Overview 

The ISW-EN1262 is a low-current motion detector that is highly 
sensitive to moving heat (infrared radiation) sources.  

Use the ISW-EN1262 in residential and low-traffic commercial 
applications. 

1.0

 

Open the Detector Housing 

1.

 

Insert a small flat-blade screwdriver at a 45

°

 angle into the tab 

on the bottom of the unit.  

2.

 

Press downward on the handle of the screwdriver until the 
latch holding the cover to the housing base releases. 
Refer to 

Figure 1

 

Figure 1: Open the Housing 

 

 

Figure 2: Detector Components 

1

2

3

4

6

7

5

NZ 

 

1 - 

 

Wall Tamper pins 

2 - 

 

Battery 

3 - 

 

Circuit Board Attachment latch 

4 - 

 

Housing Tamper switch 

5 - 

 

Look-down lens 

6 - 

 

Reset button 

7 - 

 

Frequency Band pins 

 

2.0

 

Mount the Housing Back Plate 

1.

 

Pull the circuit board attachment latch and lift the circuit board 
out of the housing. 
Refer to 

Figure 2

2.

 

Use a 3/16 in. (4.8mm) bit to drill out the tamper rivet hole 
index. Refer to 

Figure 3

 on page 1. 

3.

 

Install the tamper wall anchor. 

 

Figure 3: Mounting Holes 

1

2

3

2

2

3

2

 

1 - 

 

Taper rivet hole 

2 - 

 

Corner- mount hole 

3 - 

 

Wall mount hole 

 

4.

 

Mount the housing using either the three wall-mount holes or 
the four corner-mount holes. 

Use a 4 mm (5/32 in.) bit to drill the appropriate housing 
holes. 

Use the included screws to mount the housing. 

 

If using the wall tamper:  

-

 

Ensure that the wall tamper rivet depresses the 
wall tamper switch. Refer to 

Figure 4.

 

-

 

Remove the jumper plug from the wall tamper 
selection pins. Refer to 

Figure 2

, page 1. 

 

Figure 4: Wall Tamper Switch 

1

2

 

1 - 

 

Wall tamper rivet 

2 - 

 

Wall tamper switch arm 

 

 

Reviews: