background image

180.OM.CL26.FS.IPI E v1.02

September 6, 2017

CLARITY 26.FS.IPI

FREESTANDING DIRECT VENTED GAS ROOM HEATER

with Intermittent Pilot Ignition (IPI)

For use with natural gas (NG) or propane (LPG)

Installer: Please complete the details on the back cover

and leave this manual with the homeowner.

Homeowner: Please keep these instructions for future reference.

Pour la version française de nos manuels S.V.P. vous référez à notre site web: www.blazeking.com

OPERATION & 

INSTALLATION 

MANUAL

WARNING:

 

If the information in these 

instructions are not followed exactly, a fi re 
or explosion may result causing property 
damage, personal injury or loss of life.

Date  Installed:  ____________

Serial No.: _____________

4011009

5007099

Содержание CLARITY 26.FS.IPI

Страница 1: ...ave this manual with the homeowner Homeowner Please keep these instructions for future reference Pour la version française de nos manuels S V P vous référez à notre site web www blazeking com OPERATION INSTALLATION MANUAL WARNING If the information in these instructions are not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Date Installed ___...

Страница 2: ... THE GLASS 15 DOOR GLASS REPLACEMENT 16 BURNER REMOVAL 17 SAFETY SCREEN REPLACEMENT 17 FUEL CONVERSION 18 INSTALLATION___________________________________________________________________________ 21 INITIAL SETUP 21 PRECAUTIONS 23 VENT TERMINATION LOCATION 23 REAR VENT INSTALLATION 24 CONVERSION TO REAR VENT 24 CLEARANCE TO COMBUSTIBLES 27 GAS CONNECTIONS 28 VERTICAL VENT INSTALLATION 30 VENTING 31 ...

Страница 3: ...could result in death serious bodily injury and or property damage GENERAL Installation and repair should be done by a qualified service person The appliance should be inspected before the first use and at least annually by a qualified service person More frequent cleaning may be required due to excessive lint from carpeting bedding material etc It is imperative the control compartments burners and c...

Страница 4: ...Code CSA B149 1 in Canada A manufactured home USA only or mobile home OEM installation must conform with the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 or when such a standard is not applicable the Standard for Manufactured Home Installations ANSI NCSBCS A225 1 or Standard for Gas Equipped Recreational Vehicles and Mobile Housing CSA Z240 4 Always connect this gas ap...

Страница 5: ...nce installer This appliance is certified for installation in a bedroom or a bedsitting room This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes This appliance is not convertible for use with other gases unless a certified kit is used Only for direct d...

Страница 6: ...pareil doit être installé selon les codes locaux s il y en a sinon suivez l actuel ANSI Z223 1 NFPA 54 ou Gaz Naturel et Propane Codes CSA B149 1 MISE EN GARDE Une mauvaise installation un ajustement une altération service ou entretien peuvent causer des blessures ou des dommages à la propriété Consultez le manuel du propriétaire fourni avec cet appareil Pour assistance ou information additionnell...

Страница 7: ...R AWHILE MAY CAUSE CONDENSATION TO APPEAR ON THE GLASS THIS IS A NORMAL OCCURRENCE AS YOUR APPLIANCE HEATS UP NOTE RATING AND LIGHTING INSTRUCTION LABELS ARE LOCATED ON THE LOWER RIGHT AND LEFT OUTSIDE PANELS TO REMOVE LIFT UP AND OFF NOTE THIS FIREPLACE IS SUITABLE FOR INSTALLATION ON A COMBUSTIBLE SURFACE MAY BE INSTALLED ON CARPET ...

Страница 8: ...hermostat to the lowest setting 3 Turn off all electric power to the appliance 4 Do not attempt to light the pilot by hand 5 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above If you don t smell gas go to the next step 6 You must now synchronize the remote with the Receiver Battery Pack for 1st time use b...

Страница 9: ...VE 1 ON OFF solenoid EV1 terminals 2 ON OFF solenoid EV2 terminals 3 Inlet pressure test point 4 Outlet pressure test point 5 c Electrical pressure modulator device 6 Pressure modulator device terminal 7 Pilot adjusting screw 8 Pilot outlet 9 Gas inlet with protective seal 10 Gas outlet with protective seal 11 Ground connection 12 Mounting holes ...

Страница 10: ...1 A Mode Key is provided to index between the features and a Thermostat Key is used to turn on off or index through Thermostat functions Fig 1 2 Additionally a Key Lock feature is provided Fig 17 page 14 THE TRANSMITTER AND RECEIVER ARE RADIO FREQUENCY DEVICES PLACING THE TRANSMITTER IN OR NEAR METAL MAY SEVERELY REDUCE THE SIGNAL RANGE METALLIC STRUCTURES OR RADIO INTERFERENCES CAN REDUCE THE OPER...

Страница 11: ...180 OM CL26 FS IPI E v1 02 September 6 2017 Page 11 Clarity 26 FS IPI ...

Страница 12: ... be controlled with the Transmitter The fan speed can be adjusted through six 6 speeds To control the fan press the MODE key Fig 1 to index to the fan control icon Fig 15 Use UP DOWN arrow keys to turn on off or adjust the fan speed Fig 16 A single beep from the IFC will confirm the command has been received ...

Страница 13: ...180 OM CL26 FS IPI E v1 02 September 6 2017 Page 13 Clarity 26 FS IPI ...

Страница 14: ...epted for use by the system See Initializing the System for the first time below PRG Key 3 Position Slider ON REMOTE OFF INITIALIZING THE TRANSMITTER RECEIVER LINK SYSTEM FOR THE FIRST TIME Install the 4 AA batteries into the Proflame 2 Battery holder battery bay it is located behind the magnetic pull down flap that is directly below the firebox Note the polarity of the battery and insert into the bat...

Страница 15: ...clear and clean Check the pilot assembly to make sure it is not blocked by anything 4 Completely inspect the appliance and the venting system 5 Check the safety system of the gas valve CLEANING SURFACES Painted powder coated or porcelain enameled surfaces should be wiped with a damp cloth periodically Ensure the appliance has cooled down completely before any cleaning Do not use other cleaners as ...

Страница 16: ...door tabs 4 Carefully slide the door glass assembly up and out of the unit Fig 2 DOOR GLASS REPLACEMENT This glass in this appliance is a 5 mm high temperature ceramic glass that will easily withstand the heat that is produced In the event the glass breaks or cracks contact your dealer to arrange for your glass to be replaced with a factory replacement see PARTS LIST Do not operate this appliance ...

Страница 17: ...from the right hand side of the burner assembly Fig 3 7 Move the burner to the right up and out To re install the burner follow steps 1 to 7 in reverse SAFETY SCREEN REPLACEMENT The CLARITY 26 FS is supplied with a safety screen pre installed behind the front legs If the safety screen becomes damaged it must be replaced with part 645 1821 1 Turn off the appliance and allow it to cool down completel...

Страница 18: ...urner orifice with a smaller size for installations over 4500 feet 1370 m The appliances input should be reduced 4 for each additional 1000 feet 305 m above sea level For the USA de rate the unit from sea level according to the gas installation code MAINTENANCE and SERVICE cont THIS CONVERSION KIT SHALL BE INSTALLED BY A QUALIFIED SERVICE AGENCY IN ACCORDANCE WITH THE MANUFACTURER S INSTRUCTIONS AN...

Страница 19: ...nd affix between the two labels on the control panel door All valves have been pre set and certified for installation at elevations from 0 4500 feet 1 1372m above sea level HIGH ELEVATIONS When installing this unit at higher elevations it is necessary to decrease the input rating by replacing the existing burner orifice with a smaller size for installations over 4500 feet 1370 m The appliances input s...

Страница 20: ...180 OM CL26 FS IPI E v1 02 September 6 2017 Page 20 Clarity 26 FS IPI MAINTENANCE and SERVICE cont ...

Страница 21: ...Fig 1 Pull the tabs forward and up off the door tabs 3 Carefully slide the door glass assembly up and out of the appliance Fig 2 NOTE REMOVE THE STATIC CLING LABEL THAT IS ON THE DOOR GLASS Hold glass to frame when removing as it is only held in place with silicone Set the door aside 4 Slide the safety screen up and out from appliance and set aside Fig 3 5 Remove packaged contents from firebox and u...

Страница 22: ...LE GLASS CAREFULLY BY THE EDGES DO NOT LEAVE FINGERPRINTS CLEAN IF NECESSARY 8 Repeat Step 7 for the right side panel 9 Carefully place the floor plate assembly back into position Fig 6 10 Place the floor glass on top of the floor plate assembly Fig 7 NOTE SMOOTH SIDE SHOULD FACE UP 11 If installing the optional log set Fig 8 refer to installation instructions on Page 39 if not continue below 12 Repe...

Страница 23: ...ing and heating or air conditioning ducts Select a location that is accessible for venting see ALLOWABLE TERMINATION LOCATIONS VENT TERMINATION LOCATION Establish a suitable vent termination location see ALLOWABLE TERMINATION LOCATIONS In heavy snowfall areas make sure vent termination is located where it will not be blocked by snowfall or snow from snow removal equipment Locate vent termination a...

Страница 24: ... 1 Remove the top assembly from the appliance and set aside REAR VENT INSTALLATION Two snorkels are available that can be used in a rear vent application on the CLARITY 26 FS One is the M G Duravent 46DVA H2 SNK36 Fig 9 and the other is the Selkirk 4DT ST36 Fig 10 Fig 9 Fig 10 INSTALLATION cont ...

Страница 25: ...emove screws from top rear grill assembly 1 screw each side of leg two screws each side of flue collar 3 Remove top rear grill assembly from appliance and set aside 4 Unscrew outer rear shield from appliance 9 screws Be sure to undo wire clamp before attempting to remove the shield WIRE CLAMP ...

Страница 26: ...t 5 Rotate outer rear shield and place below such that the connected wires are not compromised 6 Remove screws from flue collar 6 screws 7 Rotate flue collar as shown and re install to appliance 6 screws 8 Re install rear shield and top rear grill assembly follow steps 1 3 in reverse order ...

Страница 27: ...wall 2 51 mm B Back of unit to back wall 2 5 64 mm C Corner of unit to sidewall 2 51 mm D Top of unit to alcove ceiling 33 838 mm E Alcove width 27 875 708 mm F Alcove height 70 5 1791 mm G Vent 1 25 mm from outside surface NOTE CHECK LOCAL CODES FOR FLOOR REQUIREMENTS THIS FIREPLACE IS SUITABLE FOR INSTALLATION ON A COMBUSTIBLE SURFACE ...

Страница 28: ... 5 KPA FAILURE TO DO SO WILL DAMAGE THE APPLIANCE S GAS VALVE SUCH DAMAGE IS NOT COVER BY THE MANUFACTURER S WARRANTY Check for proper gas supply pressure by loosening the set screw on supply pressure tap on the gas valve with a small flat tip screw driver and placing a test gauge on the tap The minimum permissible gas supply pressure is 5 0 in w c 1 24 kPa for natural gas and 12 0 in w c 3 0 kPa f...

Страница 29: ...AUSE POOR COMBUSTION AND OR HIGH TEMPERATURES THAT MAY PRESENT A FIRE HAZARD Mark a 10 x 10 square around the center mark inside dimensions Cut and frame the exterior wall to accept the wall penetration heat shield Install the penetration shield using wood screws If the wall being penetrated is constructed of non combustible material a 7 hole is acceptable for the vent pipe CAUTION When installing...

Страница 30: ...flat ceiling install a Box Wall thimble Cut a 10 square hole and frame as shown in the diagram opposite Ensure all pipe sections are fully twist locked NOTE Always check your local codes before installing venting Necessary clearances and requirements may vary from state to state province to province Through Roof Framing Maintain 10 opening relative to the pitch of the roof Install the flashing with ...

Страница 31: ...ME APPEARANCE The total horizontal run up to 20 6 09 m maximum Note 2 0 6m minimum of vertical height required NOTE Maximum vent lengths may be subject to local codes For best venting performance here are some general venting rules 1 Use only vent systems and components certified for use with this appliance 2 Maintain a minimum of 1 26 mm clearance to combustibles from the outside surfaces of verti...

Страница 32: ...AL VENTING Example 1 V Value 3A 12 1C 3 15 H Value 2B 4 4 V Value Total length of all vertical sections in feet H Value Total length of all horizontal sections in feet Note for H V values for 45º venting see Chart IV elbows are not counted in H or V values vent chart starts from the top of the unit CHART IV ...

Страница 33: ...26 FS IPI E v1 02 September 6 2017 Page 33 Clarity 26 FS IPI INSTALLATION INSTRUCTIONS cont VENT TERMINATION RESTRICTIONS Fig 13 VENT TERMINATION RESTRICTIONS REFER TO Table 1 Table 1 VENT TERMINATION CLEARANCES ...

Страница 34: ...ory installations a ceiling firestop is required at the second floor and any subsequent floors Fig 15 The opening should be framed to 10 254 mm x 10 254 mm inside dimensions in the same manner as shown in Fig 12 Any occupied areas above the first floor including closets and storage spaces which the vertical vent passes through must be enclosed The enclosure may be framed and sheet rocked with standard ...

Страница 35: ...vent restriction is necessary it can be adjusted as follows 1 Turn off the appliance and allow it to cool down completely 2 Remove the top lid assembly from the top of the appliance and set it aside 3 Unscrew the restrictor screw and set it aside 4 Adjust the restrictor tab to one of the six holes to obtain desired flame and screw restrictor screw back into restrictor tab 5 Reinstall the top lid ass...

Страница 36: ... correct flames are achieved Slide the air shutter to the right to reduce the amount of air 4 Flames that are very orange with tall dark stringy tips are not getting enough air Therefore the air shutter should be opened slightly until the correct flames are achieved Slide the air shutter to the left to increase the amount of air 5 Tighten air shutter lock screw BURNER FLAME APPEARANCE The ideal flame...

Страница 37: ...EGRITY OF THE MANUFACTURED HOME S FLOOR WALL AND CEILING ROOF MUST BE MAINTAINED Fig 18 ELECTRICAL REQUIREMENTS For CLARITY 26 FS IPI and Z5177 SP FAN KIT ELECTRICAL GROUNDING INSTRUCTIONS THIS APPLIANCE IS EQUIPPED WITH A THREE PRONG GROUNDING PLUG FOR YOUR PROTECTION AGAINST SHOCK HAZARD AND SHOULD BE PLUGGED DIRECTLY INTO A PROPERLY GROUNDED THREE PRONG RECEPTACLE DO NOT CUT OR REMOVE THE GROUN...

Страница 38: ...84 103 BATTERY HOLDER 600 584 922 BATTERY HOLDER WIRE HARNESS 600 199 103 PF2 PILOT ASM Z5177 IPI OR Z5177 SP OPTIONAL BLOWER 600 885 009 PF2 VALVE 600 584 924 MAIN WIRE HARNESS 600 584 045 PROFLAME TRANSMITTER CONFIGURATION FOR CLARITY 26 FS IPI INSTALLATION INSTRUCTIONS cont ...

Страница 39: ... THESE LOGS ARE NOT POSITIONED IN THEIR APPROVED LOCATIONS IF LOGS ARE BROKEN DO NOT OPERATE THE UNIT UNTIL THEY ARE REPLACED 1 How the firebox looks with only the glass floor plate in place Fig 1 2 The optional log set contains five different log shapes Make sure that the log pieces sit behind and in front of the burner It is important that the logs should not interfere with the burner flame or pilot ...

Страница 40: ...ter V shaped log onto the previous two logs as shown Fig 3 4 Position the front left log as shown Fig 4 DO NOT IMPINGE FLAME WITH LOG it should be just in front of the burner 5 Position the remaining front right log as shown Fig 5 Stand log on short branch and flat DO NOT IMPINGE FLAME WITH LOG it should be just in front of the burner ...

Страница 41: ...03 48 Pipe Length Black 46DVA 48B 902B 48 Pipe Length Galvanized 46DVA 48 902 11 14 5 8 Adjustable Pipe Length Black 911B 17 24 Adjustable Pipe Length Black 917B 45 Elbow Black 46DVA E45B 945B 945BG 45 Elbow Galvanized 46DVA E45 945 945G 90 Elbow Galvanized 46DVA E90 990 990G 90 Elbow Black 46DVA E90B 990B 990BG Vertical High Wind Termination Cap must be used for all vertical terminations 46 DVA V...

Страница 42: ... PRO FORM DV ADJUSTABLE PIPE EXTENSION BLACK 94610616A 4 to 16 GALVANIZED PRO FORM DV ADJUSTABLE PIPE EXTENSION 94610616AB 4 to 16 GALVANIZED PRO FORM DV ADJUSTABLE PIPE EXTENSION BLACK DIRECT VENT ELBOWS 94620630 30 DEG GALVANIZED PRO FORM DV ELBOW 94620630B 30 DEG GALVANIZED PRO FORM DV ELBOW BLACK 94620645 45 DEG GALVANIZED PRO FORM DV ELBOW 94620645B 45 DEG GALVANIZED PRO FORM DV ELBOW BLACK 9...

Страница 43: ... DV CEILING FIRESTOP Attic Insulation Shield 94930620A 4 INSIDE 6 5 8 PRO FORM DV ATTIC INSULATION SHIELD Adjustable Cathedral Celing Support Kit 949506KT 4 INSIDE 6 5 8 PRO FORM DV CATHEDRAL CEILING SUPPORT KIT Decorator Collar 94940612 4 INSIDE 6 5 8 PRO FORM DV DECORATOR COLLAR SS Counter Flashing 4 Pc Kit 94820615S 4 INSIDE 6 5 8 PRO FORM DV SS COUNTER FLASHING 4 PC KIT SS Vinyl Siding Standoff...

Страница 44: ...4082 4DT AJ12 DIRECT TEMP 12 ADJ PIPE LENGTH 1604082B 4DT AJ12B DIRECT TEMP 12 ADJ PIPE LENGTH BLACK 1604084 4DT TL14 DIRECT TEMP TELESCOPIC LENGTH 14 22 1604084B 4DT TL14B DIRECT TEMP TELESCOPIC LEN BLACK 14 22 1604086 4DT TL38 DIRECT TEMP TELESCOPIC LENGTH 38 70 1604086B 4DT TL38B DIRECT TEMP TELESCOPIC LEN 38 70 BLACK 4 x 6 5 8 FITTINGS 1604215 4DT EL45 45 DEGREE ELBOW 1604215B 4DT EL45B 45 DEG...

Страница 45: ...90L 90 Elbow 4D7B 7 Length Black 4D90LB 90 Elbow Black 4D12 12 Length 4DWT Wall Thimble 4D12B 12 Length Black 4DVC Vertical Cap 4D2 24 Length 502672 Horizontal Cap Square 4DHCS 4D2B 24 Length Black 4D36S Siding Shield for 4DHCS 4DHVS 4D3 36 Length 4DHWS Wind Screen 4D3B 36 Length Black 4DWS Wall Strap 4D4 48 Length 4DFSP Firestop Support Plate 4D4B 48 Length Black 4DF Flashing 0 12 6 12 Pitch 4D7A...

Страница 46: ...oping Section VDV 04MT 4 Medium Telescoping Section VDV 04ST 4 Small Telescoping Section VDV AIS04 4 Attic Insulation Shield VDV CAC04 4 Co Linear Appliance Adapter VDV CRS04 4 Round Support Box VDV CSS04 4 Square Support Box VDV EL0445 4 x 45 Deg Direct Vent Elbow VDV EL0445 6 4 x 45 Deg DV Elbow 6 Pack VDV EL0490 4 x 90 Deg Direct Vent Elbow VDV EL0490 6 4 x 90 Deg DV Elbow 6 Pack VDV F0406 4 0 ...

Страница 47: ...k TC 4DL3B 48 Length Galvalume TC 4DL4 48 Length Black TC 4DL4B 4 x 6 5 8 ELBOWS Elbow 45º Galvalume TE 4DE45 Elbow 45º Black TE 4DE45B Elbow 90º Galvalume TE 4DE90 Elbow 90º Black TE 4DE90B Slip Elbow 90º TE 4DE90S Slip Elbow 90º Black TE 4DE90SB 4 x 6 5 8 SUPPORTS FIRESTOPS Square Support Radiation Shield TM 4SS Round Support Radiation Shield TM 4RDS Ceiling Support Firestop TM 4CS Insulated Wal...

Страница 48: ...1 ground Fig 1 4 Undo the gas lines one in two out and pilot 5 Disconnect all electrical connections to valve including ground wire 6 Remove the four screws holding the valve and valve bracket to the firebox bottom and remove valve Fig 2 7 Installation is the reverse order of the previous steps NOTE WHEN INSTALLING NEW VALVE CHECK IF ANY UNUSED PORTS ARE PLUGGED CHECK OUTLET PRESSURE 3 8 W C AND CH...

Страница 49: ... 0501 L GLASS CERAM MIRROR LEFT 12 Z5104 FLOOR PLATE RIVET ASSEMBLY 4 620 5101 CERAMIC PANEL REAR CLARITY 13 640 5101 BURNER ASSEMBLY 5 130 0501 R GLASS CERAM MIRROR RIGHT 14 600 574 103 PF2 IFC BATTERY HOLDER 6 155 0184 GASKET CERAM BLACK BURNER 15 600 584 326 PF2 IFC BOARD 7 130 0601 BLACK FLOOR GLASS 16 600 885 009 PF2 VALVE W STEPPER MOTOR 8 130 0242 DOOR GLASS 17 600 584 045 PF2 WALL MOUNT TR...

Страница 50: ...e system is reset 2 Low battery condition 4V the LED indicator will blink one 1 time in intervals 3 Parasitic Pilot Flame the LED indicator will blink two 2 times in intervals 4 System Lock out the LED indicator will blink three 3 times in intervals Additional Ignition Information 1 The Proflame2 IFC will try two 2 times for ignition 2 Each try for ignition will last approximately 60 seconds 3 The ...

Страница 51: ...alve wirings and connections to the board Check the pilot burner for obstruction Check the wirings and connections between the pilot assembly and the board Check the correct gas type settings on the valve and pilot burner assembly orifice Pilot will not remain lit Problem with Flame Sensor circuit Check for proper connection of the Flame Sensor to the IFC board Check pilot for full flame impingement...

Страница 52: ...impingement on thermopile Flame lifting Leak in vent pipe Check for leaks in vent connections Improper vent configuration Check vent configuration with manual Terminal may be re circulating flue gases Check to see if terminal is on correctly May need to install high wind termination cap Contact dealer Blue Flames The heater has just been started Normal during start up flame will yellow as the fireplace...

Страница 53: ...for replacement parts Warranty Period Components Covered Parts Labor Gas 1 Year X All parts materials and surface finishes flaking and peeling Except as covered by Conditions Exclusion and Limitations listed 2 Years X Igniters Thermocouple Thermopile Molded Refractory Panels Log sets Fan assembly Ignition components Gas valve Burner components Thermostat 5 Years 2 Years X Firebox Heat Exchanger 10 Y...

Страница 54: ... and exclusions apply to this warranty Limited One 1 Year Warranty Under this warranty Blaze King covers all exterior surface finishes against defects in materials and workmanship for part repair or replacement and limited labor for the first 1 year to the original purchaser Please see the exclusions and limitations section below as certain restrictions and exclusions apply to this warranty How the ...

Страница 55: ...y on this stove If unsure as to the extent of this Limited Warranty contact your authorized Blaze King dealer before installation 9 Blaze King will not be responsible for inadequate performance caused by environmental conditions 10 The Limited Warranty does not cover installation and operational related problems such as use of downdrafts or spillage caused by environmental conditions Environmental...

Страница 56: ...antable Blaze King will not be liable for travel costs for service work In the event of in home repair work the customer will pay any in home travel fees or service charges required by the Authorized Dealer 27 At no time will Blaze King be liable for any consequential damages which exceed the purchase price of the unit Blaze King has no obligation to enhance or modify any stove once manufactured e...

Отзывы: