background image

Braun Corporation FMVSS No. 403 Quick Reference Installation Sheet 32494

1

Position Lift 

90

Vertical Arm

must clear

door opening.

Vertical Arm

must clear

door opening.

Center

 lift in 

door opening.

Side

 to 

Side

Alignment

Align

(Parallel)

Align

(Parallel)

Lift towers and 

vertical arms 

must

be parallel (aligned) 

with vertical sides 

of door jamb and 

perpendicular (90˚) 

to the vehicle floor.

Figure B

Installation Kit 

30955K

supplied

in lift parts box.

Detailed instructions 

supplied in kits.

Figure C

Edge of Finished Floor or Stepwell Filler

(not outboard edge of vehicle)

Inboard Edge of Threshold Warning (Top) Plate

(with plate folded down)

Minimum per

FMVSS No. 403

18"

18"

Vehicle

Side Door Rear Door Rear Door

Ford

30956K

30957K

30970K-42

GM/Chevy

30958K

Extended

Length

Chassis

Standard Length Chassis

Installation Kits

*30959K

*30981K

* Rear Bumper 

Replacement Kit 

19395A96 required.

“DOT — Private Use Lift”

NHTSA Vehicle Physical Requirements

B

A

C

Figure A

Door Opening Dimensions

Vehicle lift access door opening 

must meet specified dimensions.

Braun Corporation FMVSS No. 403

Quick Reference Installation Sheet 32494

OEM (Van) Chassis 

Floor Requirements

Nonmodified OEM full 

size floors meet all 

requirements.

Alternative floor 

structures are allowed 

providing the installed lift 

system passes all FM-

VSS 403 requirements.

“DOT - Private Use Lift” verifies this 

platform lift meets only the “private use lift” 

requirements of FMVSS No. 403.  This lift 

may be installed on all vehicles appropriate 

for the size and weight of the lift, except for 

buses, school buses, and multi-purpose 

passenger vehicles other than motor homes 

with a gross vehicle weight rating (GVWR) 

that exceeds 4,536 kg (10,000 lb).

Clear Door Opening Width

Maximum Floor-to-Ground

A
B
C

47"

40"

42"

Minimum Clear Door 

Opening Height

NVL955IB3144

Summary of Contents for FMVSS No. 403

Page 1: ...s Installation Kits 30959K 30981K Rear Bumper Replacement Kit 19395A96 required DOT Private Use Lift NHTSA Vehicle Physical Requirements B A C Figure A Door Opening Dimensions Vehicle lift access door...

Page 2: ...ssis 1 Drill 1 1 8 diameter grommet access hole Check under the vehicle for obstructions 2 Insert grommet Secure grommet with two self tap screws 3 Route ground and power cables through grommet Route...

Page 3: ...Install 31798A in cavity 7 or 9 Shipped As VEHICLE SECURE SIGNAL Grey Red LIFT STOWED SIGNAL Yellow Light Blue PUMP MODULE CONNECTOR J21 6 5 4 3 2 1 SIGNAL DEFINITION NO 9 COND WIRE CODE 7 VEHICLE SE...

Page 4: ...tform at desired oor level position passenger loading unloading height Note Position platform such that a the inner roll stop is laying at on the threshold plate b platforrm has not begun to fold 2 Tu...

Page 5: ...2 Press red DOWN switch until the entire platform reaches ground level stops and outer barrier unfolds fully see Photos H and I Release switch Switch Arm Switch Slide knob in to DOWN position See Pho...

Page 6: ...r Platform and Unfold Outer Barrier Place slotted end of pump handle onto back up pump release valve and turn counterclockwise open 1 2 turn only until the platform reaches ground level and or outer b...

Page 7: ...nents Platform compo nents exposed to contaminants when lowered to the ground may require extra attention Lift components requiring grease are lubricated dur ing assembly procedures When these compone...

Page 8: ...ting pivot slide arm UHMW slide bear ings buttons Inspect vertical arm plastic covers Inspect power cable Mounting Decals and Antiskid Maintenance and Lubrication Schedule Perform all procedures liste...

Reviews: