents for 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE 352AAV

Page 1: ...anced indoor air quality in your home is made easier with our media filter cabinet a standard accessory on all furnaces When installed as a part of your system this cabinet allows for an easy and convenient addition of a Bryant high efficiency air filter Adaptive Logic Control Board This self adjusting control board contains a microprocessor which automatically calculates the precise amount of tim...

Page 2: ...RY POWER ENTRY 7 8 IN DIA POWER CONN CONDENSATE DRAIN TRAP LOCATION DOWNFLOW HORIZONTAL LEFT 26 15 16 24 1 2 22 5 16 2 IN COMBUSTION AIR CONN 1 2 IN DIA GAS CONN 2 IN VENT CONN 1 2 IN DIA THERMOSTAT ENTRY 22 11 16 SIDE INLET 23 1 4 TYP SIDE INLET 1 1 4 1 OUTLET 26 15 16 28 1 2 22 5 16 19 13 16 5 8 5 16 1 39 7 8 22 1 4 TYP 11 16 7 16 24 3 16 BOTTOM INLET 18 1 4 22 11 16 2 IN COMBUSTION AIR CONN 1 2...

Page 3: ...ial La méthode d installation et la liste des pièces nécessaires figurent dans les instructions d installation Cette fournaise doit s utiliser avec la tuyauterie des nomenclatures 40 PVC PVC DWV CPVC ou ABS DWV et elle ne peut pas être ventilée conjointment avec d autres appareils à gaz Épaisseur de la construction au travers de laquelle il est possible de faire passer les tuyaux d aération admiss...

Page 4: ...91 4 91 4 91 4 91 4 91 4 Certified Temperature Rise Range F Low 20 50 30 60 30 60 25 55 30 60 30 60 High 30 60 40 70 30 60 45 75 30 60 40 70 Certified External Static Pressure ESP In wc Heating 0 12 0 15 0 15 0 2 0 2 0 2 Cooling 0 5 0 5 0 5 0 5 0 5 0 5 Airflow CFM Heating Low 680 790 775 1175 1205 1215 Heating High 1010 1130 1190 1315 1795 1770 Cooling 1275 1380 1565 1570 2035 2075 ELECTRICAL Unit...

Page 5: ... humidifier etc Length shown is measured 1 way along wire path between unit and service panel for maximum 2 voltage drop Required for installation on combustible floors when no coil box is used or when any coil box other than a Bryant CD5 or CK5 cased coil is used N A Not applicable ICS Isolated Combustion System For 048 and 060 airflow sizes only See kit installation instructions for details FACT...

Page 6: ...MINATION TYPE PIPE DIA IN PIPE DIA IN 1 2 3 4 5 6 2001 to 3000 60 000 2 Pipe or 2 in Concentric 1 1 2 1 1 2 17 12 7 NA NA NA 2 2 70 67 66 61 61 61 80 000 2 Pipe or 2 in Concentric 2 2 49 44 30 25 25 15 2 1 2 2 1 2 70 70 70 70 70 70 100 000 2 Pipe or 3 in Concentric 2 1 2 2 1 2 35 26 16 16 6 NA 3 3 70 70 70 70 66 61 120 000 2 Pipe or 3 in Concentric 3 NA 14 9 NA NA NA NA NA 3 63 62 62 61 61 61 3 no...

Page 7: ... 1 1 2 14 9 NA NA NA NA 2 2 60 55 54 49 48 47 80 000 2 Pipe or 2 in Concentric 2 2 41 36 23 18 17 8 2 1 2 2 1 2 70 70 70 70 70 70 100 000 2 Pipe or 3 in Concentric 2 1 2 2 1 2 29 21 12 11 NA NA 3 3 70 67 62 57 52 47 120 000 2 Pipe or 3 in Concentric 3 no disk NA 42 35 29 22 15 9 NA 3 53 52 50 49 48 47 4 no disk 4 no disk 70 70 70 70 70 70 ALTITUDE FT UNIT MAX INPUT RATE BTUH DIRECT VENT 2 PIPE ONL...

Page 8: ...ONLY NUMBER OF 90 ELBOWS TERMINATION TYPE PIPE DIA IN PIPE DIA IN 1 2 3 4 5 6 9001 to 10 000 60 000 2 Pipe or 2 in Concentric 2 2 45 40 38 33 31 29 80 000 2 Pipe or 2 in Concentric 2 2 30 25 14 9 7 NA 2 1 2 2 1 2 57 55 53 51 49 47 100 000 2 Pipe or 3 in Concentric 2 1 2 2 1 2 21 13 5 NA NA NA 3 3 54 49 44 39 34 29 120 000 2 Pipe or 3 in Concentric NA 3 39 37 35 33 31 29 4 no disk 4 no disk 10 5 NA...

Page 9: ...allowable pipe length as specified in Table 6 Insulation thickness based on R value of 3 5 per inch UNIT SIZE WINTER DESIGN TEMPERATURE F MAX PIPE DIAMETER IN WITHOUT INSULATION WITH 3 8 IN OR THICKER INSULATION 060 20 2 44 70 0 2 21 70 20 2 20 57 080 20 2 55 55 0 2 30 55 20 2 16 55 20 2 5 58 70 0 2 5 29 70 20 2 5 14 67 100 20 2 5 40 40 0 2 5 38 40 20 2 5 21 40 20 3 63 70 0 3 30 70 20 3 12 70 120 ...

Page 10: ...L APPLICATION OPTIONAL WIRE TIE GUIDES WHEN USED 1 2 1 3 4 1 3 4 FRONT VIEW SIDE VIEW FURNACE DOOR FURNACE DOOR CONDENSATE TRAP 78 1 4 26 4 FURNACE SIDE FURNACE SIDE 1 2 1 1 4 26 4 3 4 5 3 4 5 4 SIDE VIEW FRONT VIEW END VIEW FRONT VIEW 3 4 DOWNFLOW AND ALTERNATE EXTERNAL UPFLOW APPLICATIONS HORIZONTAL APPLICATIONS FIELD DRAIN CONN FIELD DRAIN CONN CONDENSATE TRAP INSIDE BLOWER SHELF ALTERNATE DRAI...

Page 11: ...KC Coil Box 15 1 8 19 16 3 4 20 3 8 3 21 Furnace with or without Cased Coil Assembly or KCAKC Coil Box 18 5 8 19 20 1 4 20 3 8 2 24 1 2 Furnace with or without Cased Coil Assembly or KCAKC Coil Box 22 1 8 19 23 3 4 20 3 8 1 C IN DIA B IN DIA PVC VENT EXHAUST 13 16 B IN DIA PVC INTAKE COMBUSTION AIR D E F A 11 2 A88207 LOCATING TAB LOCATING TAB 1 2 3 4 4 3 2 1 B D A97427 C A 1 1 4 TYP PLENUM OPENIN...

Page 12: ...540 490 04810 1 side or bottom High 1740 1705 1660 1615 1570 1500 1425 1355 Med High 1500 1470 1445 1410 1375 1330 1280 1210 Med Low 1340 1315 1300 1270 1235 1200 1140 1095 Low 1195 1175 1165 1130 1100 1070 1030 975 060100 bottom only High 2345 2265 2195 2110 2035 1940 1850 1745 Med High 2110 2065 2010 1945 1875 1800 1710 1615 Med 1810 1795 1770 1725 1680 1615 1545 1460 Med Low 1480 1465 1440 1415...

Page 13: ...UNIT AIRFLOW FRONT OF FURNACE A05065 COMBUSTION AIR INLET NON DIRECT VENT 1 PIPE APPLICATION COMBUSTION AIR PIPE DIRECT VENT 2 PIPE APPLICATION A C COIL OUTDOOR UNIT VENT PIPE HUMIDIFIER GAS FIRED WATER HEATER ELECTRONIC AIR CLEANER AIRFLOW FRONT OF FURNACE COMBUSTION AIR INLET NON DIRECT 1 PIPE APPLICATION A05064 ...

Page 14: ...T OF FURNACE A05066 DIRECT VENT 2 PIPE APPLICATION COMBUSTION AIR INLET NON DIRECT VENT 1 PIPE APPLICATION COMBUSTION AIR PIPE DIRECT VENT 2 PIPE APPLICATION VENT PIPE ELECTRONIC AIR CLEANER FURNACE CONDENSATE DRAIN AIRFLOW AIR CONDITIONING COIL REFRIGERATION PIPING FRONT OF FURNACE A05067 COMBUSTION AIR INLET NON DIRECT VENT 1 PIPE APPLICATION ...

Page 15: ... 15 352AAV ...

Page 16: ...e soft mount ed to the blower scroll to reduce vibration transmission Filters Furnace shall have reusable type filters Filter shall be ______ in x ______in An accessory high efficiency Media Filter is avail able as an option _____________Media Filter Casing Casing shall be of 030 in thickness minimum pre painted gal vanized steel Two Speed Inducer Motor Two Speed Inducer motor shall be soft mounte...

Reviews: