Technical Data

MATERIALS:

Cabinet — 

18-8, type-304, heavy-gauge stainless steel. All-welded construction. Exposed surfaces have satin finish. The activation sensor mounts on a 

hinged, locking panel.

Doors — 

18-8, type-304, 1.2mm (18-gauge) stainless steel. 14mm (9/16") 90° return for maximum rigidity. Secured to cabinet with a concealed, full-

length stainless steel piano-hinge. Equipped with a stainless steel cable door-swing limiter and two tumbler locks per door keyed like other Bobrick 

washroom accessories.

Paper Towel Dispenser — 

18-8, type-304, 0.8mm (22-gauge) stainless steel. Equipped with 90° return towel guide angle to prevent paper towels from 

falling forward out when door is opened for servicing. Rounded towel tray has hemmed opening to dispense paper towel without tearing. Capacity: 600 

multifold or 450 C-fold paper towels.

TowelMate™ Towel Rod Assembly — 

Consisting of a round Nylon Rod and (2) stainless steel Rod Screws for attachment, is field replaceable. 

Stainless steel Stop Screws (2) lock TowelMate Towel Rod assembly in place.

Waste Bin — 

Leak-proof rigid molded plastic. Removable for servicing. Capacity: 13.7 liters (3.6 gal.).

Dryer:
Cover — 

18-8, type-304, 0.8mm (22-gauge) stainless steel. Cover is secured to mounting base with two pan-head stainless steel screws.

Mounting Base —

 1.5mm (20-gauge) plated steel with three 6mm (0.236") diameter mounting holes.

Motor — 

Universal, 1/7 hp, 8000 rpm, on resilient mounting. Sealed ball bearing at drive-shaft end and self-lubricating sleeve bearing at nondrive end. 

Equipped with automatic thermal-overload switch and a thermistor.

Fans —

Two balanced, double-inlet centrifugal fans are mounted on motor shaft; directs airflow over heating element at 71 cfm.

Fan Housing —

 Fire-retardant black molded plastic.

Heating Element — 

Two coiled nickel-chrome heating elements are mounted in mica frame and protected by automatic thermal-overload switches. 

B-38030

230V

TrimLineSeries™

RECESSED PAPER TOWEL 

DISPENSER, AUTOMATIC HAND 

DRYER, AND WASTE BIN

(3-IN-1 UNIT)

Automatic Hand Dryer: 208–240V AC,

3.6-4.0 Amp, 750-950 Watts, 50/60 Hz, Single Phase VDE approved, CE marked, cUListed

Meets Electrical Safety Requirement: AS/NZS 60335.2.23:2004

396mm

15- 5/8"

S

S

S

S

S

S

Recommended Mounting Height Off Floor

for United Kingdom BS8300:2009 

1567 to 1674mm     61-11/16" to 65-7/8"

219mm

8-5/8"

89mm

3-1/2"

Typ.

22mm

.88"

Diameter

Hole for 

Between-Wall

Wirirng

1450mm

57-1/16"

Dryer

Sensor

Dryer

Outlets

Lock

& Key

Removable

Waste Bin

25mm

1"

Typ.

346mm

13-5/8"

Finish Face of Floor

Paper

Towel

Dispenser

96mm

3-13/16"

280mm

11"

Finish Face of Wall

14mm

9/16"

Typ.

280mm

11"

62mm

2-7/16"

407mm

16"

34mm

1-3/8"

Typ.

16mm

5/8"

22mm

.88"

Diameter

Hole for 

Between-Wall

Wirirng

1398mm

55"

100mm

3-15/16"

Recommended Mounting Height Off Floor

for A

ustralian DD

A standar

ds,

 AS1428.1-2009 

1667 to 1774mm     65-5/8" to 69-13/16"

727mm

28-5/8"

Rough Wall Opening

362mm (14-1/4") wide

1412mm (55-9/16") high

100mm (4") minimum

recessed depth

Summary of Contents for TrimLineSeries

Page 1: ...over is secured to mounting base with two pan head stainless steel screws Mounting Base 1 5mm 20 gauge plated steel with three 6mm 0 236 diameter mounting holes Motor Universal 1 7 hp 8000 rpm on resilient mounting Sealed ball bearing at drive shaft end and self lubricating sleeve bearing at nondrive end Equipped with automatic thermal overload switch and a thermistor Fans Two balanced double inle...

Page 2: ...ect movement within 100mm 4 of air outlet nozzle Use caution when choosing installation location Consider proximity to doorways and other traffic areas For installation instructions that include step by step installation procedures and details of electrical service connections see Form No 38030 69 which is packed with each shipment This form is also available in advance upon request SPECIFICATION ...

Page 3: ...n Fabricado en acero chapado con 3 agujeros de 6 mm 0 236 de diámetro para los tornillos de instalación Motor Universal 1 7 hp 8000 rpm Cuenta con rolineras selladas en ambos extremos del eje de transmisión y sistema de auto lubricación Equipado con un interruptor automático de sobrecarga térmica y termistor Ventilador Cuenta con 2 ventiladores centrífugos de doble entrada instalados sobre el eje ...

Page 4: ...ga cuidado al elegir la ubicación para el secador en áreas confinadas Tome en cuenta la proximidad de las puertas y otras áreas de tráfico Para obtener instrucciones de instalación paso a paso incluyendo los detalles de las conexiones eléctricas vea el Formulario Nº 38030 69 enviado con cada pedido Este formulario también está disponible con antelación por pedido ESPECIFICACIONES Unidad Empotrada ...

Page 5: ...lech 1 5 mm dick mit drei Montagebohrungen von 6 mm Durchmesser Motor Universal 1 7 HP 8000 U min auf Puffern gelagert Gekapselte Kugellager an der Antriebsseite und selbstschmierende Gleitlager an der anderen Seite Ausgestattet mit einem automatischen Überhitzungsschutzschalter und einem Thermistor Gebläse Zwei ausgewuchtete Zentrifugalgebläse mit zwei Einlässen sind auf einer Motorwelle angebrac...

Page 6: ...eichneten Klemmen an Hinweise Der elektronische Sensor erfasst Bewegungen innerhalb eines Bereichs von 100 mm vor der Luftaustrittsdüse Wählen Sie den Aufstellungsort mit Bedacht aus Die Nähe zu Türen und anderen stark frequentierten Bereichen entsprechend berücksichtigen Detaillierte Installationsanleitungen in denen die Vorgehensweise Schritt für Schritt erläutert und die Verdrahtung ausführlich...