NOTE:

Read the entire instruction manual before starting the

installation.

This symbol

indicates a change since the last issue.

INDEX

Page

SAFETY CONSIDERATIONS..................................................1-2

Minimum Clearance to Combustibles......................................2

INTRODUCTION ..........................................................................2
LOCATION ................................................................................2-4

Air for Combustion and Ventilation .....................................2-3
Duct Work Recommendations ..............................................3-4

VENTING INSTRUCTIONS ........................................................4

Pre-Installation Vent System Inspection ..................................4
Masonry Chimney.....................................................................4
Factory-Built Chimneys............................................................4
Horizontal Venting....................................................................4

OIL BURNER ................................................................................4
OIL CONNECTIONS ....................................................................5
BAROMETRIC DRAFT CONTROL ...........................................5
ELECTRICAL................................................................................5
FILTERS .....................................................................................5-6

Filter Rack Installed on Side of Furnace .................................5
Filter Rack Installed on Return-Air End of Furnace...............5

CHANGING FROM UPFLOW TO HORIZONTAL...................7
OPERATIONAL CHECKOUT..................................................7-8

Start-Up .....................................................................................7
Recommended Installation Practices and

Combustion Check ..............................................................7

Fan Adjustment Check .............................................................8
Limit Control Check.................................................................8
For Year-Round Air Conditioning ...........................................8
Heating ......................................................................................8
Cooling ......................................................................................8
Constant Blower Switch ...........................................................8

MAINTENANCE......................................................................8-14

General ......................................................................................8
Oil Burner .................................................................................8
Heat Exchanger and Flue Pipe..............................................8-9
Blower Oiling and Removal.....................................................9
Keeping Filters Clean .............................................................10
Airflow Data ...........................................................................11
Dimensional Drawing .............................................................12
Barometric Damper Locations................................................13
Wiring Diagram ......................................................................14

USER’S INFORMATION ...........................................................15

Here’s How Your Heating System Works ............................15
Preparing Your Furnace For Operation .................................15
Lighting Your Furnace ...........................................................15
Turning Off Your Furnace .....................................................15

SAFETY CONSIDERATIONS

FOR YOUR SAFETY

DO NOT STORE OR USE GASOLINE OR
OTHER FLAMMABLE VAPORS AND LIQ-
UIDS IN THE VICINITY OF THIS OR ANY
OTHER APPLIANCE.

DO NOT ATTEMPT TO START THE BURNER
WHEN EXCESS OIL HAS ACCUMULATED,
WHEN THE FURNACE IS FULL OF VAPOR,
OR WHEN THE COMBUSTION CHAMBER IS
VERY HOT.

WARNING:

For use with grade 2 Fuel Oil maximum.

Do not use Gasoline, Crankcase Oil, or any Oil contain-
ing Gasoline! Failure to follow this warning can lead to
sooting, fire, explosion, and/or severe bodily harm.

CAUTION:

Never burn garbage or paper in the heating

system and never leave rags, paper, or any flammable
items around the unit.

CAUTION:

These instructions are intended to be used

by qualified personnel who have been trained in installing
this type of furnace. Installation of this furnace by an
unqualified person may lead to equipment damage and/or
a hazardous condition which may lead to bodily harm.

All local and national code requirements governing installation of
oil burning equipment, wiring, and flue connections must be
followed. Some of the codes (issued by the Canadian Standards
Association, the National Fire Protection Agency, and/or the
American National Standards Institute) that may be applicable are:

ANSI/NFPA 31

INSTALLATION OF OIL BURNING
EQUIPMENT

ANSI/NFPA 211

CHIMNEYS, FIREPLACES, VENTS,
AND SOLID FUEL BURNING
APPLIANCES

ANSI/NFPA 90B

WARM AIR HEATING AND AIR
CONDITIONING SYSTEMS

ANSI/NFPA 70

NATIONAL ELECTRICAL CODE

CSA B139

INSTALLATION CODE FOR
OIL BURNING EQUIPMENT

CSA C22.1

CANADIAN ELECTRICAL CODE

installation, start-up,
and operating instructions

UPFLOW/HORIZONTAL
OIL-FIRED FURNACE

Cancels:

II 363A-195-1

II 363A-210-1

8-96

363AAP

Series B

—1—

Summary of Contents for 363AAP

Page 1: ...NITY OF THIS OR ANY OTHER APPLIANCE DO NOT ATTEMPT TO START THE BURNER WHEN EXCESS OIL HAS ACCUMULATED WHEN THE FURNACE IS FULL OF VAPOR OR WHEN THE COMBUSTION CHAMBER IS VERY HOT WARNING For use with...

Page 2: ...r attic installation As this unit may be installed as an upflow or horizontal furnace it may be located in a basement on the same level as area to be heated suspended or in a crawlspace In any case un...

Page 3: ...g openings Screens used shall not be smaller than 1 4 in mesh and shall be readily accessible for cleaning If free area through a design of louver or grille is known it shall be used in calculating si...

Page 4: ...chimney is properly lined and sized per the applicable codes Refer to list of codes in Safety Consid erations section II MASONRY CHIMNEY This furnace can be vented into an existing masonry chimney Th...

Page 5: ...humidifier connection See Fig 9 These terminals are energized with 115v 0 5 amp maximum during any call for heat FILTERS It is NECESSARY THAT ALL FURNACES BE EQUIPPED WITH A FILTER An external filter...

Page 6: ...SCREW FILTER RACK FILTER ACCESS PANEL REAR OF FURNACE BASE PANEL FLUSH WITH REAR OF FURNACE SIDE FILTER RACK ALIGNMENT FILTER RACK BOTTOM FILTER RACK REAR PANEL REST FLANGE ON TOP OF BOTTOM PANEL FLA...

Page 7: ...ed with damper The draft regulator should be adjusted after furnace has been firing for at least 10 minutes and stack draft should be measured and set between 0 025 and 0 035 in wc The draft should be...

Page 8: ...User s Manual FAILURE TO FOLLOW THIS WARNING COULD RESULT IN POSSIBLE DAMAGE TO THIS EQUIPMENT SERIOUS PER SONAL INJURY OR DEATH WARNING Before performing any service functions unless operations spec...

Page 9: ...dous condition which could lead to bodily harm 15 Before reassembly heat exchanger and combustion cham ber should be inspected to determine if replacement is required After cleaning place combustion c...

Page 10: ...reduces efficiency of your system causes erratic performance of controls and could result in damage to motor or heating equipment 1 Inspect filters at regular intervals depending upon dirt conditions...

Page 11: ...0 7 0 8 0 9 1 0 060210 High 2485 2395 2305 2250 2145 2075 1975 1885 1780 1675 Medium 2195 2125 2060 1990 1915 1860 1785 1700 1620 1525 Low 1640 1590 1540 1515 1460 1410 1350 1275 1190 1075 NOTES 1 Air...

Page 12: ...DUCT CLEANOUT PORTS CLEANOUT PORTS A96336 DIMENSIONS IN UNIT SIZE UNIT DIMENSIONS DUCT SUPPLY OPENING FLUE DIAMETER SIDE RETURN OPENING END BOTTOM RETURN OPENING SIDE RETURN DUCT SIZE END BOTTOM RETUR...

Page 13: ...Fig 8 Barometric Damper Locations A95117 FIG A FIG G FIG D FIG L FIG B FIG C FIG J FIG H FIG K POOR WRONG WRONG WRONG WRONG WRONG BAROMETRIC DAMPER LOCATIONS GOOD LOCATIONS BAD LOCATIONS 13...

Page 14: ...ING MUST CONFORM TO CURRENT CSA 22 1 CANADIAN ELECTRICAL CODE PART 1 AND OR LOCAL CODES 3 IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED IT MUST BE REPLACED WITH WIRING MATE...

Page 15: ...fore attempting to put your furnace into operation for the heating season you should perform the following procedures WARNING If you do not follow these instructions exactly a fire or explosion may re...

Page 16: ...eo based formats and materials All include video and or slides plus companion book Classroom Service Training plus hands on the products in our labs can mean increased confidence that really pays divi...

Reviews: