Page 1: ...d Operation Manual BRG Precision Products 600 N River Derby Kansas 67037 http www brgproducts com sales brgproducts com 316 788 2000 Fax 316 788 7080 Updated 9 4 2018 Our mission is to offer innovative technology solutions and exceptional service ...

Page 2: ...ION 12 TIMER CONFIGURATION EXAMPLES 16 UP DOWN COUNTER CONFIGURATION 23 COUNTER CONFIGURATION EXAMPLES 24 ALARM CONFIGURATION 25 ALARM CONFIGURATION WORKSHEET 26 INFRARED REMOTE CONTROL 27 MEGA TIGER PROCESSOR CONFIGURATION MENU 28 ANALOG CLOCK OPERATION 12 INDEX ERROR BOOKMARK NOT DEFINED ...

Page 3: ... field troubleshooting of the Product under the terms of the Agreement if and not limited to a the Product has been misused neglected improperly installed physically damaged or altered either internally or externally or damaged from improper use or use in an unsuitable environment b the Product has been subjected to fire splashed water unless specifically ordered to be water resistant submersion i...

Page 4: ...ment supplement consent or waiver express or implied to or of any provision of this Agreement will be effective unless in writing signed by the parties hereto and then only in the specific instance and for the specific purpose given 10 Assignment The Customer may assign or transfer this Agreement provided BRG Precision Products Inc is advised by the Customer in writing of such assignment and the n...

Page 5: ...uct purchase price The term of this service ends when the warranty expires This service may be repurchased for 10 of the product purchase price when a two year extended warranty is purchased The product replacement service is only available on selected models 30 Day Return Policy No returns will be accepted without prior written authorization of BRG Incorrect merchandise received will receive prom...

Page 6: ...ng from any sale by BRG and customer and Buyer consent to personal jurisdiction of the federal and state courts located in Sedgwick County Kansas If legal action is brought by BRG for the collection of any amount owed or due to any other dispute the prevailing party will be entitled to recover its reasonable attorneys fees and costs incurred These items constitute the entire agreement between BRG ...

Page 7: ...l to comply with any of the terms and conditions of the Agreement Upon termination of this license for any reason you agree to return or destroy all copies of the software This Agreement constitutes the entire agreement and understanding between the parties and supersedes any prior agreements representations or understandings whether oral or written relating to the Software This Agreement shall be...

Page 8: ...tire agreement and understanding between the parties and supersedes any prior agreements representations or understandings whether oral or written relating to the Software This Agreement shall be governed by the laws of the State of Kansas Limited Warranty BRG Precision Products Inc warrants that the processors or memory use to store the software is free from physical defects in material and workm...

Page 9: ...econd due to gradual slowing of the earth s rotation Once the adjustment date is known the clocks can be configured well in advance to implement the leap second on the appointed date Leap second adjustments occur on average about every 4 5 years The frequency drift of each oscillator is measured at the factory The clock is configured with this value so it can automatically perform very small adjus...

Page 10: ...ctable Operation modes Real Time Up Timer Down Timer Up Counter Down Counter Event Timer Environment 32 degrees F to 120 Degrees F Humidity 0 to 95 non condensing Battery Backup 20 year Rechargeable Super Capacitor to maintain the time during loss of power Clock Accuracy Two parts per billion or about one second in 20 years ...

Page 11: ...ck Simply drive the appropriate number of screws into the wall and hang the clock on the screws Secure eyelet attachments are also available where a more secure mount is required The standard U S power configuration consists of a wall mount AC adapter This adapter drops the voltage down to a Class 2 voltage The power wire may be cut extended and or and rerouted through walls as pictured below Powe...

Page 12: ...ou just need to correct the time then clock on the button Send UTC Time Only If you need to change the display rules then make changes as needed using drop down boxes on the right side of the screen Then click on the button Send UTC Time With Rules The top text line PC data send to the clock display data going from the PC to the clock The next text line down Clock processor data sent to the PC dis...

Page 13: ...13 The above screen shot shows data that was send to the clock as well as data being send from the clock to the PC The time display rules are also displayed ...

Page 14: ...the Down button to decrement the time The longer you press the button the faster the clock will move Some models have these buttons temporarily disabled Configuration Menu The Mode Up and Down buttons are used to select various operating modes and parameters The values of the Mode Up and Down buttons will change with increasing speed the longer the buttons are held down Pressing the buttons quickl...

Page 15: ... and values Press the Mode button again to exit the current mode The mode change function will timeout and return to normal time display mode after 60 seconds of inactivity To return to normal time display mode Press the Timer Control Button or change the mode number to zero or allow the menu system to timeout ...

Page 16: ... timer operation To determine the timer direction press the Up button to determine if the timer is in the Up or Down direction The simple timer button operation supports display modes 1 2 10 12 13 21 22 and 27 Setting Mode 13 1 will stop a countdown timer when 0 is reached Setting Mode32 17 1 will cause a down timer to reverse direction at 0 Up timer starting at zero No upper time limit Display mi...

Page 17: ...splay to minutes and seconds reset the timer start counting up from zero Pressing the code blue button again will have no effect until the timer is reset back to real time Press the reset button once to stop the timer Pressing the reset button again will have no effect unless it is held down for more than five seconds at which time it will return to real time display The display will remain frozen...

Page 18: ...g Elapsed days since last accident or incident on a four digit display Up timer starting at 12 00 July 10 2000 This assumes the starting date is older than the current date 1 Mode 9 12 00 set starting hour and minutes 2 Mode 32 18 1 enable auto timer restart after power failure 3 Mode 44 1 07 10 starting month and day 4 Mode 44 2 2000 starting year Elapsed days hours minutes and seconds since last...

Page 19: ...inutes 6 Mode 10 00 set the end seconds default 7 Mode 37 34 21 display days elapsed on the leftmost four digits default 8 Mode 37 35 2 display hours and minutes on the center four digits default 9 Mode 37 36 11 display seconds and hundredths on the rightmost four digits 10 Mode 26 1 4 flash the display full on and off at a rate determined by the alarm pulse rate mode 32 13 11 Mode 32 13 10 flash ...

Page 20: ...or five seconds 20 Mode 43 5 20 Blink the display twenty times per second Down timer starting at ten minutes and counting down to zero then stopping Flash the display for five seconds when the timer stops Display minutes and seconds on a four digit display 1 Mode 23 1 24 display to 24 hour format 2 Mode 5 5 set alarm duration to 5 seconds this also controls the length of time to flash the display ...

Page 21: ...n light goes out and the yellow light illuminates When the timer is stopped or paused the red light illuminates 1 Mode 7 0 01 timer Starting hours and minutes 2 Mode 8 30 timer Starting seconds 3 Mode 14 3 set to down timer mode 4 Mode 20 1 12 display minutes and seconds 5 Mode 32 26 2 enable three light operation 6 Mode 43 1 4 enable optional secondary channel for warning light 7 Mode 43 3 30 tim...

Page 22: ... will switch from real time to countdown timer at 11 59 40 PM and countdown starting at 00 00 20 At 00 00 10 the display will blink until it stops at 00 00 00 At this time the display will switch to 2006 To restore from test mode cycle power to the display Then set Modes 7 1 00 8 0 28 1 59 Or restore the original display configuration by restoring customer defaults The following configuration can ...

Page 23: ...pear on the display If the month day appears press mode again to return to the mode one display Press the Up button until you reach Mode 14 Once at mode 14 press Mode to display the current operating mode Using the Up or Down buttons select mode 4 for up count or mode 5 for down count Press the Mode button to exit back to the previous level Press the Down button to move to 0 which will exit to nor...

Page 24: ... increment each time a product is produced The goal counter will auto increment so that the count at the end of the day will reflect the total goal for the day The actual count is configured the same as a simple counter However the goal counter will be configured to automatically increment Pressing the Up button will pause the goal counter during lunch or other break periods When the counter is pa...

Page 25: ...ned in flash memory which does not lose its memory when power is lost When power is applied to the clock all displays will illuminate and display the time s as configured When clocks are synchronized using serial wire sync slave clocks incorporating an alert horn can be configured to follow the schedule of a single clock This allows the alarm schedule in a single clock to control the alert horns o...

Page 26: ...Mode 5 Alarm Output Duration Mode 30 Individual Alarm Output Duration Mode 32 13 Alarm Pulse Control Mode 34 Individual Alarm Pulse Control Mode 38 Alarm Schedule Number Default 0 Mode 49 Toggle Alarm on off 1 on 2 off 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 ...

Page 27: ...s and optional for other models It can be used to control real time displays timers and counters The remote can also be used to access and change the clock s configuration The remote control receiver must be factory installed The Mega Timer processor does not support Timer Counter operation ...

Page 28: ...e is changed press Mode to back out of the item and move to another item or press the Timer Control button to save and exit the menu system Pressing the Timer Control button at any time will save your changes and exit the menu system Pressing the Mode button while a parameter value is displayed will back up one level Press Up or Down to move to the next mode item Pressing the Down button until mod...

Page 29: ...Timer Control buttons during power up First Menu Level Mode Number Second Menu Level Value Range Mode Description and Instructions 0 N A 00 00 to 23 59 Exit Menu System Simply press the Up button to advance the time or the Down button to decrement the time The longer the buttons are held down the faster the time will change Pressing the Timer Control button will also exit the menu system 1 N A 01 ...

Page 30: ... minutes This value determines the optional ending hours and minutes of the elapsed timer The display must be placed in 24 hour mode i e 23 1 24 otherwise zero will appear as 12 00 10 N A 00 to 59 Ending Time seconds This value determines the optional ending seconds of the elapsed timer 11 N A 9999 to 9999 Beginning Count This value determines the starting count for the event counter 12 N A 9999 t...

Page 31: ...wer four digits of Modified Julian date 8 x j j j upper three digits of Modified Julian date 9 xxxx blank display 10 xx ss xx seconds where xx is blank 11 ss 99 seconds hundredths of seconds 12 mm ss minutes seconds 13 bs sb seconds centered in a four digit display 14 dd dy day of the year plus last digit of the year 15 yddd last digit of the year plus day of the year 16 nnxd nn number of GPS sate...

Page 32: ...n to min sec when hrs 0 55 dd hh two digit days and hours no colon 56 hh mm Sunrise hours minutes 57 hh mm Sunset hours minutes 58 hh mm Sunrise hours minutes with leading zero no colon military format 59 hh mm Sunset hours minutes with leading zero no colon military format 60 wwdd Elapsed weeks 0 99 and days 0 7 65 9999 Elapsed minutes set Mode 37 6 2 or 3 66 9999 Elapsed seconds set Mode 37 6 2 ...

Page 33: ...er defined rule see also Mode 52 and Mode 45 32 Mode 45 33 22 user defined rule see also Mode 52 and Mode 45 34 Mode 45 35 23 user defined rule see also Mode 52 and Mode 45 36 Mode 45 37 24 user defined rule see also Mode 52 and Mode 45 38 Mode 45 39 25 1 24 display 1 15 Individual Numeric Zone Intensity default 0 This value determines the intensity in 15 steps for 1 through 24 numeric displays Th...

Page 34: ...n to turn off alarm before the predefined alarm duration has expired See Mode 34 to activate the alarm at sunrise and or sunset See also Modes 28 29 and 59 In Tiger version 3 75 and later the number of alarm entries has expanded from 100 to 1000 The 1000 alarm entries are stored in 10 different schedules of 100 entries each When Mode 37 1 0 alarm schedules will automatically change depending on th...

Page 35: ...eeds to be longer or shorter than other alarm tones A value of zero allows Mode 5 to control alarm output duration For extended alarm duration beyond 99 seconds see Mode 45 15 This mode is a multiplier for the alarm duration setting It allows an alarm duration up to 12 days See also Mode 32 13 Mode 34 for pulse alarm operation and Mode 37 56 for wireless alarm systems 31 1 24 0 7 Individual Numeri...

Page 36: ...ters continuously See also Mode 51 7 Mode 32 15 must be greater than 0 4 blink colon once per second when sync is lost must use display mode 2 GPS IRIG B Ethernet Setting Mode 51 7 n 16 where n is the alpha character position will blink one or more alpha characters once per second Mode 51 7 is used to indicate which character positions are to blink If no sync source is used setting Mode 32 2 4 wil...

Page 37: ...own 32 6 0 3 External Timer Control Line 0 momentary contact closure default 1 or 2 constant contact closure 3 one time start from real time 0 A momentary contact closure will switch the display from real time to timer mode reset the timer then starts the timer running Each time the code blue line is pulsed the timer resets and restarts A value of either 1 or 2 will cause the timer to run as long ...

Page 38: ...nable counter timer alarm 1 disable counter timer alarm 32 11 0 1 2 Mode and Display Format Switching Over Serial Sync Line 0 disable auto mode and format switching from serial data received default 1 enable operating mode and display format switching 2 enable operating mode switching only 5 Low speed IR remote control test Use the control buttons to set this Mode 32 11 5 not the remote A value of...

Page 39: ...ttings If this setting is 0 when the alarm sounds it will remain on for the entire selected alarm duration period A value of 1 94 determines the number of times the alarm is pulsed per second For example if the alarm duration is set for three seconds and Mode 32 13 is set for 2 pulses per second the alarm will turn on and off six times throughout the three second alarm duration period See also Mod...

Page 40: ...Examples 0 Serial sync transmits or receives on SRST port 0 Serial sync receives on GPS port Ethernet sync transmits on SRST port 2 GPS receives on GPS port and serial sync transmits receives on SRST port 4 IRIG B receives on GPS port and serial sync transmits on SRST port 7 Serial sync transmits on GPS port Ethernet sync receives on SRST port use the clock s control buttons Once set the date will...

Page 41: ... time and begin displaying the elapsed time from the target time then set Mode 32 17 1 This will enable the auto reverse feature Mode 13 is ignored when Mode 32 17 1 Mode 32 21 allows time updates from an external source to maintain the accuracy of a long duration timer See also Mode 37 49 for displaying days and hours on an alpha display 32 19 1 24 Timer Time Zone Applies only when Mode 32 18 1 T...

Page 42: ...ng normal display operation press and hold the TC button for about 4 seconds Once zone 1 display blinks release the TC button to toggle the timer operation To determine the timer direction press the Up button to determine if the timer is in the Up or Down direction The simple timer button operation supports display modes 1 2 10 12 13 21 22 27 46 and 48 Setting Mode 13 1 will stop a countdown timer...

Page 43: ...Zero Blanking on Selected Display Modes 0 disabled 1 enabled default The effected display modes include 4 5 6 7 17 19 21 22 23 30 37 52 55 and some menu functions This mode also controls the leading zero blanking for the special characters of digital alpha lettering See also mode 20 31 32 29 0 7 Reset and Initialize Display Drivers This mode periodically resets and initializes numeric display driv...

Page 44: ...e Color to Indicate Nighttime for each respective time zone Default 7 For intensity the range is 1 15 For color the range is 1 green 2 red 3 blue 4 yellow 5 magenta 6 cyan 7 white See also Modes 32 35 Modes 61 62 63 64 and Display Modes 56 57 58 and 59 32 37 0 1 Return to Real Time from Timer Mode 0 disabled default 1 Pressing the timer control while the timer is stopped or paused will return the ...

Page 45: ...ing Message Command Repeater 0 Moving Message commands are ignored 1 The moving message data without header address and footer is sent out the GPS port Data received on the SR ST port will only be sent out the GPS port if the address received equals zero or the address received equals the address set in mode 32 42 default Tiger version 4 06 or later Increase the inter packet delay in the Windows c...

Page 46: ...urly 5 reset c 5 and a 4 if no time update is received for one hour default 6 reset c 5 if no time update is received for one hour 32 47 0 3 Repeat Clock Control Commands Control commands coming in the SR ST port are repeated out the ST port GPS port or both 0 disabled default 1 SR ST port 2 GPS port 3 both 32 48 0 1 Ethernet Control Port 0 SR ST port default 1 GPS port For example if an Ethernet ...

Page 47: ...hen the Down button is pressed just like the slave clock Pressing the Timer Control button will simulate pressing the Timer Control button on the slave clock s The slave clocks must be configured as timers and are typically configured identically as the master except for Mode 32 51 See Mode 37 38 to increase timer accuracy 32 52 0 1 2 Display Colon 0 disabled 1 default enable colon in display mode...

Page 48: ... 8 10 12 1 4 16 18 20 2 2 GPS Serial Port Speed default 14 9600 baud Mode 32 15 9 to enable 5 300 Baud 6 600 Baud 8 1 200 Baud 10 2 400 Baud 12 4 800 Baud 14 9 600 Baud 16 19 200 Baud 18 38 400 Baud 20 76 800 Baud 22 153 600 Baud 32 58 0 1 Alpha Digital Lettering Menu System 0 disabled default 1 enabled This mode displays the menu system on the digital alpha numeric lettering in addition to the no...

Page 49: ...th digital lettering and IRIG B on the GPS port can repeat all commands received on the SR port out the ST port to other clocks and also send time out the ST port For a clock system it is recommended to set Mode 32 60 to 2 to immediately repeat the data Each clock will regenerate the data stream and no delays will be introduced For configurations where the local clock must transmit as in the case ...

Page 50: ...quator including leap years 32 67 0 9 Daylight Saving Time Begin Hour Offset Default 2 default 2 for 02 00 This mode determines the hour to switch between standard and DST for custom DST rules both North and South of the Equator including leap years 32 68 0 5 Time Reception Port Control 0 default receive time on both ports if configured otherwise does not receive remote GPS time packet either over...

Page 51: ... sync transmissions from going out the ports that could interfere with other devices attached to the port For example a clock configured with Ethernet on the SR St port and 900 MHz transmitter on the GPS port should only send time sync out the GPS port not the SR ST port Therefore Mode 32 70 should be set to 2 32 81 0 3 Ultra High Precision Oscillator Support 10 MHz oven or Rubidium oscillator Ove...

Page 52: ...han 0 and less than 50 will add a leap second on June 30 at 23 59 59 UTC of the designated year To add a leap second in December instead of June add 50 to the two digit year For example to add a leap second on December 31 2015 enter 65 The leap second will be added on December 31 at 23 59 59 UTC 2015 A value of 99 will add a leap second on the current day at 23 59 59 During the change at midnight ...

Page 53: ...Alarm Pulse This Mode sets the number of times the alarm is pulsed per second for each alarm setting It overrides Mode 32 13 all alarm pulsing 0 disable individual alarm output pulsing default 1 94 alarm pulses per second for individual alarm settings If this setting is 0 when the alarm sounds and Mode 32 13 0 the alarm will remain on for the entire selected alarm duration period A value of 1 94 d...

Page 54: ...elapsed hours Starting value 9999 to 9999 hours Pressing the Down reset button resets the day or hour counter to the value set in Mode 35 0 default See also Mode 51 See also Mode 37 49 for displaying days and hours on an alpha display Direction reverse in medium duration timers requires version 4 50 or later 36 1 24 Display format number Timer Control Display Format When the code blue line is enab...

Page 55: ...Elapsed Days and Hours Modifier 0 true elapsed time in days where one day equals 24 hours or 3600 minutes or 86 400 seconds 1 default causes the elapsed day counter to always change at 00 00 midnight regardless of the number of hours elapsed When displaying elapsed hours 1 hours will increment at 00 minutes regardless of the time that has elapsed 2 display elapsed seconds up to 99 999 999 using co...

Page 56: ...e than 5 seconds returns the timer to real time display 37 11 0 1 Timer Reset Mode 0 When the timer is reset the timer is set to the Starting time 1 When the timer is reset the timer is set to the Ending time 37 12 0 1 Timer Alarm Control 0 disabled 1 turn off alarm when the timer reset down button is pressed default This mode is used with modes 32 24 1 32 26 1 and various code blue modes When mod...

Page 57: ...s Mode 28 4 sets the Starting seconds 8 Alternate Starting Times This mode provides up to four alternate Starting times If the Reset line is open Mode 27 1 sets the Starting hours and minutes Mode 28 1 sets the Starting seconds If the Reset line is closed to ground Mode 27 2 set the Starting hours and minutes Mode 28 2 sets the Starting seconds If the Change End line is open Mode 27 3 sets the Sta...

Page 58: ...nt Four Digits default 4 This value determines the display mode for the least significant four digits of an eight digit counter value See also Mode 37 21 37 16 0 2 Counter Auto Reset at Ending Value 0 default disabled 1 When the Ending value is reached the counter will be reset back to the starting value 2 When the Ending value is reached the counter will be reset back to the starting value plus o...

Page 59: ...8 bit default 1 Com1 SR ST 7 bit Com2 GPS 7 bit 2 Com1 SR ST 8 bit Com2 GPS 7 bit 3 Com1 SR ST 7 bit Com2 GPS 8 bit 37 24 1 24 Alarm Schedule Time Zone Source 1 default This mode determines which time zone will be used for alarm schedules 37 25 0 1 Display Colon on Date Display Mode 53 0 disable default 1 enable 37 28 0 1 Enable Disable Analog Time Zone Master Clock 0 Disabled default 1 Enabled Th...

Page 60: ...remain active For example a display could have three displays See also Mode 32 55 Mode 32 42 and Mode 32 49 6 Addressable Clock Function with Active Up and Down buttons whether or not the clock as actively selected This mode is the same as Mode 37 29 5 except the Up and Down buttons remain active all the time whether the clock is actively selected or not See also Mode 32 55 Mode 32 42 and Mode 32 ...

Page 61: ...ommended when the high precision oscillator is installed HX option See also Mode 4 37 38 0 1 Timer Precision Control 0 disabled default 1 enabled This mode improves timer precision when displaying fractions of a second but changes the real time seconds each time timer is started or stopped USE ONLY WITH SHORT DURATION TIMERS If real time accuracy is a priority then disable this mode If timer preci...

Page 62: ...nds while the date only displays for 2 seconds This reduces confusion when numbered displays are alternating back and forth Mode 37 13 acts as a multiplier for Modes 37 41 37 42 and 37 43 For example if 37 13 10 then setting Mode 37 41 99 would cause a 99 second delay 37 43 0 99 tenths of a second Third Alternating Display Duration Third in Sequence to Display This delay value allows easier viewin...

Page 63: ... Digits to Display Timer Days or Hours 0 disabled default 1 Use alpha special counter characters to display timer days 2 Use alpha special counter characters to display timer hours 3 Display seconds derived from hrs min sec 4 Display Start Count using the Alpha Counter Mode 5 Display End count using the Alpha Counter Mode The digital lettering may be used to display elapsed days or hours by using ...

Page 64: ...ndependently Assigning each school their own group number will accomplish allow them to operate data radios without interference between the two systems Changing this parameter will cause the clock to perform a system reboot 37 77 0 59 Standard MegaTiger Clock Time Reception Control 0 default receive time updates from all devices 1 receive only standard time updates on the GPS port 7 receive only ...

Page 65: ... zones as Mode 37 78 Mode 37 78 default 0 enables time zone support and determines the number of zones in the display Mode 32 12 1 See also Mode 37 77 to limit reception from other time sources Slave Clock Configuration Mode 37 78 default 0 enables time zone support and determines the zone number of the master clock to display on the respective digital clock Mode 32 12 0 37 79 1 2 3 Infrared Remot...

Page 66: ... button to back up and set the new volume setting Press the Timer Control button to save and exit the menu without changing the volume The new volume setting will be used the next time the clock is power cycled If the alarm relay is continuously activated the MP3 player will not operate Try changing Mode 37 32 1 default 37 85 1 99 Alarm MP3 Audio Player Audio File to Play 1 99 audio file number 47...

Page 67: ... 0 SRST port default 1 GPS port The mode select the serial channel to use for the serial MP3 alarm audio player 39 0 9999 Panic Alarm Timeout Value See Mode 45 19 This mode was moved to Mode 45 19 on 2 14 05 Tiger Version 3 41 0 default This value is used in conjunction with Mode 37 2 Alarm Panic Button When timeout seconds are greater than zero the panic alarm will turnoff when the timeout time i...

Page 68: ...n with modes 9 and 10 Ending hours minutes and seconds See also Mode 32 18 to enable long duration timer mode While in long duration timer mode pressing the timer control button will temporarily switch to real time operation At this point you can change the time and by pressing the mode button you enter the menu system to change the real time month day and year Pressing the timer control button ag...

Page 69: ... therefore the port address is 16000 Select mode 70 4 to send the stored value to the Ethernet interface See also Modes 45 10 45 11 70 and 71 45 13 0 9999 Alarm Frequency 0 disabled 1 9999 seconds between alarms This mode is used with the Alarm Toggle Mode 49 During the period the alarm is normally toggled on the alarm can be turned on and off at a periodic rate Mode 45 13 determines how often the...

Page 70: ...ified by Mode 45 18 For example if Mode 45 18 500 then NMEA time received will be advanced by 2 500 seconds 45 19 0 9999 Panic Alarm Timeout Value formerly Mode 39 0 default This value is used in conjunction with Mode 37 2 Alarm Panic Button When timeout seconds are greater than zero the panic alarm will turnoff when the timeout time is reached This mode was previously assigned to Mode 39 but was ...

Page 71: ...nd Mode 45 23 45 23 111 3231 Custom Daylight Saving Rule Ending Value for Mode 24 n 11 Default 0 Values for rule driven custom daylight saving time for Mode 24 n 11 The format is MMRD where MM month 1 12 R instance of the select day of the week 1 5 5 last instance D day of the week 1 7 where 1 Monday and 7 Sunday For example 357 represents the last Sunday in March or 1117 represents the First Sund...

Page 72: ...th For example March 15th 2315 April 1st 2401 The day of the year derived from this rule is stored in Mode 52 6 If the DST date is a fixed day i e 15th of the month then set this mode to 0 and enter the Julian day into Mode 52 6 instead See Mode 24 n 20 and Mode 45 30 45 32 111 3231 Custom Daylight Saving Rule Starting Value for Mode 24 n 21 ver 4 64 Default 0 Values for rule driven custom dayligh...

Page 73: ...he select day of the week 1 5 5 last instance D day of the week 1 7 where 1 Monday and 7 Sunday For example 357 represents the last Sunday in March or 1117 represents the First Sunday in November If the value 2000 then the right two digits represent the day of the month The left two digits minus 20 equal the month For example March 15th 2315 April 1st 2401 The day of the year derived from this rul...

Page 74: ...ed in Mode 52 13 If the DST date is a fixed day i e 15th of the month then set this mode to 0 and enter the Julian day into Mode 52 13 instead See Mode 24 n 23 and Mode 45 398 45 39 111 3231 Custom Daylight Saving Rule Ending Value for Mode 24 n 24 ver 4 64 Default 0 Values for rule driven custom daylight saving time for Mode 24 n 24 The format is MMRD where MM month 1 12 R instance of the select ...

Page 75: ...5 alpha characters This mode is used to edit the digital alpha characters These characters are used for zone titles on time zone displays and general message displays You can enter a message up to 255 characters regardless of the number of alpha digits installed If the message length exceeds the number of digits installed the message can be displayed by rotating the message into view one section a...

Page 76: ...ping Code A Z no I or O 25 Temp F hundred 26 Temp F ten 27 Temp F unit 28 Temp C hundred 29 Temp C ten 30 Temp C unit 31 Julian date or day of the year Unit see also 1 and 2 128 Counter hundred millions digit 129 Counter ten millions digit 130 Counter millions digit 131 Counter one hundred thousands digit 132 Counter ten thousands digit 133 Counter thousands digit 134 Counter hundreds digit 135 Co...

Page 77: ...racter eight English Only see also 9 11 160 Day of the Week alpha character nine English Only see also 9 11 161 Day of the Week alpha character one Spanish Only 162 Day of the Week alpha character two Spanish Only 163 Day of the Week alpha character three Spanish Only 164 Month alpha character one Spanish Only 165 Month alpha character two Spanish Only 166 Month alpha character three Spanish Only ...

Page 78: ...wo fixed messages depending upon the condition of the warning lights Set Modes 43 1 4 32 26 2 See also Modes 43 2 43 3 52 1 and 51 2 4 alternate between two alpha messages depending on yellow warning light status This mode is used to switch between two fixed messages depending upon the condition of the warning lights See also Modes 43 1 4 32 26 2 43 2 43 3 52 1 and 51 2 5 alternate between two alp...

Page 79: ...de 3 The value selected will be subtracted from either the master intensity or the auto brightness level 37 14 21 35 Increase the master intensity Mode 3 The value selected less 20 will be added to either the master intensity or the auto brightness level 37 14 16 Blink alpha characters once per second to indicate sync GPS IRIG B and Ethernet reception If no sync source is used setting Mode 32 2 4 ...

Page 80: ...the year to switch from daylight time to standard time This value is used by Mode 24 code 11 Both modes 52 3 and 52 4 must be set to the desired day of the year See also Mode 45 23 to define new daylight saving rule Mode 45 23 must be set to 0 to enable this mode otherwise use Mode 45 23 to enable rule base switching 52 5 1 365 Custom Julian Daylight Time Switch User Defined 20 Enter the day of th...

Page 81: ...be set to the desired day of the year See also Mode 45 37 to define new daylight saving rule Mode 45 37 must be set to 0 to enable this mode otherwise use Mode 45 37 to enable rule base switching 52 13 1 365 Custom Julian Daylight Time Switch User Defined 24 Enter the day of the year to switch from standard time to daylight time This value is used by Mode 24 code 24 Both modes 52 13 and 52 14 must...

Page 82: ...ending year of an alarm date range If the Year in Mode 55 equals 2000 then the alarm will activate every year with the month day range specified The ending date must be occur after the beginning date See also Mode 38 to force an alarm schedule active Alarm group 1 is different than the other 19 alarm groups If no date range is active then group is 1 the default This feature reduces the number of a...

Page 83: ...he offset may extend into the ten millionths When entering negative numbers a minus sign will appear until four digits are used If Mode 63 is negative then Modes 62 and 64 must also be negative At that time a light will appear in the upper left corner of the display to indicate the value is negative See also Modes 62 and 63 See also Mode 72 to enable disable Sidereal Time Sidereal Time Example 97 ...

Page 84: ...grees To enter an offset to UTC enter a negative number for fractional decimal degrees West and a positive number for fractional decimal degrees East The fractional portion of the offset may extend into the ten thousandths When entering negative numbers a minus sign will appear until four digits are used If Mode 63 is negative then Modes 62 and 64 must also be negative At that time a light will ap...

Page 85: ...ffset has been entered For 6 digit clocks that display hours minutes and seconds be sure to configure two zones One zone for hours and minutes and the other zone for seconds Configure both zones using Modes 62 63 and 64 Set mode 72 1 1 and Mode 72 2 1 to enable both zones See also Modes 62 63 and 64 74 1 99 0 255 CEL FH SS Radio NV Ram Parameter Mode 74 n y n NV mode y value change any NV ram Mode...