background image

 

1895 6

ISTRUZIONI PER L’USO

IT

INSTRUCTIONS FOR USE

EN

MODE D’EMPLOI

FR

GEBRAUCHSANWEISUNG

DE

INSTRUCCIONES

ES

INSTRUÇÕES DE USO

PT

GEBRUIKSAANWIJZING

NL

INSTRUKCJA OBSŁUGI

PL

HASZNÁLATI ÚTMUTATÓ

HU

Summary of Contents for 1895 6

Page 1: ...1895 6 ISTRUZIONI PER L USO IT INSTRUCTIONS FOR USE EN MODE D EMPLOI FR GEBRAUCHSANWEISUNG DE INSTRUCCIONES ES INSTRUÇÕES DE USO PT GEBRUIKSAANWIJZING NL INSTRUKCJA OBSŁUGI PL HASZNÁLATI ÚTMUTATÓ HU ...

Page 2: ...L DATA table Use in environments containing explosive or potentially explosive atmospheres Use in damp or wet environments exposure to rain or snow Use for any applications other than the stated ones WORK AREA SAFETY Use the cleaner in a dry area avoiding humidity Do not operate the cleaner in environments containing potentially explosive atmospheres because sparks may be generated which can ignit...

Page 3: ... reduce the effectiveness of safety measures and increase operator risk Connect the power supply cable to the mains socket checking that the mains voltage matches the voltage stated on the plate of the cleaner See TECHNICAL DATA table Do not cover the cleaner while using it Allow for an adequate amount of space for ventilation Unplug the cleaner when not in use Do not use the cleaner in humid or w...

Page 4: ...not use any detergent solutions to clean items Strong acid or alkaline cleaning solutions will cause corrosion rust or puncture of tank or machine body To overcome this problem dilute to a mild pH solution Do not drop any item into the tank as this may cause damage Always place the items to clean gently into the basket Do not overlap items while cleaning always allow plenty of clear space between ...

Page 5: ...emperature Press once to reduce the temperature by 1 C hold the key to reduce the temperature by 10 C F Degas solutions with many air bubbles affect ultrasonic action Using the Degas mode before the cleaning process is started allows air bubbles to be removed from the solution which improves cleaning efficiency G Soft 60 power for delicate applications H Normal 100 power for normal applications I ...

Page 6: ...s the Heating key to start or stop heating Press to set the temperature 1 To get the best cleaning result the recommended solution temperature is 40 60 C Warm water and detergent will soften grease and improve the cleaning result 2 When setting the temperature if the set temperature exceeds the room temperature press the Heating key Heating will be started and the indicator will turn on If the set...

Page 7: ...orking press Normal again Then both heating and ultrasonic cleaning will stop and the corresponding indicator will turn off Soft mode After the timer and temperature have been set press Soft The corresponding indicator will turn on and the device will work in Soft mode If you want to switch to the other mode just press Degas or Normal the Soft indicator will turn off and the indicator for the Dega...

Page 8: ...ctured and tested in accordance with current EU regulations It is covered by a 12 month warranty for professional use or a 24 month warranty for nonprofessional use We will repair any breakdowns caused by material or manufacturing defects by fixing the defective pieces or replacing them at our discretion Should assistance be required once or several times during the warranty period the expiry date...

Reviews: