OPERATING AND MAINTENANCE MANUAL 

SAFETY, SERVICE & REPAIR 

 
 
 

 

 

 
 
     

 Industrial Door – Operating Manual 

 
     Insert address here 
 
 
 

 

 

 

 

 

 

 

 

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BGID.Doc.U12.020

 

 
 
 

 

Содержание Industrial Door

Страница 1: ...NITS 3 10 12 GRIFFIN INDUSTRIAL ESTATE PENNCRICKET LANE ROWLEY REGIS WEST MIDLANDS B65 0SN Tel 0121 559 8666 Fax 0121 561 1101 Web www bgid co uk OPERATING AND MAINTENANCE MANUAL SAFETY SERVICE REPAIR Industrial Door Operating Manual Insert address here BGID Doc U12 020 ...

Страница 2: ...D THIS INSTRUCTION BOOKLET PRIOR TO OPERATING YOUR INDUSTRIAL DOOR SHOULD YOU EXPERIENCE ANY DIFFICULTY PLEASE CONTACT OUR SERVICE DEPARTMENT NORMAL HOURS 0121 559 8666 OUT OF HOURS EMERGENCY NUMBER 07778 375310 ...

Страница 3: ...ase any additional locking mechanisms pull downward on the required hand chain in a controlled manner until curtain is fully open replace hand chain into lockable position and secure 2 TO CLOSE Release hand chain from lockable holder pull downward on hand chain in a controlled manner until door curtain is fully closed replace hand chain into lockable holder 3 Any Wicket gate installation MUST be h...

Страница 4: ...or curtain will automatically stop when fully closed or when the button is released 3 TO STOP Press the red Stop button 4 IN THE EVENT OF A POWER FAILURE The motor is fitted with an emergency hand chain or crank mechanism access to the motor will be required Lift hand chain or crank into position and operate manually Operation will be very slow when power is reinstated the door will not operate el...

Страница 5: ...Designed to close in the event of a fire Not designed to be used on a regular basis if however the curtain is lowered for inspection or other purposes it will be difficult to lift up refer to section A F Electrically Operated Fire Shutters Designed to close in the event of a fire for operational instructions refer to Section C SPECIAL NOTE It is now a legal requirement that ALL Fire Shutters and E...

Страница 6: ...oor operations instructions refer to section B I Electrically Operated For door operation instructions refer to section C Sliding Folding Door Operating Instructions J Manual Operation 1 TO OPEN Release any locking mechanisms and slide door fully open using the handles fixed to the leading edges 2 TO CLOSE Pull on handles attached to the leading edge until in the closed position then engage any lo...

Страница 7: ... A POWER FAILURE Power failure release mechanism on leading door edge to disengage drive chain then use as section J When power is re instated re engage drive mechanism Note A safety clutch mechanism is fitted to all electrically operated doors of this type which is activated when the door strikes an obstruction General Note BGID does not recommend fitting locking devises to electrically operated ...

Страница 8: ... with a single phase 230 250 volt tubular motor The roller is fitted with auto locking elements to hold the shutter curtain in the closed and locked position The tubular motor incorporates adjustable limit switches These limits are set so that the motor is switched off when the shutter is in either the open up or closed down position Box assembly manufactured from powder coated roll formed alumini...

Страница 9: ...nel Isolate control system whenever maintenance is being carried out Never operate the shutter unless fully in view and the area is clear Failure of components causing the shutter curtain to fall Severe injury or worse NEVER allow personnel to be in the area of the shutter when it is operating Rotating shutter when box cover removed Trapping of limbs or hair Total isolation of the electrical suppl...

Страница 10: ...d qualified BGID installation engineers GENERAL 1 Only use opening closing equipment supplied with the door 2 Keep opening clear of any obstacles when operating the door 3 DO NOT try to operate a damaged door we recommend that you call BGID Service Department who will advise the best course of action 4 DO NOT lean obstacles against the door 5 Work carried out on electrical control equipment MUST b...

Страница 11: ... relevant parts 5 check electrics i e control station gearbox and limits 6 fire doors only carry out a mechanical drop test to ensure door closes in the event of a fire 7 sliding folding doors clean out bottom track BGID provide a written report after each service visit BGID operate a specialised service and repair department with a genuine 24 7 nationwide call out facility using our own trained s...

Страница 12: ...ility is our strength BIRMINGHAM GARAGE INDUSTRIAL DOORS LTD UNITS 3 10 12 GRIFFIN INDUSTRIAL ESTATE PENNCRICKET LANE ROWLEY REGIS WEST MIDLANDS B65 0SN Tel 0121 559 8666 Fax 0121 561 1101 Web www bgid co uk ...