background image

R8-17...R30-17

Model: E22

en

Assembly and Operating Instructions

Tubular drives for roller shutters

Important information for:

• Fitters / • Electricians / • Users

Please forward accordingly!

These instructions must be kept safe for future reference.

Becker-Antriebe GmbH
Friedrich-Ebert-Straße 2-4
35764 Sinn/Germany
www.becker-antriebe.com

2010 301 266 0a     03/06/2022    

Summary of Contents for E22

Page 1: ...s for roller shutters Important information for Fitters Electricians Users Please forward accordingly These instructions must be kept safe for future reference Becker Antriebe GmbH Friedrich Ebert Straße 2 4 35764 Sinn Germany www becker antriebe com 2010 301 266 0a 03 06 2022 ...

Page 2: ... route 16 Assembling the drive 16 Assembling the drive adapter 16 Disassembling the drive adapter 17 Mounting the drive in the tube 17 Setting and deleting the limit positions for applications that represent a second escape route 18 Setting the limit positions using the programming unit 18 Deleting the limit positions using the programming unit 19 Adjusting the limit positions with a rotary switch...

Page 3: ...drive manufacturer s control units Please observe these Assembly and Operating Instructions when installing and setting up the equipment The date of manufacture comes from the first four digits of the serial number The numbers 1 and 2 indicate the year and the numbers 3 and 4 indicate the calendar week Example 34th calendar week in 2020 Ser No 2034XXXXX Explanation of pictograms CAUTION CAUTION in...

Page 4: ...y the drive manufacturer If any questions or uncertainties regarding the safety instructions contained in the standard arise please contact the manufacturer of the part or end product in question All applicable standards and regulations for electrical installation must be complied with All work including maintenance and cleaning on electrical installations as well as other system parts must always...

Page 5: ... down all lines and control devices that are not essential for op eration Crushing or shearing points must be avoided or protected When installing the drive all pole disconnection from the mains with a contact gap of at least 3 mm per pole must be provided EN 60335 If the mains connecting cable is damaged it may only be replaced by the manufacturer If the drive has a plug in connecting cable it mu...

Page 6: ...age The drive manufacturer does not accept liability for damages or injury arising from such actions Always observe the information in these instructions when operating or repairing the system The drive manufacturer does not ac cept liability for damage or injury resulting from improper usage Attention Only use anti lifting devices if the roller shutter laths are sufficiently strong The closed cur...

Page 7: ...ll bracket 2 The clear dimension of the box X minus the space required at the side M and idler G gives the length L of the barrel L X M G The space required at the side M varies depending on the combination of drive and wall bracket Then mount the wall bracket and idler Ensure that the barrel is aligned at right angles to the wall and that sufficient axial play is al lowed for the mounted system A...

Page 8: ...orque max Nm Fastening screws 4 units dia 35 dia 45 All Up to 50 Self tapping screw dia 4 8 x 9 5 mm We also recommend screwing the idler to the barrel Attention Do not hammer the tubular drive into the tube or drop it into the barrel The curtain can only be secured using springs or rigid shaft connectors We recommend at least three pieces per metre of barrel 2 1 Assemble the tubular drive with th...

Page 9: ...rrel so that the roller shutter curtain can be attached with springs or fit the rigid shaft connectors in accordance with the manufacturer s instructions Lay the connecting cable Lay the connecting cable up to the tubular drive and fix The connecting cable and any antennae must not project into the winding chamber Cover any sharp edges 9 en ...

Page 10: ...tes that no limit position has been set in that direction of movement There are 4 ways to set the limit positions Upper stop to lower stop Upper point to lower point Upper stop to lower point Upper point to lower stop Adjustment of the stop limit position must be complete before using the emergency crank handle see intelligent installation management If the tubular drive switches off prematurely w...

Page 11: ...o the permanent upper stop The tubular drive switches off automatically Then close to the desired lower limit position Press the programming button of the programming unit for 3 seconds The tubular drive acknowledges The limit positions are now set Upper point to lower stop Open to the desired upper limit position Press the programming button of the programming unit for 3 seconds The tubular drive...

Page 12: ... Also leave a pause of 1 sec between the individual steps of the deletion sequence black brown blue green yellow black brown blue green yellow Programming button Travel button Press the programming button and keep it pressed Then press down the travel button and keep it pressed Now release the programming button but continue to keep the travel button pressed Next press the programming button again...

Page 13: ...et the limit positions Upper stop to lower stop Upper point to lower point Upper stop to lower point Upper point to lower stop Adjustment of the stop limit position must be complete before using the emergency crank handle see intelligent installation management If the tubular drive switches off prematurely while opening or closing due to an obstruc tion the obstruction can be cleared by reversing ...

Page 14: ... Open to the permanent upper stop The tubular drive switches off automatically Then close to the desired lower limit position Carry out the following sequence without interruption between the individual drive commands The tubular drive acknowledges until STOP and hold until The limit positions are now set Upper point to lower stop Open to the desired upper limit position Carry out the sequence bet...

Page 15: ...g button The switching commands sequence must be carried out in quick succession Carry out the following deletion sequence without interruption between the individual drive commands until STOP The tubular drive acknowledges Both limit positions are deleted 15 en ...

Page 16: ... give the enclosed connection information to the responsible electrical contractor Calculate the space required at the side M by measuring the drive head 1 and wall bracket 2 The clear dimension of the box X minus the space required at the side M and idler G gives the length L of the barrel L X M G The space required at the side M varies depending on the combination of drive and wall bracket Then ...

Page 17: ...e ring and drive adapter are secure in the tube Mount the assembled unit comprising barrel tubular drive and idler on the box and secure the drive with a split or spring pin ac cording to the type of wall bracket fixing Automatic setting of limit positions is possible where a stop system is present on both sides using the rotary switch set Item no 4901 001 158 0 a standard rotary switch or the pro...

Page 18: ...es place dur ing regular operation To complete installation quickly it is sufficient to travel to the stop limit position 3 times in a row from approx 20 cm Limit position status indicator A brief stopping and restarting indicates that no limit position has been set in that direction of movement If the tubular drive switches off prematurely while opening or closing due to an obstruc tion the obstr...

Page 19: ... Also leave a pause of 1 sec between the individual steps of the deletion sequence black brown blue green yellow black brown blue green yellow Programming button Travel button Press the programming button and keep it pressed Then press down the travel button and keep it pressed Now release the programming button but continue to keep the travel button pressed Next press the programming button again...

Page 20: ...ubular drive has turned off automatically in the desired position three times Lower stop to upper stop Close to the permanent lower stop The tubular drive switches off automatically Then open to the permanent upper stop without pausing The tubular drive switches off automatically The limit positions are now set Deleting the limit positions with a rotary switch or a locking button The switching com...

Page 21: ...outputs of the switching element must be potential free in the neutral position Use external conductor L1 to control the up and down direction Other devices or consumers lamps relays etc must not be dir ectly connected to the drive connecting cables For this purpose the drives and additional devices must be decoupled by relay controls When installing the drive all pole disconnection from the mains...

Page 22: ...n continue in the desired direction Tubular drive is overloaded Use a higher torque tubular drive Delete limit positions then reprogram limit positions Tubular drive does not run in the right direction Tubular drive is overheated The tubular drive is operational again after a few minutes Tubular drive is faulty does not run even after standing still for a long period of time Replace the tubular dr...

Page 23: ...ack and brown wires according to the direction of travel is de pendant on how the drive is installed mounted to the right or to the left Controlling one several drive s via a single switch button Controls black brown blue green yellow Controls 23 en ...

Page 24: ...ual control using Centronic UnitControl UC42 Mains 230 V 50 Hz Central Group Individual Individual 230 V 50 Hz Central cable connection to further control units 230 V 50 Hz 230 V 50 Hz Electronics 230 V 50 Hz Control unit 24 en ...

Page 25: ...Declaration of conformity 25 en ...

Page 26: ...26 ...

Page 27: ...27 ...

Page 28: ......

Reviews: