background image

1

  Owner’s Manual

Food Processor Plus

models:

MCM 5000 UC • MCM 5100 UC

MCM 5200 UC

READ THIS MANUAL

thoroughly for important safety and operating

instructions before using this appliance.

Summary of Contents for MCM 5000 UC

Page 1: ...1 Owner s Manual Food Processor Plus models MCM 5000 UC MCM 5100 UC MCM 5200 UC READ THIS MANUAL thoroughly for important safety and operating instructions before using this appliance ...

Page 2: ...r utensils away from whisks blades disc dough hook and or other moving parts during operation to reduce the risk of injury to persons and or damage to the appliance or its attachments 9 Do not operate any appliance with a damaged cord or plug or after the appliance malfunctions or is dropped or damaged in any manner Return appliance to the nearest authorized service facility for examination repair...

Page 3: ...How to use dough hook 12 How to use whipping whisk 12 13 How to use slicing and grating discs 14 Care and cleaning of bowl and its accessories 16 Blender with unbreakable plastic jar 16 How to use blender 17 Placing blender into operation 18 Example of use of blender 18 Care and cleaning of blender 19 Citrus Juicer 19 Placing into operation with citrus juicer 20 Care and cleaning of mixing bowl wi...

Page 4: ...he MCM 5200 UC comprised of a four speed electronic power unit with automatic cord rewind three quart capacity mixing bowl cover with integral feeding tube and pusher measuring cup multifunction blade whipping whisk dough hook reversible slicing disc reversible coarse grating disc fine grating disc 6 cup capacity blender citrus juicer juice extractor motor drive cover and spatula Unpacking Careful...

Page 5: ...5 MCM 5000 UC MCM 5200 UC MCM 5100 UC Figure 1 ...

Page 6: ...Fadden Avenue Huntington Beach CA 92649 or call us at 1 866 44BOSCH 1 866 442 6724 Power Unit Features The MCM 5000 power units have the following features refer to figure 2 530 watt motor One of the most powerful motors offered with any food processor system Electronic speed control Six position rotary switch on the MCM 5200 see figure 2a four position rotary switch on the MCM 5100 and MCM 5000 f...

Page 7: ... coupled to the motor used to drive the blender and other special accessories located under the Safety Motor Drive Cover figure 2e A dual drive figure 2f used by bowl accessories one high torque drive used to drive dough hook citrus juicer and other special accessories requiring high torque and a high speed drive used to drive the multifunction blade beater whipping whisk and other accessories req...

Page 8: ...t to be used Select the attachment you wish to use 4 Cover the drive not being used If dual drive is to be used for selected attachment make sure that safety motor drive cover is placed over the high speed blender drive and pressed down until it snaps in place If high speed blender drive is to be used remove the safety motor drive cover from the high speed blender drive and place mixing bowl over ...

Page 9: ...for the specific attachment being used 9 Continue use If the attachment was of the batch feed type and you wish to continue using the attachment empty the bowl or jar of the attachment per its specific instructions and reinstall the attachment as before Repeat steps 5 through 8 as often as necessary to complete work 10 Work completed remove attachment If the attachment is of the continuous feed ty...

Page 10: ...ed blender drive Place the mixing bowl on the dual drive of the power unit as shown in figure 4a and turn the bowl clockwise with a slight downward pressure until bowl is firmly seated Attachments The attachment s that have been used should be disassembled and washed dried and stored for future use It is recommended that after cleaning the mixing bowl and its cover be stored on the food processor ...

Page 11: ...n cover and then turn cover clockwise until tab on cover enters cover interlock and turn until tab clicks into place figure 6b Figure 6 The cover should be in place whenever the power unit is in operation The cover serves to prevent accidental contact with the moving blade Also the power unit will not operate unless the tab on the cover is in place and has engaged the safety cover interlock Placin...

Page 12: ...bowl cover on the bowl Make sure arrows on cover and bowl are aligned so that tabs on bowl fit into channels in cover and then turn cover clockwise until tab on cover enters cover interlock and turn until tab clicks into place The cover should be in place whenever the power unit is in operation The cover serves to prevent the escape of flour dust at the beginning of the stirring and kneading proce...

Page 13: ... dual drive of the power unit as shown in figure 4a and turn the bowl clockwise with a slight downward pressure until bowl is firmly seated 3 Engage the whipping whisk on the dual drive of the power unit by placing it over the center column as shown in figure 8 Once in place check to make sure the whipping whisk has engaged the dual drive by turning the whipping whisk counterclockwise while pushin...

Page 14: ...rating disc as shown in figure 5g The slicing disc and the grating discs are intended to be used for slicing and or grating of vegetables as well slicing grating of soft cheeses and sausages or meat and grating of vegetables and hard cheese WARNING 1 Blades on discs are sharp Handle carefully Always use the center plastic holder to lift or handle discs Do not grip the discs by the blades or metal ...

Page 15: ...O Off and unplugged 2 The top cover should be removed and the items causing the blockage removed WARNING The blades on the discs are very sharp Handle with care Use center plastic holder when handling discs 4 Next place the mixing bowl cover on the bowl Make sure arrows on cover and bowl are aligned so that tabs on bowl fit into channels in cover and then turn cover clockwise until tab on cover en...

Page 16: ...ver be stored on the food processor In this way if you wish to at some later time to use the blender the mixing bowl and its cover will already be in place Note The mixing bowl and its cover must be in place with the top cover rotated clockwise so that tab on cover engages the cover interlock before the blender can be used See below Blender with Unbreakable Plastic Jar The MCM 5100 UC and MCM 5200...

Page 17: ...ck and turn until tab clicks into place figure 4b 4 Place the blender jar blade assembly on the high speed blender drive of the power unit and turn clockwise to lock in place see figure 10a Then place cover with cover closure funnel on blender jar and turn clockwise to lock in place figure 10b Figure 10 Placing Blender into Operation Make sure that the power unit is on a smooth clean suitable work...

Page 18: ... bearing lubricant of the blade base assembly Do not use scouring cleaners on any of the blender parts With the power unit turned Off and unplugged it should be cleaned only with a clean damp cloth Then wipe off the safety motor drive cover and reinstall on the power unit if necessary Never use coarse or caustic cleaning products to clean the power unit Never immerse the power unit in water the cl...

Page 19: ...blender drive Place the mixing bowl on the dual drive of the power unit as shown in figure 4a and turn the bowl clockwise with a slight downward pressure until bowl is firmly seated 3 Place the citrus juicer on the dual drive of the power unit by placing it over the center column and turning it clockwise as shown in figure 13 until tab on cover enters cover interlock and turn until tab on the rim ...

Page 20: ...uits vegetables such as carrots and tomatoes Use of mixing bowl with juice extractor Before beginning to attach this or any other attachment make sure that the power unit is on a smooth clean suitable work surface and switched to the Off position O Off and that you have the safety motor drive cover in place of the high speed blender drive 1 Before using the mixing bowl and juice extractor for the ...

Page 21: ...Removing Contents below Removing Contents Before beginning to remove the contents from the bowl or pulp from the strainer make sure that the power unit has been turned to the Off position O Off Remove the cover of the juice extractor from the bowl by turning the cover counterclockwise while lifting Then remove the grater strainer Empty pulp from the strainer as required If bowl needs to be emptied...

Page 22: ...ection and trying its remedies you are still having a problem please do contact us by either writing to us at Bosch Small Appliances Customer Support BSH Home Appliances 5551 McFadden Avenue Huntington Beach CA 92649 or e mailing us at boschsmallappliances bshg com or calling us at 1 866 44BOSCH 1 866 442 6724 If you do write to us please include your e mail address or a daytime telephone number w...

Page 23: ...at caused the safety to trip ContactBoschSmallAppliances Customer Support see page 22 for closest Bosch authorized service center Take or ship the food processor to a Bosch authorized service center to have the safety cutout replaced Rotary switch 1 Safety cover interlock is not Safety cover interlock must be will not turn engaged engaged before rotary switch can be turned Rotate bowl cover or jui...

Page 24: ... Process on speed 1 or 2 until smooth Add pinenuts and blend thoroughly Toss with cooked pasta or spread on bread or crackers Fruit Smoothies 2 cups fruit juice 2 cups frozen fruit 1 2 can frozen juice concentrate 1 cup fruit flavored yogurt 1 2 cups of ice 1 fresh banana Place all ingredients in Bosch blender and mix until smooth on highest speed Experiment with different flavor combinations such...

Page 25: ...on speed 1 or 2 Add flour baking soda and salt Blend well stir in rolled oats and chocolate chips by hand Drop by spoonfuls onto greased baking sheets Bake in a 350 F oven for 8 10 minutes Cool before removing from pan Makes 5 dozen Acknowledgments The sample recipes listed above were sub mitted by Salsa Caroline Ciarelli BSH Home Appliances Pesto Kitchen Resource Fruit Smoothies Marni Rader BSH A...

Page 26: ...26 Important Notes Important Notes Important Notes Important Notes Important Notes ...

Page 27: ...this warranty are failures caused by accident misuse neglect abuse including tampering use of frequency or voltage other than marked on the product and use for commercial purposes To the extent allowed by law this warranty sets out your exclusive remedies whether for negligence or otherwise BOSCH will not be liable for any consequential or incidental damages losses or expenses THIS WARRANTY IS IN ...

Page 28: ...28 Looking for more information about BOSCH products Visit our Web site www boschsmallappliances com ...

Reviews: