background image

 

 

Pool Pilot

 

Digital 48 

by Bio-Lab Canada Inc. 

 

 

DOMESTIC Chlorine Generating Device  

Installation and Operation Manual

 

 

MODEL DIG48 REGISTRATION NUMBER 28063 PEST CONTROL PRODUCTS ACT 

 

Maximum Output Equivalent To 0.82 Kg. Of Free Available Chlorine Per Day 

One DIG48 Unit Can Treat a Maximum Of 153,000 Litres Of Swimming Pool Water 

Controls Bacteria And Algae In Swimming Pool Waters 

 

(For Indoor or Outdoor Use) 

 

RETAIN MANUAL FOR FUTURE REFERENCE 

 

 

 

 

 

 
 

IMPORTANT 

NSF50

 

READ THE LABEL AND THIS MANUAL BEFORE INSTALLING & OPERATING 

Notice to User:  This control product is to be used only in accordance with the directions on this label.  It is 

an offense under the Pest Control Products Act to use a control product under unsafe conditions. 

 

Bio-Lab Canada Inc., 1005 Copperstone Drive, Pickering, ON. L1W 4A5

 

 (MINERAL SPRINGS PP DIG48 Residential English Final Nov 2004 TEMP2)

09-JUNE-2005

Summary of Contents for Pool Pilot Digital

Page 1: ...ols Bacteria And Algae In Swimming Pool Waters For Indoor or Outdoor Use RETAIN MANUAL FOR FUTURE REFERENCE IMPORTANT NSF50 C READ THE LABEL AND THIS MANUAL BEFORE INSTALLING OPERATING Notice to User...

Page 2: ..._________________ Control Unit Control Unit Model Number DIG48______________ Serial Number ____________________________ Cell Cell Model RC7 Serial Number ____________________________ Customer Assistan...

Page 3: ...chemistry in accordance with manufacturer s instructions 6 DANGER To reduce the risk of injury do not permit children to use this product unless they are closely supervised at all times Children shou...

Page 4: ...tions Remote ORP Connections 2b Cell and Manifold Installation 6 Verification of Flow Switch Protection 6 Section 3 OPERATION 3a Key Features Display Panel 7 9 3b Pool Water Preparation 10 Salt Requir...

Page 5: ...ng See page 10 for salt requirements the tri sensor assembly holes to tighten the screws RATINGS Input Power 115 VAC 3 0 AC amps MaximumOutput Equivalent to 0 82 kg 1 80 lbs of free available chlorine...

Page 6: ...e 1 Blue Bl Line 2 Green w Yellow Tracer Gr Yel Earth Ground For 115 VAC Brown Br Line Blue Bl Neutral Green w Yellow tracer Gr Yel Earth Ground The AC Line IN wiring is pre set for connection to the...

Page 7: ...that the flow switch is working as designed which is to halt power from being sent to the cell in the presence of insufficient flow A defective Flow Switch could cause serious personal and or equipme...

Page 8: ...when manually discontinued When Boost is activated with External Timer setting programmed the time remaining for the boost cycle is held in memory and will start up in Boost mode until expired With P...

Page 9: ...menu After completing a step it displays the next step 2 1 English Metric displays volume in gallons or cubic meters salt additions in lbs or kg Back Main Menu 2 0 2 2 Temperature Units displays the...

Page 10: ...d 3 7 Calibrate Salt allows you to calibrate the salt display Contact the factory for calibration solution 3 8 Replace Cell Only used when replacing cells May be used to zero the amp hour counter Cons...

Page 11: ...aCl NOTE Do not use Rock Salt due to its high levels of impurities TEST YOUR WATER FOR SALT LEVEL FIRST with the provided salt test strips and then use the chart below to determine the amount of salt...

Page 12: ...Maintain and balance only as needed CYANURIC ACID STABILIZER CONDITIONER This chemical goes by either trade name and allows your chlorine residual to last longer by protecting it from the UV degradat...

Page 13: ...and Access is gained to you do not need to wire harness Control Circuit lift off metal cover electrical connections remove these board removes with cover and fuses Fuse Location and Ratings F1 Main AC...

Page 14: ...n be treated with a mixture of one 1 part Muriatic Acid into four 4 parts water Mix the solution in a container high enough to cover the Cell blades You may also use non fuming pre mixed cell cleaner...

Page 15: ...dered separately Red Cap Plug for RC7 cell cord 19050 12 ft 3 6m Cell Cord 952 1 Union O Ring 19013 Cell RC7 Nut Half only 2 pcs for 2 in 50 mm S x S Union Thread Half Only for 2 in 50 mm S x S Union...

Page 16: ...orrosion 4 Premature Cell Failure Requires Replacement Cell A Abnormally high Cell usage due to an insufficient A Check the stabilizer level and adjust to recommended levels Stabilizer Cyanuric acid l...

Page 17: ...E OR EXPLOSION DOMESTIC READ THE LABEL AND THE INSTALLATION AND OPERATION MANUAL BEFORE USING Imported to Canada for BIO LAB CANADA INC 1005 Copperstone Drive Pickering ON L1W 4A5 REGISTRATION NO 2806...

Page 18: ...GISTRATION NUMBER 28064 PEST CONTROL PRODUCTS ACT This cell must only be used on these models of chlorine generating device Read the Label and the Installation and Operation Manual of the chlorine gen...

Page 19: ...ormation This service and this information do not replace the official hard copy label The PMRA does not provide any guarantee or assurance that the information obtained through this service is accura...

Reviews: