background image

1000 Park Drive     •     Lawrence, PA 15055-1018      •     724-746-5500     •     Fax 724-746-0746

© Copyright 2000. Black Box Corporation. All rights reserved.

Summary of Contents for PS186A

Page 1: ...1000 Park Drive Lawrence PA 15055 1018 724 746 5500 Fax 724 746 0746 Copyright 2000 Black Box Corporation All rights reserved ...

Page 2: ... 746 5500 or fax 724 746 0746 Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail info blackbox com OCTOBER 2000 PS186A SP198A PS187A R2 SP199A PS188A SP211A PS189A SP215A SP187A SP216A SP197A SP217A SP218A 19 Rack Mount Power Strips and Surge Suppressors 48 70 77 Vertical Power Strips and Surge Suppressors ...

Page 3: ......

Page 4: ...is own expense will be required to take whatever measures may be necessary to correct the interference Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation o...

Page 5: ...icante 7 El aparato eléctrico debe ser montado a la pared o al techo sólo como sea recomendado por el fabricante 8 Servicio El usuario no debe intentar dar servicio al equipo eléctrico más allá a lo descrito en las instrucciones de operación Todo otro servicio deberá ser referido a personal de servicio calificado 9 El aparato eléctrico debe ser situado de tal manera que su posición no interfiera s...

Page 6: ...r una antena externa deberá ser localizada lejos de las lineas de energia 16 El cable de corriente deberá ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo 17 Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilación 18 Servicio por personal calificado deberá ser provisto cuando A El cable de poder o ...

Page 7: ...ANUAL National Electric Code is a registered trademark of the National Fire Protection Association UL is a registered trademark of Underwriters Laboratories Incorporated Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark owners ...

Page 8: ...ppressor SP211A or SP215A 15 2 2 1 19 Rack Surge Power Strip SP187A 15 2 2 2 400 Volt Rack Mount Surge Suppressor Switchless SP211A 15 2 2 3 Premium Rack Mount Surge Suppressor SP215A 16 2 3 About Your Vertical Surge Suppressor Strip 16 2 3 1 Vertical Surge Suppressor Strip SP197A SP198A SP199A 17 2 3 2 Vertical Surge Suppressor Strip SP216A SP217A SP218A 17 3 Installation 19 3 1 Installing Most M...

Page 9: ... AWG 3 conductor cord with NEMA 5 15 male plug Outlets 6 Front mounted NEMA 5 15Rs Size 1 8 H x 19 W x 2 8 D 4 6 x 48 3 x 7 1 cm Weight 2 5 lb 1 1 kg PS187A R2 70 Vertical Power Strip Compliance FCC Class A DOC Class MDC classe A UL listed CSA certified UR recognized Power 120 VAC Rated Current 15 amps has side mounted resettable breaker Input 1 6 ft 1 8 m 14 3 14 AWG 3 conductor cord with NEMA 5 ...

Page 10: ...19 W x 2 8 D 4 6 x 48 3 x 7 1 cm Weight 2 5 lb 1 1 kg PS189A Rack Mount Power Strip Front Access Compliance FCC Class A IC Class classe A UR recognized CSA certified Power 120 VAC Rated Current 15 amps has front mounted resettable breaker Control 1 Front mounted ON OFF switch lights when ON Input 1 6 ft 1 8 m 14 3 14 AWG 3 conductor cord with NEMA 5 15 male plug Outlets 6 Front mounted NEMA 5 15Rs...

Page 11: ...y 400 volts peak transient voltage Actual clamp voltage 336 volts peak Maximum surge energy resistance 13 000 amps EMI RFI resistance Up to 40 dB Control 1 Front mounted ON OFF switch lights when ON Indicator 1 Front mounted Protection LED goes dark when unit s protection circuitry has absorbed surge and been destroyed Input 1 6 ft 1 8 m 14 3 14 AWG 3 conductor cord with NEMA 5 15 male plug Outlet...

Page 12: ...transient voltage Actual clamp voltage 336 volts peak Maximum surge energy resistance 13 000 amps Fail safety Unit automatically shuts OFF power to its outlets if surge suppression fails EMI RFI resistance Up to 40 dB Indicator 1 Front mounted Protection LED goes dark when unit s protection circuitry has absorbed surge and been destroyed Input 1 6 ft 1 8 m 14 3 14 AWG 3 conductor cord with NEMA 5 ...

Page 13: ...our stage hybrid UL 1449 clamping category 330 volts peak transient voltage Actual clamp voltage 260 volts peak Maximum surge energy resistance 33 000 amps EMI RFI resistance Up to 60 dB Indicator 1 Front mounted Protection LED goes dark when unit s protection circuitry has absorbed surge and been destroyed Input 1 6 ft 1 8 m 14 3 14 AWG 3 conductor cord with NEMA 5 15 male plug Outlets 6 Rear mou...

Page 14: ...e 312 volts peak Maximum surge energy resistance 13 000 amps EMI RFI resistance Up to 40 dB Indicator 1 Front mounted Protection LED goes dark when unit s protection circuitry has absorbed surge and been destroyed Input 1 6 ft 1 8 m 14 3 14 AWG 3 conductor cord with NEMA 5 15 male plug Outlets SP197A 10 Front mounted NEMA 5 15Rs SP198A 11 Front mounted NEMA 5 15Rs SP199A 12 Front mounted NEMA 5 15...

Page 15: ...mp voltage 312 volts peak Maximum surge energy resistance 13 000 amps EMI RFI resistance Up to 40 dB Indicator 1 Front mounted Protection LED goes dark when unit s protection circuitry has absorbed surge and been destroyed Input 1 15 ft 4 6 m 14 3 14 AWG 3 conductor cord with NEMA 5 15 male plug Outlets SP216A 10 Front mounted NEMA 5 15Rs SP217A 11 Front mounted NEMA 5 15Rs SP218A 12 Front mounted...

Page 16: ...o not attempt to take the unit apart It contains no user serviceable parts you will void the warranty and you could very easily hurt yourself and or damage the unit If the unit is defective call your supplier as described in Chapter 4 When you unpack the unit inspect it carefully for any damage that might occur during transit If anything is damaged return the unit immediately but call your supplie...

Page 17: ...ckmountable power strip for standard 19 racks It has 6 outlets on its rear panel as well as these features Electrical and mechanical grounding Protective circuit breaker with front panel reset button but no other surge protection No power switch devices plugged into the strip can t be accidentally turned off 2 1 4 RACK POWER STRIP FRONT ACCESS PS189A The PS189A is a rackmountable power strip that ...

Page 18: ...outlets 2 2 1 19 RACK SURGE POWER STRIP SP187A The SP187A is a rackmountable power strip for standard 19 racks It has 6 outlets on its rear panel as well as these features Electrical and mechanical grounding Protective circuit breaker with front panel reset button UL 1449 400 volt clamping category actually clamps at 336 volts Resists EMI RFI up to 40 dB LED goes dark to show that the unit has don...

Page 19: ...th front panel reset button UL 1449 330 volt clamping category actually clamps at 260 volts Resists EMI RFI up to 60 dB LED goes dark to show that the unit has done its job it has taken a major surge sparing the attached devices and should be replaced No power switch devices plugged into the strip can t be accidentally turned off 2 3 About Your Vertical Surge Suppressor Strip The Vertical Surge Su...

Page 20: ... and mechanical grounding UL 1449 330 volt clamping category actually clamps at 312 volts Resists EMI RFI up to 40 dB LED goes dark to show that the unit has done its job it has taken a major surge sparing the attached devices and should be replaced No power switch devices plugged into the strip can t be accidentally turned off 2 3 2 VERTICAL SURGE SUPPRESSOR STRIP SP216A SP217A SP218A NOTE The SP...

Page 21: ...lectrical and mechanical grounding UL 1449 330 volt clamping category actually clamps at 312 volts Resists EMI RFI at up to 40 dB LED goes dark to show that the unit has done its job it has taken a major surge sparing the attached devices and should be replaced No power switch devices plugged into the strip can t be accidentally turned off ...

Page 22: ... now installed and ready to operate 3 2 Installing the PS187A R2 or Vertical Surge Suppressor Strip Follow these instructions to install your 70 Vertical Power Strip or Vertical Surge Suppressor Strip 1 Screw the mounting clips into the mounting surface 2 Place the Power Strip on the mounting clips and snap it into position so that the unit is flush with the mounting surface The unit should now be...

Page 23: ...rate assistance if you have a complete description including the nature and duration of the problem when the problem occurs the components involved in the problem any particular application that when used appears to create the problem or make it worse 4 2 Shipping and Packaging If you need to transport or ship your Power Strip Surge Power Strip or Surge Suppressor Package it carefully We recommend...

Reviews: