GENERAL 

S2000-IK  Revision  04  Addressable  Curtain  Passive  Infrared  (PIR)  Motion  Detector  (hereinafter  referred  to  as  the 

detector)  is  designed  to  be  used  indoors.  It  detects  intrusion  into  protected  areas  and  sends  an  alarm  message  to  the 

connected S2000-KDL controller via the two-wire multiplex addressable polling loop. 

The S2000-IK rev.04 has a two-dimensional coverage pattern (“vertical  curtain”). 

The detector provides increased immunity against lighting and radio frequency interference. 

KEY FEATURES 

  Dual-element pyro-electric infrared sensor 

  High-density coverage offering high probability of detecting an intruder 

  Protected against insects entering to the pyro-electric infrared sensors 

  Arranging sabotage-resistant zones just beneath the detector prevents unauthorized access to the detector. 

  Digital signal processing 

  Powered via the multiplex addressable polling loop of the S2000-KDL 

  Supports DPLS_v2.xx protocol 

SPECIFICATIONS 

Detection Range 

10 m 

Coverage Pattern 

Curtain (two-dimensional) 

Input Voltage (from a S2000-KDL) 

8 ÷ 10 VDC 

Current Consumption (via the loop of the S2000-KDL) 

0.5 mA max when indication is off 

Horizontal Angle of Sight 

6

°

 

Operating Temperatures 

30 to +50°C 

Humidity 

95% at 25°C, non-condensing 

Overall Dimensions (H x W x D) 

105 mm 

×

 75 mm 

×

 56 mm  max 

Weight 

0.1 kg max 

Mounting Height 

2.3 meters 

MOUNTING LOCATION CONSIDERATIONS 

The  detector  is  intended  to  be  used  indoors.  Considering  a 
location  to  mount  the  detector,  please  take  into  account  that 
the  detection  zone  must  not  be  obscured  by  any  non-
transparent  objects  such  as  curtains,  houseplants,  cabinets, 
room dividers, etc. as well as by glass or mesh partitions. 

Do  not  locate  the  detector  where  it  can  be  exposed  to  false 
alarm  sources  such  as  windows,  air  conditioners,  heaters, 
radiators, etc. 

Wires  of  the  multiplex  addressable  polling  loop  should  be 
located away from high-voltage electric cables. 

The  detector  allows  wall  or  corner  mounting  at  a  height  of 
2.3 m  above  the  floor.  This  provides  the  detection  range  at 
least 10 meters. The detection pattern is shown in Figure 1. 

 

 

Figure 1: S2000-IK Rev.04 Detection Pattern

 

Summary of Contents for S2000-IK

Page 1: ...xx protocol SPECIFICATIONS Detection Range 10 m Coverage Pattern Curtain two dimensional Input Voltage from a S2000 KDL 8 10 VDC Current Consumption via the loop of the S2000 KDL 0 5 mA max when indication is off Horizontal Angle of Sight 6 Operating Temperatures 30 to 50 C Humidity 95 at 25 C non condensing Overall Dimensions H x W x D 105 mm 75 mm 56 mm max Weight 0 1 kg max Mounting Height 2 3 ...

Page 2: ...t be assigned to a unique number 1 to 127 within the loop the address which is stored in the S2000 IK rev 04 non volatile memory EEPROM This address provides identifying the detector by the S2000 KDL controller Moreover the monitoring strategy must be defined which will be used by the S2000 KDL controller while processing signals received from the S2000 IK rev 04 Programming the S2000 IK Rev 04 Ad...

Page 3: ...on zone The detector shall issue an alarm after your three or four steps with its LED being flashing Wait until the LED finishes flashing and then continue crossing the detection zone The detector should issue an alarm If nobody is moving within the detection zone no alarms shall be issued WARNING To ensure proper operation walk test the S2000 IK rev 04 annually as described above ENABLING DISABLI...

Page 4: ...tability must be brought within 12 months from date of original purchase In no case shall seller be liable to anyone for any consequential or incidental damages for breach of this or any other warranty express or implied or upon any other basis of liability whatsoever even if the loss or damage is caused by the seller s own negligence or fault Some countries do not allow limitation on how long an ...

Reviews: