background image

 

 

Foodservice Equipment Specialists 

P.O. Box 880 Saco, ME. / U.S.A. 04072 

877-854-8006 * FAX (207) 854-8009 

 
 

OPERATIONS AND MAINTENANCE PROCEDURES 

CONVEYOR TOASTER MODEL - JT1 & JT1-B 

 
 

FOR SERVICE ASSISTANCE 

U.S. AND CANADA CALL: 1-877-854-8006 

24 HOURS/DAY 7 DAYS/WEEK 

 
 

TABLE OF CONTENTS 

 

UNCRATNG 

AND 

INSPECTION 

    PAGE 

 

ASSEMBLY 

AND 

INSTALLATION    PAGE 

 
ELECTRICAL 

INSTALLATION 

    PAGE 

 

POWER 

SAVER 

FEATURE 

     PAGE 

 
TOASTING 

PROCEDURE 

     PAGE 

 
CLEANING 

(DAILY 

WEEKLY) 

    PAGE 

 
 GENERAL 

MAINTENANCE 

PAGE 

 
 

TROUBLESHOOTING GUIDE 

PAGE 4 

 
 

SPARE PARTS LISTINGS 

PAGE 5 

 
 
 
 
 
 

 
 

5-20-05 RJB 

Summary of Contents for JT1

Page 1: ...R SERVICE ASSISTANCE U S AND CANADA CALL 1 877 854 8006 24 HOURS DAY 7 DAYS WEEK TABLE OF CONTENTS UNCRATNG AND INSPECTION PAGE 1 ASSEMBLY AND INSTALLATION PAGE 1 ELECTRICAL INSTALLATION PAGE 1 POWER SAVER FEATURE PAGE 2 TOASTING PROCEDURE PAGE 2 CLEANING DAILY WEEKLY PAGE 2 GENERAL MAINTENANCE PAGE 3 TROUBLESHOOTING GUIDE PAGE 4 SPARE PARTS LISTINGS PAGE 5 5 20 05 RJB ...

Page 2: ...77 854 8006 CAUTION During installation Do not place on surfaces or near walls partitions or kitchen furniture and the like unless they are made of non combustible material or clad with non combustible heat insulating material and pay attention to fire prevention regulations Bread may burn Therefore toasters must not be used near or below curtains and other combustible materials They must be watch...

Page 3: ...r knob to the Full Power position Set the Conveyor Speed Control knob to 50 Allow 10 15 minutes to heat from cold Place a sample of the desired product on the Conveyor Belt to test the settings If toasting is too light turn the Speed Control counterclockwise to a slower speed If toasting is too dark turn the Speed Control clockwise to a faster speed Buns Bagels and English Muffins may be tested th...

Page 4: ...NANCE 1 REPLACING HEATER TUBES Tip replace only one tube at a time to prevent confusion when re wiring a DISCONNECT TOASTER FROM POWER SOURCE b Remove both side panels c Disconnect heater tube wires from the terminal blocks d Lift the heater tube retainer by loosening the screw and sliding the retainer up so that the holes line up e Gently pull the tube to be replaced out of the toaster f Gently s...

Page 5: ...en tighten the four mounting screws i Replace panels and test under power TROUBLESHOOTING GUIDE 1 UNIT WILL NOT HEAT CONVEYOR BELT WILL NOT MOVE a Check to make sure the toaster is PLUGGED IN b Check the control settings and make sure the Power Saver is in the FULL POWER 2 EITHER TOP OR BOTTOM HEATER TUBES DO NOT HEAT a Call the Belleco Inc service group at 1 877 854 8006 as one or more Heater Tub...

Page 6: ... 401202 Load Up Rack 1 400380 Conveyor Belt 1 201700 Drive Shaft 1 401340 Drive Sprocket 2 401300 Driven Shaft 1 401344 Drive Chain 1 401362 Speed Control 120V 1 200902 Fan Motor 120V 1 401209 Knob Speed Control 1 201800 Grill Air Intake 1 401220 Front Tension Spring 2 400261 Fan Motor Cord 1 401060 Legs 4 400300 Power Saver Switch 1 401103 Crumb Tray 1 300118 Knob Power Saver 1 201801 Power Cord ...