IMPORTANT POINTS AND SAFETY
• Wiring the meter up to the network must be done by the person who has
knowledge about both technical and safety warnings.
• The meter parts which are carrying voltage must not be touched for any reasons,
electricity must be cut off while both wiring on and wiring off to the network.
• The outer surface of the meter must not be cleaned with cleaning agents
containing abrasives.
• The suitability of the meter type to be installed should be checked by authorised
personnel. Otherwise, your meter will be damaged due to incorrect meter selection
and connection. The meters in this case are out of guarantee.
• Calibration and programming of the meter are done during manufacturing.
Marketing is provided after each meter quality check. There is no maintenance or
programming that the user can do.
• BAYLAN Electronic Electricity Meters is a superior technology product in
compliance with world standards. All technical information and documents are in
the company's own Intellectual properties and copyright’s.
TECHNICAL SPECIFICATIONS
Model Name
BT.10
Meter Type
3-Phase, 4-Wire
Accuracy Class
B
Connection Type
Direct
Nominal Voltage (Un)
3x230/400 V
Operating Voltage Range
0,8 Un and 1,15Un
Reference Frequency
50 Hz ±%5
Starting Current (Ist)
20mA (0,04.Itr)
Minimum Current (Imin)
0,25 A
Transitional Current (Itr)
0,5 A
Nominal Current (In)
5 A
Maximum Current (Imax)
100 A
IP Rating
IP54 (Outside)
Protective Class
Two (2)
Humidity Ratio
Max. %95
Operating Temperature
-40
°
C, +70
°
C (3K7)
Mechanical Environment Class
M1
Electromagnetic Environment Class E2
Voltage Circuit Power Consumption < 2W, 10 VA
Current Circuit Power Consumption < 4 VA
Electrostatic Discharges
Contact discharge 8kV, air discharge 15kV
Impulse Voltage
6 kV
Meter Constant
1000 imp/kWh
LCD Display
6+3
Communication
Optical 300-19200 Baud (EN 62056-21)
Battery Life
≥ 10 year / 4 year
RTC Accuracy
<
0,5sec/day (EN 62054-21)
Standards
EN 50470-1, EN 50470-3
GENERAL FEATURES
• Eight different time zones can be set during the day and saved in one of four
different tariffs. It is possible to create different time zones and different tariffs for
4 different day types (weekdays, saturday, sunday and public holidays).
• Automatic daylight save implementation.
• Tariff informations, meter date and time, daylight saving time can be changed by
authorized personnel.
• If the top cover is opened, it records the opening date and time.
• If the terminal cover is opened, it records the first opening date for each month
and the total number of openings in that month. The last 12 months are stored in
memory.
• In the case of magnetic tampering, it records the start and end times.
• The meter records the consumed energy for each tariff in the last 12 months, the
maximum demand in the last 12 months and the date and time of the demand.
• Meter can record 8 channel load profile for period of 15 minutes for last 180
days. (Optional)
• The meter records the last 10 of voltage connection faults and current connection
faults.
• The meter records the start and end dates of the last 99 of short and long power
cuts.
LCD INFORMATION
Main menu
Information
Date information
Time information
Total energy consumption
Energy consumption during 1st Tariff
Energy consumption during 2nd Tariff
Energy consumption during 3rd Tariff
SPECIAL Energy consumption in the 4th Tariff *
Max. demand information
Max. demand date information
Max. demand time information
Obis code
0.9.2
0.9.1
1.8.0
1.8.1
1.8.2
1.8.3
1.8.4
1.6.0
1.6.0
1.6.0
Unit
day:month:year
hour:minute:second
kWh
kWh
kWh
kWh
kWh
kW
day:month:year
hour:minute
READING THE INFORMATION ON THE METER
• When the meter is powered, the main informations of the meter displayed
sequentally with 5 second periods. By pressing the button, the next information can be
switched quickly. If the button is pressed for 5 seconds, the meter screen switches to the
sub menu. Waits for the button to be pressed again to display the next information. If
the button is not pressed for 30 seconds or the button preesed for 5 seconds, meter
display returns to the main menu.
• When during power cuts, it is necessary to press the button to see the information on
the screen. Each press displays the next information.
• All the datas that the meter records and the datas which display on LCD can be read
from the meter with the communication interfaces. When during power cuts, the button
must be pressed to wake up the meter to read.
RTC Error
Low battery.
If the top cover is opened, it will flash on the screen and it will not be lost
under any circumstances.
If the terminal cover is open, it will be displayed continuously on the
screen. If it is flashing, it indicates that the terminal cover has already
been switched on and off.
Indicates the tariff slice.
T1 T2
T3 T4
The display shows which tariff consumption information is available.
RTC battery low.
Blinks during magnetic intervention. Continuous display on the screen
indicates that a magnetic interference has been made before.
It is visible during communication.
It shows the energized phases and current directions.
Indicates that information about the demand is displayed.
P
L1L2 L3
Units
HzVAkWh
BT.11
Three Phase Active Electronic Electricity Meter
User Manual
BAYLAN
ELECTRICITY METERS
BAYLAN ÖLÇÜ ALETLERİ SAN. ve TİC. LTD. ŞTİ.
Headquarters: A.O.S.B. 10032 Sk. No:16 Cigli - IZMIR / TURKEY
Production
: A.O.S.B. 10053 Sk. No: 6 Cigli - IZMIR / TURKEY
Tel: +90(232) 497 97 00
•
Fax: +90(232) 497 97 51 - 497 97 52 - 497 97 53
e-mail: [email protected]
•
web: www.baylanelektrik.com
YÖNETİM SİSTEMİ
BELGELERİMİZ
1783
Test
TS EN ISO/IEC 17025
AB-0177-T
Management
System
ISO 9001:2015
www.tuv.com
ID 9000004716