manualshive.com logo in svg
background image

11

9

0120

March 2017 (6)

Body Clock Health Care Ltd

108 George Lane, South Woodford

London E18 1AD

Tel (+44) (0)20 8532 9595

Fax (+44) (0)20 8532 9551

www.bodyclock.co.uk

e-mail [email protected]

This manual is recyclable

Se

ns

aT

ON

E

In

str

uc

tio

ns

 fo

r u

se

Using Your SensaTONE

For PFS

PFS - Pelvic Floor Stimulation

a) Switch the unit on by pressing

the Power Key button. The

SensaTONE will always start up

in Mode A.

b) The SensaTONE has four

preset programmes: 

Mode A

- Urge Incontinence

Mode B

- Stress Incontinence

Mode C

- Mixed Incontinence

Mode D

- After Care

c) Select the mode most

appropriate for your type of

incontinence by pressing the

‘MODE’ key. Please refer to

page 9 if you are unsure of

which mode to use.

d) Now begin by pressing the

‘Intensity Up’ key. Each time

you press this key, you will see

the intensity level increase on

the LCD.

e) Carefully continue to press

‘Intensity Up’ key until you

comfortably feel your muscles

contracting. If the sensation

feels too strong, simply press

the ‘Intensity Down’ key

minimise the feeling.

f ) Modes A, B and C all have fixed

programme times. The

SensaTONE will automatically

switch off once the programme

is complete. Mode D does not

have a fixed programme time.

Refer to page 9 for more

information about Mode D.

g) After use, always remember to

ensure that the SensaTONE is

switched off. Then remove the

SensaTONE probe from your

body, disconnect the leads and

then clean it in accordance with

the instructions found on page

6 or in the SensaTONE probe

instruction manual.

8

Choosing The Right

PFS Mode

There are three types of

incontinence, all of which can be

treated with the SensaTONE:

1.

Urge incontinence (MODE A)

-

occurs with a strong, sudden

and uncontrollable urge to

urinate.

2.

Stress incontinence (MODE B)

-

occurs when sneezing,

coughing, laughing, lifting or

during exercise and causes a

small amount of urine to leak.

3. 

Mixed incontinence (MODE C)

- a combination of urge and

stress incontinence.

Frequency Of Use

Below is a guide showing how

often to use each PFS mode on

your SensaTONE. If your muscles

start to ache, or you have any

problems using the SensaTONE,

please contact your medical

adviser.

Using Mode D – After Care

This is an optional mode and can

be used as follows:

Directly after treatment with the

SensaTONE, provided you are not

experiencing any muscle fatigue.

As a maintenance mode after

you have been using the

sensatone on a regular basis

and have experienced an

improvement in your condition.

Please note that there is no

recommended treatment time for

this mode. It is at your discretion.

It is suggested that it is used no

more than between 15-30 minutes

per day.

PFS - Frequently Asked

Questions

Q

How long will it take to see

results?

A  The amount of time varies

from woman to woman; it is

also dependent on the type of

incontinence from which you

are suffering.

STRESS Incontinence

-

improvement comes

slowly with the building

of muscle fibre and

nerve sensitivity. This can

take up to 2 months.

URGE Incontinence

-

improvements are made by

reducing the false signals

sent by the bladder to the

brain. Results can be seen in

as little as 14 days.

MIXED Incontinence

-

improvements are made

by building the muscle fibre

and nerve sensitivity as well

as reducing the false signals

being sent to the brain. This

can take slightly longer, but

you should be able to notice 

a difference within 21 days.

Q

What does it feel like?

A  All three PFS programmes feel

slightly different. In general,

the feeling is that of a

pleasant, tingly, squeezing

sensation that contracts and

relaxes the pelvic floor

muscles.

Q

Is it suitable for use by all

women?

A

Yes, all women can use it

provided none of the

contraindications apply.

Q

Can I use it whilst I’m

pregnant?

A

No, not until 12 weeks after

the birth.

Q

Are there any side effects?

A

No, it is totally drug free. There

are no known side effects.

Before first use of the
SensaTONE, please
familiarise yourself
with the ‘Precautions
and Contraindications’
contained on page 4.

The SensaTONE should

NOT

be used:

• During pregnancy.
• During the menstrual period.
•  If you suffer a urinary or

vaginal infection.

•  At the same time as a barrier

contraceptive device such as
a diaphragm or cervical cap.

• Until 12 weeks after childbirth.

Programme

Mode A

Mode B

Mode C

Mode D

Length

30 mins

30 mins

45 mins

How often

1-2 times a day

Complete the programme once a day

Once a day or every other day depending on severity

Please see ‘Using Mode D’ above

DO NOT EXCEED TREATMENT TIMES UNLESS ADVISED BY A MEDICAL PROFESSIONAL.

If you have any further

questions on

incontinence or need

some advice, contact

The Bladder and Bowel

Foundation on:

Helpline: (+44) (0)845 345 0165

e-mail:

[email protected]

web:

www.bladderandbowelfoundation.org

Reg Charity

1085095

10

Programme

Display

Output Frequency/Duration

5Hz / 3 mins  10Hz / 5 mins  15Hz / 5 mins

20Hz / 5 mins  15Hz / 5 mins  

10Hz / 5 mins  5Hz / 2mins

Total time = 30 mins

Urge

A

10Hz / 5 mins  35Hz / 5 mins  50Hz / 10mins

35Hz / 5mins  10Hz / 5mins

Total time = 30 mins

Stress

B

10Hz / 5mins  20Hz / 5 mins  30Hz / 5 mins

40Hz / 5mins  50Hz / 5mins  40Hz / 5mins

30Hz / 5mins  20Hz / 5mins  10Hz / 5mins

Total time = 45 mins

Mixed

C

Frequency Modulation

Frequency increases from 2 Hz to 10 Hz in 4 secs. 

and then back to 2Hz in another 4 secs. 

Total cycle = 8 secs 

Total time = 45 mins

After Care

D

All outputs have 200µs pulse width. For the Urge, Stress and Mixed mode,

the output pulses are alternatively switched on and off for 5 seconds.

Specifications

Output Channel

Single Channel

Output Waveform

Bi-phasic rectangular

Output Voltage

0-40V adjustable in 14 steps across a 500 ohm load

Output Intensity

0-80mA adjustable in 14 steps across a 500 ohm load

Automatic Power Off

5 minutes

Battery

2 x 1.5v AAA Batteries

Battery Low Detect

2.2V±0.1V

Guarantee

Your SensaTONE machine is guaranteed for a period of 2 years

against manufacturer’s defects. Please record purchase details

in  the  space  provided  below  for  your  record  purposes.  The

guarantee does not include leads, electrodes, probes or battery.

Date of purchase:

Invoice number:

Отзывы: