background image

Manual | EN

C6675

Industrial PC

2022-9-13 | Version: 1.0

Summary of Contents for C6675

Page 1: ...Manual EN C6675 Industrial PC 2022 9 13 Version 1 0 ...

Page 2: ......

Page 3: ... 17 3 3 Optional interfaces 18 3 4 Name plate 19 4 Commissioning 20 4 1 Transport and unpacking 20 4 2 Control cabinet installation 21 4 3 Connecting the industrial PC 23 4 3 1 Grounding of the industrial PC 23 4 3 2 Connecting cables and power supply 25 4 4 Switching the industrial PC on and off 26 5 Beckhoff Device Manager 27 6 Decommissioning 29 6 1 Disconnecting the power supply and cables 29 ...

Page 4: ...Table of contents C6675 4 Version 1 0 10 2 Approvals 47 ...

Page 5: ...The configurations depicted may deviate from the standard Trademarks Beckhoff TwinCAT TwinCAT BSD TC BSD EtherCAT EtherCAT G EtherCAT G10 EtherCAT P Safety over EtherCAT TwinSAFE XFC XTS and XPlanar are registered and licensed trademarks of Beckhoff Automation GmbH Other designations used in this publication may be trademarks whose use by third parties for their own purposes could violate the righ...

Page 6: ... injuries WARNING Disregarding the safety notice may lead to death or serious injuries CAUTION Disregarding the safety notice may lead to minor injuries Warning of damage to property NOTE Disregarding the notice may lead to damage to property 2 2 Intended use The ATX based industrial PC is designed for control cabinet installation and for use as a control system in machine and system engineering f...

Page 7: ...ations you must keep within the specified limits of power consumption and power loss please refer to the respective data sheet Ensure that only trained specialists with a control and automation engineering background operate the industrial PC Use by unauthorized persons can lead to damage to property and loss of data In case of fire extinguish the industrial PC with powder or nitrogen 2 4 Operator...

Page 8: ...orks The latter should be connected to the corporate network or the Internet only if appropriate protective measures have been set up In addition the recommendations from Beckhoff regarding appropriate protective measures should be observed Further information regarding information security and industrial security can be found in our https www beckhoff com secguide Beckhoff products and solutions ...

Page 9: ...ssors the industrial PC can be used for the following applications among others diverse automation and visualization tasks wide range of IoT tasks with data preprocessing complicated HMI applications extensive axis controllers short cycle times high volume data handling The basic configuration of the C6675 includes the following aspects ATX motherboard Intel processor 2 x DRAM SODIMM 3 inch hard d...

Page 10: ...oncept Holes for mounting the industrial PC in the control cabinet 2 Connection compartment Access to interfaces of the industrial PC 3 Name plate Information on the equipment of the industrial PC 4 Housing cover Access to exchangeable device components 5 Optional multi DVD drive Read and write CDs and DVDs 6 Two hard drive caddies Hard disks or SSDs ...

Page 11: ... the basic configuration the industrial PC includes the following interfaces Power supply X101 PS 2 mouse and keyboard X103 X104 USB X108 X111 Ethernet RJ45 X112 X113 DVI X114 X115 RS232 X116 DisplayPort X117 Audio connections X120 X122 Fig 2 C6675_connection section ...

Page 12: ...al PC The assignment includes a protective conductor 1 a neutral conductor 2 and an outer conductor 2 see Fig 3 X101 1 2 2 Fig 3 C6675_voltage socket 100 240 V 3 2 2 PS 2 The industrial PC has two PS 2 interfaces X103 X104 The upper interface X104 allows the connection of a PS 2 mouse the lower interface X103 allows the connection of a PC keyboard The connection is made via standard MiniDIN connec...

Page 13: ...CLK Mouse Clock 3 2 3 USB The industrial PC has four USB interfaces X108 X111 They are used to connect peripheral devices with USB interfaces 1 2 3 4 9 8 7 6 5 1 2 3 4 9 8 7 6 5 9 8 7 6 5 1 2 3 4 9 8 7 6 5 1 2 3 4 X109 X108 X111 X110 Fig 5 C6675_USB interface pin numbering Table 5 USB interface pin assignment Pin Connection Shield GND 1 Vbus 2 D 3 D 4 GND 5 StdA_SSRX 6 StdA_SSRX 7 GND_DRAIN 8 StdA...

Page 14: ... following distinction The Ethernet port X113 LAN2 connected via PCIe with the i210 controller is generally suitable for cycle times 1 ms and for distributed clock applications with EtherCAT The Ethernet port X112 LAN1 integrated in the chipset with the i219 controller is generally suitable for EtherCAT and real time Ethernet applications with cycle times 1 ms without distributed clocks 8 1 8 1 LA...

Page 15: ...d 13 not connected 21 not connected 6 DDC Clock 14 5V Power 22 TDMS Clock Shield 7 DDC Data 15 Ground 5 V Analog H V Sync 23 TDMS Clock 8 Analog Vertical Sync 16 Hot Plug Detect 24 TDMA Clock C5 GND 3 2 6 RS232 The serial interface COM1 X116 is fed out via a 9 pin standard DSUB connector The signals comply with the RS232 standard The port address and the used interrupt are configured automatically...

Page 16: ...is purpose C9900 Z468 adapter cable DisplayPort to DVI 40 cm 1 2 19 20 X117 Fig 9 C6675_DisplayPort pin numbering Table 10 Pin assignment of DisplayPort Pin Connection Pin Connection 1 LVDS lane 0 2 Ground 3 LVDS lane 0 4 LVDS lane 1 5 Ground 6 LVDS lane 1 7 LVDS lane 2 8 Ground 9 LVDS lane 2 10 LVDS lane 3 11 Ground 12 LVDS lane 3 13 Config 1 14 Config 2 15 AUX channel 16 Ground 17 AUX channel 18...

Page 17: ...nd microphone input X120 sockets X122 X121 X120 Fig 10 C6675_audio connections The three sockets are brought out for 3 5 mm jack plugs The pins of the jack plugs are assigned as follows L R GND Fig 11 C6675_jack plug pin assignment Table 11 Jack plug pin assignment Pin Connection L Left sound signal R Right sound signal GND Common ground return ...

Page 18: ...00 E210 Module to convert one serial RS232 interface of the motherboard into RS485 configured as an end point without echo D sub 9 pin overvoltage protection electrical isolation to be mounted inside the slot brackets C9900 M568 C9900 M569 or inside a C6640 C6650 at the connector bracket C9900 M751 A slot bracket is required C9900 E211 Module for conversion of a RS232 interface of the motherboard ...

Page 19: ...neration 4 Date of manufacture 5 Mainboard 6 CPU 7 Main memory 8 Power supply 9 MAC addresses of the Ethernet interfaces X112 X113 10 Storage media 11 Storage media 12 DVD drive 13 Optional interfaces 14 FCC approval 15 Note be sure to read the device manual 16 Symbols Note here are the symbols applicable to the device such as CE EAC UKCA The approvals of your device can be found on the name plate...

Page 20: ...riate packaging of the industrial PC in particular the original packaging can improve the vibration resistance during transport NOTE Hardware damage due to condensation Unfavorable weather conditions during transport can cause damage to the device Protect the device against moisture condensation during transport in cold weather or in case of ex treme temperature fluctuations Do not put the device ...

Page 21: ...ion can impair its functionality Mount the device only in the orientations shown in the documents The C6675 Industrial PC is designed for mounting in control cabinets in machine and plant engineering applications Please observe the environmental conditions prescribed for the operation see Chapter 9 Technical data 45 You can use the mounting concept see Fig 13 to mount the industrial PC in the cont...

Page 22: ...device dimensions of the PC see above You need M4 screws for mounting After you have drilled the holes for the fastening screws in the control cabinet you can mount the industrial PC in the control cabinet Fig 15 C6675_control cabinet installation To install the industrial PC in the control cabinet follow the steps below 1 Insert the fastening screws into the drill holes in the control cabinet 2 H...

Page 23: ... the low resistance protective earth of the industrial PC via the voltage connection thus avoiding dangerous touch voltages EMC NOTE Hardware damage due to electromagnetic interference Using the industrial PC without functional earthing can lead to hardware damage due to electromagnetic in terference Only use the device with functional earth Electromagnetic compatibility EMC of the industrial PC i...

Page 24: ...Commissioning C6675 24 Version 1 0 Fig 16 C6675_Grounding bolt for functional earthing ...

Page 25: ...via 100 240 VAC power supply unit For the connection of the power supply there is an IEC socket in the connection compartment on the top of the device To connect the industrial PC to the power supply use the supplied IEC power cable with a German Schuko plug at the end In the USA and Canada the connection cable must meet the following specifications depending on the power supply Separable supply c...

Page 26: ...ices in the PC yourself Please follow the instructions in the documentation for the operating system and the additional devices UPS software components To operate the power supply unit as a UPS the UPS software with the corresponding drivers must be installed on the industrial PC The software and drivers are already installed on delivery of the PC with operating system Otherwise you will have to i...

Page 27: ...using the Beckhoff Device Manager to remotely configure the Industrial PC via a web browser More detailed information is available in the Beckhoff Device Manager manual First start Beckhoff Device Manager When your Industrial PC is booted for the first time the Beckhoff Device Manager also starts automatically for the first time The Security Wizard opens This tells you that you should reset the de...

Page 28: ...words are an important prerequisite for a secure system Beckhoff supplies the device images with standard user names and standard passwords for the operating system It is imperative that you change these Controllers are shipped without a password in the UEFI BIOS setup Beckhoff recommends assigning a password here as well Please note the following Passwords should be unique for each user and servi...

Page 29: ...g a thunderstorm can lead to electric shock Never disconnect the cables from the device during thunderstorms Before you remove the industrial PC from the control cabinet you must follow the following steps 1 Shut down the operating system 2 Disconnect the industrial PC from the power supply see below 3 Disconnect the data transmission cables between the industrial PC and the connected devices see ...

Page 30: ...control cabinet ð You have successfully dismounted the industrial PC Fig 19 C6675_positions fastening screws Disposal of the industrial PC Be sure to observe the national electronic scrap regulations when disposing of the industrial PC In order to dispose of the device it must be removed and fully dismantled Dispose of the components in the following way Send plastic parts polycarbonate polyamide ...

Page 31: ...ing long term functionality Cleaning and maintenance of certain device components and the replacement of other device components contribute to this 7 1 Cleaning NOTE Unsuitable cleaning agents The use of unsuitable cleaning agents can damage the device Only clean the industrial PC as specified It is essential to observe the following aspects when cleaning the industrial PC Make sure that no dust g...

Page 32: ...on for replacement intervals years UPS battery pack 5 years 2 5 inch hard disk 5 years or after 20 000 operating hours at more than 40 C or after 30 000 operating hours at less than 40 C 3 5 inch hard disk 5 years irrespective of the operating hours Fan 7 years Compact Flash CFast or SSD 10 years Motherboard battery 5 years Beckhoff is excluded from liability in the event of possible damage occurr...

Page 33: ... the device against ESD damage For example the following measures can be used Use conductive mats connected to the ground potential as underlays Dissipate possible charges from your own body by touching grounded metal e g control cabinet door Wear a wrist grounding strap Only remove new electronic components from the ESD packaging tinted plastic bag after putting on the wrist grounding strap Do no...

Page 34: ...4 Loosen the knurled screw 2 of the card holder 3 section D 5 Remove the card holder from the housing ð You now have access to the interior of the industrial PC section E 1 2 3 A B C D E Fig 20 C6675_access device components To reinstall the card holder afterwards follow the steps below shown in Figure 21 1 Release all plastic elements of the card holder section A 2 Place the card holder again in ...

Page 35: ...75_hooks and guides To do this follow the steps below as shown in Figure 23 1 Hold the cover inclined and place it below the housing section A 2 Push the cover up as far as possible inserting the hooks of the cover into the guides of the housing 2 section B 3 Place the cover into a straight position against the housing until the release handle snaps back into place section C ð You have mounted the...

Page 36: ...Maintenance C6675 36 Version 1 0 A B C Fig 23 C6675_mounting housing cover ...

Page 37: ...t is used to supply power to the clock integrated on the motherboard If the battery is depleted or missing the date and time are displayed incorrectly Table 17 Technical data of the battery Battery type Electrical properties at 20 C Dimensions Nominal voltage Nominal capac ity Diameter Height Weight CR2032 3 0 V 225 mAh 20 0 mm 3 20 mm 3 1 g Chapter 7 2 1 Access to device components 34 shows how t...

Page 38: ...to the size of the backup copy of your operating system You can then keep the flash drive as a backup copy For this purpose the BST USB flash drives with SLC flash are designed for a particularly long data preservation For more information on the function of the BST please refer to the corresponding documentation If your storage medium is defective and there is no backup Beckhoff Service can provi...

Page 39: ...SD 1 Unlock the hard drive caddy with the corresponding key section A 2 Pull the key of the hard drive caddy to unlock it section B 3 Open the hard drive caddy section C 4 Pull the SSD out of the hard drive caddy by the protruding Beckhoff sticker section D 5 Reinsert the new SSD in the same orientation 6 Close the hard drive caddy again 7 Lock the hard drive caddy again ð You have replaced the SS...

Page 40: ...Maintenance C6675 40 Version 1 0 A B C D BECKHOFF Fig 26 C6675_exchange SSD ...

Page 41: ...nderside of the PC section A 2 Flip the cartridge down section B 3 Disconnect the supply cable of the fan from the motherboard 4 Remove the cartridge in the upward direction section C A B C Fig 27 C6675_exchange fan bottom 5 Insert the new fan cartridge 6 Connect the supply cable to the motherboard 7 Flip the cartridge up 8 Tighten the knurled screw ð You have now replaced the fan cartridge To rep...

Page 42: ...n A 2 Disconnect the supply cable of the cooler from the motherboard 3 Pull the cooler off the motherboard while pulling the locking elements out of the holes in the motherboard section B 4 Remove the residues of the old thermal compound from the surface of the CPU Use a paper towel moistened with alcohol for this purpose Avoid ESD damage by never using a textile cloth 5 Place the new cooler with ...

Page 43: ...Maintenance C6675 43 Version 1 0 A B Fig 29 C6675_exchange CPU cooler The old fan must be disposed of in accordance with the national electronic waste regulations ...

Page 44: ... PC Other cause Check the power supply cable Call Beckhoff Service The Industrial PC does not boot fully Setup settings are incorrect Other cause Check the setup settings Call Beckhoff Service Computer boots software starts but control does not operate correctly Cause of the fault is either in the software or in parts of the plant outside the Industrial PC Call the machine and software manufacture...

Page 45: ... 30 ms During reading of CD DVD 5 G approx 50 m s2 duration 11 ms EMC interference immunity conforms to EN 61000 6 2 EMC interference emission conforms to EN 61000 6 4 Permissible ambient temperature 0 C to 50 C operation 25 C to 65 C transport storage Permissible air humidity Maximum 95 no condensation Transport and storage The same values for air humidity and shock resistance are to be observed ...

Page 46: ...h can be found on the name plate Beckhoff Support Support offers you comprehensive technical assistance helping you not only with the application of individual Beckhoff products but also with other wide ranging services World wide support design programming and commissioning of complex automation systems extensive training program for Beckhoff system components Hotline 49 0 5246 963 157 Fax 49 0 5...

Page 47: ...These limits are designed to provide adequate protection against adverse interference if the device is used in a commercial environment This device generates uses and may emit radio frequency energy and may cause adverse interference with radio communications if it is not installed and used in accordance with the operating instructions If this device is used in a residential area it is likely to c...

Page 48: ...17 Fig 12 C6675_name plate 19 Fig 13 C6675_mounting concept 21 Fig 14 C6675_dimensions 22 Fig 15 C6675_control cabinet installation 22 Fig 16 C6675_Grounding bolt for functional earthing 24 Fig 17 Beckhoff Device Manager Change passwords 27 Fig 18 Beckhoff Device Manager Start page 28 Fig 19 C6675_positions fastening screws 30 Fig 20 C6675_access device components 34 Fig 21 C6675_mounting card hol...

Page 49: ...n device generation 14 Table 7 Ethernet interface pin assignment 14 Table 8 DVI interface pin assignment 15 Table 9 RS232 pin assignment 15 Table 10 Pin assignment of DisplayPort 16 Table 11 Jack plug pin assignment 17 Table 12 Interface options 18 Table 13 Module options 18 Table 14 Slot options 18 Table 15 Key C6675 name plate 19 Table 16 Replacement recommendations for PC components 32 Table 17...

Page 50: ......

Page 51: ...Beckhoff Automation GmbH Co KG Hülshorstweg 20 33415 Verl Germany Phone 49 5246 9630 info beckhoff com www beckhoff com More Information www beckhoff com c6675 ...