background image

FPBE W2 Fingerprint Reader

ARD-FPBEW2-IC

en

Installation Guide

Summary of Contents for ARD-FPBEW2-IC

Page 1: ...FPBE W2 Fingerprint Reader ARD FPBEW2 IC en Installation Guide ...

Page 2: ......

Page 3: ...mes and function of parts 8 2 3 Cables and Connectors 10 2 4 How to enroll a fingerprint 13 3 Installation 16 3 1 Fixing the bracket and the product 16 3 2 Power supply connection 20 3 3 Network connection TCP IP 21 3 4 Wiegand Connection 22 3 5 RS 485 Connection 23 3 6 Resetting Network Settings 24 4 Technical Data 25 4 1 Product Specifications 25 4 2 Dimensions 28 ...

Page 4: ...tric heater Install the product in a dry place Install the product in a place with no electromagnetic interference Do not install or repair the product independently Do not allow liquids such as water beverages or chemicals get into the product Warning Risk of explosion Replacing the RTC battery with an incorrect type of battery may cause explosion Discard the battery according to the appropriate ...

Page 5: ...etely exposed install the product together with the enclosure When installing a number of devices allow a space between the devices for installation Do not drop the product or apply an impact to the product Do not to contaminate or damage the fingerprint contact unit with a dirty hand or foreign substances When cleaning the product wipe the product with a soft and dry cloth and no water benzene or...

Page 6: ...uction FPBE W2 Fingerprint Reader 2018 02 ARD FPBEW2 IC Bosch Access Systems GmbH 2 Introduction 2 1 Components ARD FPBEW2 Bracket Ferrite Core 1 EA PVC anchor 2 EA Heat shrink Star shaped wrench Fixing screw 2 EA ...

Page 7: ...nt Reader Introduction en 7 Bosch Access Systems GmbH 2018 02 ARD FPBEW2 IC Drilling template OSS Manual Safety Instructions Quick Installation Guide Notice Components may vary according to the installation environment ...

Page 8: ...2 2 Names and function of parts Item Feature 1 LED lamp Indicates the operational status of the product with the color of the LED lamp 2 RF card authentication unit Reads RF cards for entering and exiting 3 Fingerprint authentication unit Reads fingerprints placed on it for entering and exiting ...

Page 9: ...GmbH 2018 02 ARD FPBEW2 IC Item Feature 4 Network reset button Resets the network configuration For details refer to the Resetting Network Setting 5 LED lamp for Network Shows the status of the network connection 6 Cable Interface cable Power cable Ethernet connector ...

Page 10: ...10 en Introduction FPBE W2 Fingerprint Reader 2018 02 ARD FPBEW2 IC Bosch Access Systems GmbH 2 3 Cables and Connectors ...

Page 11: ...M Green White stripe 3 WG Tamper NC Orange White stripe 4 Not used Blue Brown 5 Not used Red Green 6 WG D0 Green 7 WG D1 White 8 WG GND Black 9 TTL IN1 LED red Brown 10 TTL IN0 LED green Purple 11 PWR VDC Red 12 Not used Pink 13 PWR GND Black White stripe 14 485 TRXN RxTx Yellow Black stripe 15 485 TRXP RxTx Blue White stripe 16 485 PAG White Black stripe ...

Page 12: ...12 en Introduction FPBE W2 Fingerprint Reader 2018 02 ARD FPBEW2 IC Bosch Access Systems GmbH 17 ENET TXP White 18 ENET TXN Orange 19 ENET RXP Black 20 ENET RXN Yellow ...

Page 13: ...on to the following matters the authentication rate can be improved Selecting a finger for fingerprint input In preparation for the case that the fingerprint of a specific finger cannot be used for example if the user is lifting a load with one hand or a finger gets hurt up to 10 fingerprints for each user can be registered In the case of a user whose fingerprint cannot be recognized well the auth...

Page 14: ...rint of a finger to be registered twice Cautions for enrolling a fingerprint When a fingerprint is recognized it is compared with the initially registered fingerprint so the initial fingerprint enroll is the most important Pay attention to the following matters when enrolling the fingerprint 1 Place the finger deep enough to contact with the sensor completely 2 Place the center of the fingerprint ...

Page 15: ...ut method If the fingerprint authentication cannot be done smoothly it is recommended to take the following measures 1 If the finger is smeared with water or sweat dry off the finger and then scan the finger 2 If the finger is too dry blow your breath on the fingertips and then scan the finger 3 If the finger has a cut register the fingerprint of another finger 4 The initially registered fingerpri...

Page 16: ...d the product Determine the correct position to install the bracket using the provided drilling template Fix the bracket firmly using fixing screws through the bracket to the position where ARD FPBEW2 will be installed Notice If installing the ARD FPBEW2 on a concrete wall drill holes insert PVC anchors and fix them with fixing screws ...

Page 17: ...FPBE W2 Fingerprint Reader Installation en 17 Bosch Access Systems GmbH 2018 02 ARD FPBEW2 IC ...

Page 18: ...18 en Installation FPBE W2 Fingerprint Reader 2018 02 ARD FPBEW2 IC Bosch Access Systems GmbH Notice To avoid RF interference a minimum separation distance must be maintained ...

Page 19: ... ARD FPBEW2 onto the fixed bracket 2 Connect the ARD FPBEW2 to the bracket by rotating the star shaped fixing screw 3 Fix the wall mount bracket on a wall using the wall mounting screws 4 Hook the FP reader on the wall mounting bracket 5 Fix FP reader on the wall mounting bracket using the star shaped screw ...

Page 20: ...ower supply adaptor of DC 12 V 10 with a minimum of 600 mA which has obtained the approval of IEC EN 60950 1 If you wish to connect and use another device to the power supply adaptor you should use an adaptor with a current capacity which is the same or larger than the total power consumption required for the terminal and another device ...

Page 21: ...P LAN connection connecting to a hub You can connect the product to a hub using a general type CAT 5 cable or higher LAN connection connecting to a PC directly The ARD FPBEW2 has an automatic MDI MDIX function so that it can be connected to a PC directly using a normal straight type CAT 5 cable or higher not a cross cable ...

Page 22: ...22 en Installation FPBE W2 Fingerprint Reader 2018 02 ARD FPBEW2 IC Bosch Access Systems GmbH 3 4 Wiegand Connection ...

Page 23: ...FPBE W2 Fingerprint Reader Installation en 23 Bosch Access Systems GmbH 2018 02 ARD FPBEW2 IC 3 5 RS 485 Connection ...

Page 24: ...rear of device until the device restart automatically 3 Connect the device with default values 3 1 TCP IP address DHCP address assignment If DHCP address assignment is failed 169 254 x x will be set 3 2 Server mode Disabled 3 3 RS 485 PC connection 115200 bps 4 Change the TCP IP address or RS 485 information 5 Turn the power off later on and then check the network setting is properly ...

Page 25: ...8 02 ARD FPBEW2 IC 4 Technical Data 4 1 Product Specifications Category Feature Specification Credential Biometric Fingerprint RF Option 125 KHz EM HID Proxy 13 56 MHz MIFARE DESFire DESFire EV1 iClass RF read range MIFARE DESFire EM HID Proxy iClass ISO15693 50 mm Felica 30 mm ...

Page 26: ...lti color Sound Multi tone Buzzer Operating temperature 20 C 50 C Storage temperature 40 C 70 C Operating humidity 0 80 non condensing Storage humidity 0 90 non condensing Dimension W x H x D 50 mm x 172 mm x 43 5 mm Bottom 38 2 mm Top Weight Device 251g Bracket 43g Including washer and bolt IP rating IP67 IK rating IK09 Certificates CE FCC KC RoHS REACH WEEE ...

Page 27: ...Extractor Matcher MINEX certified and compliant LFD Supported Interface Ethernet Supported 10 100 Mbps auto MDI MDI X RS 485 OSDP V2 Wiegand Supported PoE IEEE802 3af Tamper Supported Electrical Power Voltage DC 12 V Current Max 600 mA Wiegand output VOH More than 4 8 V Wiegand output VOL Less than 0 2 V Wiegand output Pull up resistance Internally pulled up with 1 kΩ RF read range will vary depen...

Page 28: ...28 en Technical Data FPBE W2 Fingerprint Reader 2018 02 ARD FPBEW2 IC Bosch Access Systems GmbH 4 2 Dimensions Dimensions in mm ...

Page 29: ......

Page 30: ......

Page 31: ......

Page 32: ...Bosch Access Systems GmbH Charlottenburger Allee 50 52068 Aachen Germany www boschsecurity com Bosch Access Systems GmbH 2018 ...

Reviews: