User’s Manual

Blue Water Group (Pty) Ltd

Summary of Contents for OL70-585E

Page 1: ...OL70 585E Executive Standard GB T 19411 2003 Blue Water Group Pty Ltd Tel 27 0 74 318 1808 Email sales bluewater biz Web www bluewater biz User s Manual Blue Water Group Pty Ltd ...

Page 2: ...isture reduces the level of humidity in the air Lightweight portable design low temperature operation automatic defrosting 5 C Room Temp 12 C defrost per 30 minutes 12 C Room Temp 20 C defrost per 45 minutes Selectable humidity Could set different humidity level according to your requirement Anion design Electrostatic dust removal clean air sterilization function OL70 585E Important Please read al...

Page 3: ...our fingers or other items into air inlet or outlet 8 Do not sit on this machine 9 Drain the tank as required before move the unit 10 Install drain pip properly then water can be drain continuously 11 Please contact us or your local services if power plug damaged 12 Do not use the unit at place that long time no unsupervised 13 Unplug power cord when the machine is not used 1 Keep the appliance in...

Page 4: ...Automatic dehumidification Press this button to enter auto mode could adjust humidity manually auto adjust wind speed Indicator light is green when enter into auto dehumidification mode dehumidification Up button Press this button to adjust humidity and set time Humidity adjustment sequence is 50 55 60 65 70 75 80 85 90 95 Down button Press this button to adjust humidity and set time Humidity adju...

Page 5: ...k must be emptied Water tank emptied 1 2 Empty the water in tank 2 Clean water tank with cold water or warm water do not use detergent steel wool dust cloth gasoline benzene diluent or other solvents to clean tank May damage the water tank and cause a leakage 3 When install water tank press it tightly If tank is not placed properly full water sensor will alarm the unit will not work Continuous wat...

Page 6: ...panel clean automatic water drain outlet Remove shell connect water pump properly Remove shell replace pump Please contact us if need any support Please do not diisassembling machine repair athout authorization When the machine runs or stops it hears the sound of refrigeration circulation which is normal not failure It is normal for air outlet to exhaust hot air If water tank drainage do not have ...