background image

Mariella Trapletti

Zingonia  (BG) - Italy

03/2001

The Managing Director

DECLARATION OF EEC CONFORMITY

Nuova Bianchi Spa

 - situated in via Parigi n°5, Zingonia (Bergamo) Italy, represented by Mariella Trapletti - states that the

vending machines model:

“SIRIO FRESH BREW “

are in conformity with the safety measures provided for by the Law nr. 

98/37/EEC 

dated

 

22-06-1998 in its items n.1-2-3-4 and

relative enclosures 1-2-3-5  “Safety and Health and subsequent, and 73/23/CEE and subsequent.

Nuova Bianchi has applied the Standards for the prevention and the elimination of the radio disturbances  in respect of the EEC
Standards 

89/336, 93/ 68 

and subsequent annexes and of the

 D.L. nr. 476

 and subsequent annexes , that are in conformity

with  the norms 

EN 55014 3a ed., EN 55104, ENV 50141

 and  

EN 61000

.

The Standards used for testing of  the suitability for contact with food substances are in accordance with 

DM 21-03-1973

Standards and subsequent annexes.

In general the rules of the Standards  

90/128/EEC ,73/23/CEE

 and 

89/336/CEE

 and subsequent annexes  have been

applied. The Standards used for the safety tests on electrical parts are in accordance, ref. 

CENELEC HD 251S2, 

pub.

 IEC 335-1-2

.

Summary of Contents for SIRIO FRESH BREW

Page 1: ...anchi has applied the Standards for the prevention and the elimination of the radio disturbances in respect of the EEC Standards 89 336 93 68 and subsequent annexes and of the D L nr 476 and subsequen...

Page 2: ......

Page 3: ...NUOVA BIANCHI S p A Viale Parigi 5 7 9 24040 ZINGONIA DI VERDELLINO BG ITALIA Tel 035 88 22 25 ra Fax 035 88 33 04 E mail postvendita bianchivending it Sirio FRESH BREW...

Page 4: ...ENANCE TECHNICIAN The maintenance technician is defined as being the person responsible for filling up the containers with soluble products sugar coffee stirrers and cups The maintenance technician is...

Page 5: ...5 n 7 n 8 n 10 n 20 n 22 SPANNERS fork type n 7 n 8 n 10 n 12 n 14 SCREWDRIVERS Small size Medium size Large size Normal cross Small cross Medium cross Large cross Of Teflon small size for Trimmer re...

Page 6: ...rt of the equipment and as such must always remain inside of the same so as to allow further consultations on the part of the various operators until the dismantlement and or scrapping of the machine...

Page 7: ...same be subjected to changes over time it is necessary to immediately inform the manufacturer before using the machine Also check that any other eventual norms or regulations as laid down by national...

Page 8: ...ower 1 2 85 kW Average consumption on standby for 50 drinks Water supply connection 3 8 gas Electric connection spina SCHUKO WATER SUPPLY from main supply with pressure between 0 5 and 6 5 bar CUP DIS...

Page 9: ...NERAL TECHNICAL DESCRIPTION 3 1 Machine description Fig 3 1 1 Soluble sugar drink containers 2 Fresh brew drink dispenser 3 Electronics board 4 Boiler 5 Cup column 6 Fresh brew unit 7 Cup presence det...

Page 10: ...d as suitable by the manufacturer for automatic distribution in open containers The drinks are made in specific plastic cups automatically dispensed by the machine Where foreseen a sugar stirrer is al...

Page 11: ...the cylinders is engaged and the air pump is started for the delivery of the initial quantity of water necessary for the infusion of the product The fresh brew unit then stops for the time necessary f...

Page 12: ...and by a transparent film in polypropylene Fig 4 2 The automatic distributor will be delivered packed assuring both a mechanical protection and protection against damages from the external environment...

Page 13: ...ted here below l cup column example in Fig 4 7 l coin box l coin mechanism cover CPU board l product containers l liquid dreg full float l bottom skirting board l liquid dreg bucket l remove the polys...

Page 14: ...and maintenance l not authorized modifications l improper use of the distributor l not original spare parts Furthermore verify observance of any other eventual local and national standards 6 0 INSTAL...

Page 15: ...doesn t have a difference of more than 6 the power supply output is able to bear the power load of the machine use a system of diversified protection position the machine in such a way as to ensure th...

Page 16: ...installation technician to operate in this way by inserting the special plastic key supplied with the distributor into the door switch and rotating it 90 Fig 6 12 The opening and possible connection o...

Page 17: ...th a chlorine base products that can be purchased in pharmacies carefully following the indications on the product instruction labels Remove all the product containers from the distributor Fig 6 14 Re...

Page 18: ...plying the Fresh Brew unit and should be filled according to the following configurations Version 1 Fig 6 19 TEA LEAVES menu YES Container A Coffee 1 Container B Coffee 1 Container C Tea leaves Versio...

Page 19: ...mn manually First filling In installation phase with the cup dispenser completely empty proceed as follows Check that the cup column is not aligned with the distribution outlet then fill all the colum...

Page 20: ...th the two knobs Connect the coin mechanism to the CPU board The selectors must be directly connected to the CPU board the and the serial executive systems through the interface cable supplied with th...

Page 21: ...y request will appear on the display to be entered on the keyboard The messages will be displayed in a choice of six or seven different languages as chosen by the operator during the installation stag...

Page 22: ...forward the list of the functions available in the submenu n WHITE COFFEE key or DECREASE key has the function of decreasing the value of a selected digit n CAPPUCCINO DIGIT key For moving of the dis...

Page 23: ...ease the digit with the 3rd key digit move the cursor Repeat the operations until the access code is composed Once the code is composed press the key Enter 4th so as to accede to programming il codice...

Page 24: ...or when the programmer s batteries run out l For the reading of the configuration press in sequence F 1 1 F 1 F l to update the machines memory F 1 2 F 1 F 1 F Connect and disconnect the programmer f...

Page 25: ...coffee Key Tc28 with instant coffee Key Tc with pre selection Sugar time Time for maximum sugar dose Extra milk time time for the extra milk dose Integral water time Coffee infusion time Tea infusion...

Page 26: ...amming on the display appears Price 0 0000 with the same procedure used for the dose settings the sales prices are set using the keys number For free sales it is sufficient to set the vending price to...

Page 27: ...B the discounts S0 S9 are tied to the time periods and consequently to the presence of the clock interface on the CPU board The discount for the cup is available without the presence of the clock int...

Page 28: ...ressing ENTER gives access to the programming of Price extra mil 0000 Price extra sugar 0000 these regard eventual price increases for the pre selections ex tra milk and extra sugar Vice versa selecti...

Page 29: ...ation of selections from key 01 to 20 Pressing ENTER once on the display appears Include key 01 Y with the keys and the desired option is selected DIGITISING N THE SELECTION IS EXCLUDED Press ENTER ag...

Page 30: ...ng for BDV coin mechanisms WARNING Should the BDV system not be connected the distributor will not work and the wording PERMANENT DIAGNOSIS appears in which case it is necessary to repeat the entire p...

Page 31: ...e starting the cycle at least one selection must be made Therefore at least one mixer washing cycle is guaranteed a day Jug 1 number of consecutive CONCENTRATED COFFEE drinks to be dispensed in JUG mo...

Page 32: ...espond to the same vending machine channels Press ENTER once on the display appears Coin 1 0050 with the keys e number the value is changed Press ENTER to confirm the set modification and anyhow the v...

Page 33: ...Pressing the key will take you through the menu up to the desired function pressing the enter key gives access to the first data of the function selected by pressing ENTER again gives you access to th...

Page 34: ...lation of the coffee boiler and instant boiler operating temperature On pressing ENTER the following appears for example temp water sol C 096 Use keys and and cursor to increase or decrease the temper...

Page 35: ...on factor the audits discounts the digits relating to the payment system max change max values etc which are locally programmed once the single currency comes into force only the sum in Euro will be d...

Page 36: ...tributor will remain in SERVICE mode l RESET this function cancels the faults recorded by the distributor and begins a subsequent diagnosis check to ensure that no other faults are present l FRESH BRE...

Page 37: ...rgents disinfectants and are usually sold at the chemist s On application of the HACCP certain hygienic regulations are laid down for company self checking procedures concerning Cleaning of the premis...

Page 38: ...particular the dispensing area Fig 9 7 dispensing chamber Fig 9 4 Before effecting the re assembly operations clean all the elements carefully remove all the liquid waste bags clean and or replace th...

Page 39: ...apter 6 5 Fig 9 8 9 3 Regulations 9 3 1 Regulation of the solubles solenoid water delivery valves In the case of soluble products you can regulate the quantity of water and the powder dosage electroni...

Page 40: ...d waste bucket and clean it carefully eliminate the waste dregs bag clean all the internal and external surfaces of the machine with a cloth protect the outside of the machine with a plastic film wrap...

Page 41: ...y displayed in the follow manner There is also a unit presence safety device micro switch mounted on the boiler unit support in versions with plastic unit in the absence of this unit the machine indic...

Page 42: ...6 Air solenoid valve with fixture spring 07 0208 16 Fixture spring for electro valve 16 0161 16 Pump filter 21 0148 16 Pump rubber insert 27 0036 16 Air pump 05 1367 16 FB water inlet snap couplings w...

Page 43: ...ne 8x11 Tubo silicone 8x12 Tubo pvc crist 12x16 nuova Dis nuova BIANCHI Ediz Data Cod Pompa centrifuga acqua Scatola dosatrice latte Elettrovalvole solubili Colombo Elettrovalvole gruppo fresh brew Se...

Page 44: ...Infrared cup sensor 42 42 25 40 11 0813 11 SIFB01 BIANCHI 0 nuova Foglio n 2 POUSSOIRS Bottom light Door door Low tension switch Cup distributor LOW TENSION DOOR Light Coinmech Supply 220V ALIMENTATI...

Page 45: ...ter Jug Facility Cleaning Key Service Key Coinmech First electrovalve water Cold natural water Fizzy water electrovalve First syrup Product motor fresh brew tea Inlet valve cold group Suppe product mo...

Reviews: